Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Differential thermal analysis systems DuPont

Resin Analysis. Thermal analysis of the BCB resin systems included Differential Scanning Calorisietry (DSC) using a DuPont 010 cell and Thermal Gravimetric Analysis (TGA) run on a DuPont 951 TGA, the entire thermal analysis system run using an Omnitherm model 35053... [Pg.368]

Fig. 1 Schematic diagrams of the (A) differential thermal analysis (DTA) (B) power-compensated DSC and (C) heat-flux DSC cells. (From Ref adapted from DuPont Instruments Systems Brochure.)... Fig. 1 Schematic diagrams of the (A) differential thermal analysis (DTA) (B) power-compensated DSC and (C) heat-flux DSC cells. (From Ref adapted from DuPont Instruments Systems Brochure.)...
DuPont supply a dual sample pressure differential calorimetry cell suitable for use in their 9900 thermal analysis system. [Pg.397]

DuPont also supply a model 930 differential photocalorimeter in their 9900 Thermal Analysis system and Perkin Elmer supply the DSC-7 instrument. [Pg.409]

Thermal analysis of polymers was performed on DuPont Model 910 Differential Scanning Calorimeter and a Perkin Elmer Model TQS-2 Thermal Gravimetric Analyzer using a heating rate of 10°C/min. Both systems were interfaced to an Omnitherm Data Station for experiment control, and data acquisition and processing. [Pg.225]

Instrumental. All Differential Scanning Calorimetry (DSC) runs were conducted on a Perkin-Elmer DSC-7 attached through a TAC-7 Thermal Analysis Controller to a DEC computer station 325c. All runs were conducted at 10°C/min. in N2 unless otherwise stated. Thermogravimetry was run on a Perkin Elmer TGA-7 attached through the same system as the DSC. Isothermal aging of samples in sealed capillaries were conducted in the DSC cell of a DuPont 9(X) Thermal Analyzer after temperature calibration. [Pg.170]

Differential scanning calorimetry and thermal mechanical analysis data were obtained on a DuPont 990 thermal analyzer coupled with a DuPont DSC or TMA cell. Isothermal aging studies were carried out with an automatic multisample apparatus, which allowed weight loss to be obtained in the aging environment. Thermal mechanical data for all the systems prepared are listed in Table I. [Pg.32]


See other pages where Differential thermal analysis systems DuPont is mentioned: [Pg.276]    [Pg.108]    [Pg.101]    [Pg.137]    [Pg.339]    [Pg.329]   
See also in sourсe #XX -- [ Pg.349 ]




SEARCH



Differential analysis

Differential system

Differential thermal analysis systems

Thermal Analysis System

Thermal systems

© 2024 chempedia.info