Double focussing magnetic sector

ScHRAMEL P and Wendler I (1998) Capabilities of double focussing magnetic sector-ICP-MS for the determination of trace elements in body fluids (blood, blood serum, urine) at the example of control materials. Fresenius Z Anal Chem 362 487-491. [Pg.1111]

Fig. 10.4 Scheme of a double-focussing magnetic sector instrument with BE configuration. Dependent on the mass-to-charge ratio the ions are distracted by the magnetic field to circular arcs with different radii. [Pg.336]

Double focussing magnetic sector mass analysers provide a very high reproducibility, high resolution, and a high dynamic range. Their use is limited due to their size and higher cost compared to other mass analysers. [Pg.337]

Hgure 7 Multielement speciation of MTs by FPLC coupled online to ICP-MS and UV-visible spectrometry. (Reprinted from Ferrarello CN, Fernandez de la Campa MR, Carrasco JF, and Sanz-Medel A (2000) Speciation of metallothionein-like proteins from the mussel Mytilus edulis at basal levels by chromatographic separations coupled to quadrupole and double focussing magnetic sector. ICP-MS. Analytical Chemistry 72 5874-5880.)... [Pg.1069]

GC-HRMS (double focussing magnetic sector instrument) 0.15... [Pg.2]

Figure 2.184 Principle of the double focussing magnetic sector mass spectrometer (reversed Nier Johnson geometry BE). Figure 2.184 Principle of the double focussing magnetic sector mass spectrometer (reversed Nier Johnson geometry BE).
Figure 2.191 The isotope pattern for 2,3,7,8-TCDD using a double focussing magnetic sector instrument with peak widths for resolutions of 1000 (a) and 10000 (b) (Furst and Berns-mann, 2010). Figure 2.191 The isotope pattern for 2,3,7,8-TCDD using a double focussing magnetic sector instrument with peak widths for resolutions of 1000 (a) and 10000 (b) (Furst and Berns-mann, 2010).
Analyzer type Double focussing magnetic sector MS... [Pg.705]

Walda, A. J. and Freedman, P. A. (1992) Isotopic ratio measuranent using a double focussing magnetic sector mass analyser with an inductively coupled plasma as an ion source. J. Aruil At. Spectrom., 7, 571—5. [Pg.67]

A schematic representation of a double-focussing mass spectrometer is shown in Fig. 10.4. For historical reasons, this set-up is referred to as a reverse-geometry magnetic sector mass spectrometer, which means that the magnetic sector precedes the electric sector [1]. [Pg.336]

Bartky and Dempster developed the theory for a double-focussing mass spectrometer with electrostat and magnetic sector. [Pg.4]


See other pages where Double focussing magnetic sector is mentioned: [Pg.277]    [Pg.79]    [Pg.65]    [Pg.277]    [Pg.79]    [Pg.65]    [Pg.35]    [Pg.83]    [Pg.46]    [Pg.83]    [Pg.440]    [Pg.42]   