Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Digestion time

Comparative studies were performed to evaluate microwave digestion with conventional sample destmction procedures. These included the analysis of shellfish, meats, rocks, and sods. Generally, comparable accuracy at much shorter digestion time was found for the MAE vs the classical digestion method (39). [Pg.242]

Digestion time before neutralization/hydrolysis Digestion temperature... [Pg.664]

RDF products from El —> E3 have got high chlorine content in comparison with that of other RDF (see Table 9). In this experiment, digesting time was noticed by the leachate volume. But in R1 —> R3, waste was taken out of bio-box when water content was stable in around 6 weeks. [Pg.453]

Figure 5. Influence of digestion time and temperature on extraction yield. Coal = Beynon solvent = anthracene oil coal solvent ratio = 1 4. Figure 5. Influence of digestion time and temperature on extraction yield. Coal = Beynon solvent = anthracene oil coal solvent ratio = 1 4.
Figure 6. Influence of digestion time on the extraction yield and yield of filter cake. Digestion Annesley coal/hydrogenated solvent prepared at 430°C (— —), yield of filter cake (------------------), extraction yield. Figure 6. Influence of digestion time on the extraction yield and yield of filter cake. Digestion Annesley coal/hydrogenated solvent prepared at 430°C (— —), yield of filter cake (------------------), extraction yield.
The combination of proteolytic enzyme digestion and heat-based treatments has been reported however, this increases the susceptibility of the tissues for disintegration. Significant shortening of the digestion time and reduction of the enzyme concentration should be undertaken when testing such protocols. Furthermore, reproducible proteolytic enzyme treatments require optimal conditions for individual tissues, which make these protocols difficult to perform. [Pg.92]

This protocol can be nsed as a fu-st-mn attempt at tissue disaggregation. Fnrther experience with the tissue will probably yield insights as to the best enzyme types, enzyme concentration, digestion time, and digestion temperature. [Pg.259]

Selection of digestion time By means of the time switch, at the left ftont comer, the time interval per digestion zone can be set at ftom 2 to 60 minutes. Multiplying this by live gives the total digestion time for transporting the vessels through the VAO. [Pg.31]

With this programme, the vessels reach a maximum temperature of 270°C at zone four. The total digestion time would be 3S minutes. Applications include measurement of total recoverable metals in waste water and the measurement of trace metals in air filters. [Pg.31]

Thus, it delays carbohydrate digestion, prolongs digestion time and reduces the rate of glucose absorption thereby lowering postprandial hyperglycemia. [Pg.280]

Seven factors (three acid volumes, digestion time, predigestion, temperatures and sample weight) ruling two wet digestion procedures were developed and optimised... [Pg.104]

Ashing temperature, digestion time and amount of reagents were studied by experimental designs to prevent volatilisation of organic P compounds present in minor concentrations in polymer materials... [Pg.110]

High-yield chemical pulps can be produced by the soda, kraft, or sulfite processes, in which chemical use and digestion time and/or temperature are suitably reduced to effect a milder cook than used for full chemical pulps. Mechanical defibrators are used to complete the separation of wood fibers not accomplished by the chemical action... [Pg.1380]

Torres et al. [342] found that a microwave-assisted robotic method for trace metals in soil decreased sample digestion times from two hours to three minutes. [Pg.68]

Microwave digestion time Microwave the samples for 5 min Microwave the samples for 7 min Acceptance criteria... [Pg.170]

Modern microwave digestion systems monitor both pressure and temperature in the containers. As the temperature or pressure reaches the set point, power to the oven is cut. The oven power as well as the maximum pressure and temperatures can be set. Both digestion time and oven power can be programmed so that each sample is treated in a reproducible manner. The initial digestion is done slowly at low temperature, and the temperature is increased after the majority of the readily digested matrix is dissolved. [Pg.234]


See other pages where Digestion time is mentioned: [Pg.703]    [Pg.768]    [Pg.282]    [Pg.2192]    [Pg.510]    [Pg.264]    [Pg.603]    [Pg.127]    [Pg.127]    [Pg.243]    [Pg.445]    [Pg.445]    [Pg.258]    [Pg.152]    [Pg.360]    [Pg.74]    [Pg.75]    [Pg.34]    [Pg.66]    [Pg.66]    [Pg.66]    [Pg.166]    [Pg.1379]    [Pg.1627]    [Pg.106]    [Pg.111]    [Pg.112]    [Pg.279]    [Pg.64]    [Pg.65]    [Pg.68]    [Pg.30]    [Pg.237]   
See also in sourсe #XX -- [ Pg.153 ]




SEARCH



© 2024 chempedia.info