Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Diameter hydraulic, valve

A, free diameter of the connection to the chamber B, cylindrical opening by the movement of D C, opening between condenser wall and valve plate D, valve plate, hydraulic valve drive E, condensation surface of the refrigerated coils F, in- and outlet of the refrigerant G, tube connection to the vacuum pump H, water drain during defrosting of the condenser pch and pm pressure in the chamber and in the condenser, respectively. [Pg.144]

Decomposition Flame Arresters Above certain minimum pipe diameters, temperatures, and pressures, some gases may propagate decomposition flames in the absence of oxidant. Special in-line arresters have been developed (Fig. 26-27). Both deflagration and detonation flames of acetylene have been arrested by hydraulic valve arresters, packed beds (which can be additionally water-wetted), and arrays of parallel sintered metal elements. Information on hydraulic and packed-bed arresters can be found in the Compressed Gas Association Pamphlet G1.3, "Acetylene Transmission for Chemical Synthesis. Special arresters have also been used for ethylene in 1000- to 1500-psi transmission lines and for ethylene oxide in process units. Since ethylene is not known to detonate in the absence of oxidant, these arresters were designed for in-line deflagration apphcation. [Pg.2060]

FIGURE 3.29 A schematic view from above the disk of a passive capillary burst valve. A liquid flows in a channel or capillary and is pinned at the discontinuity where the channel meets a chamber or a wider channel. Sufficient fluidic pressure must be exerted by the centrifugal pump to overcome the pressure of curved liquid surfaces and to wet the walls of the chamber with liquid. This pressure is achieved at a characteristic rate of rotation or burst frequency, C0c, above which the liquid exits the channel and enters the chamber. CO, depends on the hydraulic diameter (dH) of the capillary and the amount of liquid in the channel and therefore provides a means of gating the flow of liquid [1042]. Reprinted with permission from the American Chemical Society. [Pg.84]

Tray layout. The preliminary tray and downcomer layout is prepared in the column-sizing phase and refined during the hydraulic design phase. In addition to the parameters previously set, such parameters as hole diameter or the type of valve unit are determined. [Pg.25]

Figure 10-4. French pressure cell alone (a) and assembled into a hydraulic press (b). Diameter of the orifice through which cells pass may be adjusted using the valve located on the side of the pressure cell. This instrument accommodates sample volumes between 4 and 50 ml by lowering or raising the piston, respectively. The piston is raised to its maximum position in the cell that is assembled in the press and is completely lowered in panel (a). (Courtesy of American Instrument Company, Silver Spring, Md.)... Figure 10-4. French pressure cell alone (a) and assembled into a hydraulic press (b). Diameter of the orifice through which cells pass may be adjusted using the valve located on the side of the pressure cell. This instrument accommodates sample volumes between 4 and 50 ml by lowering or raising the piston, respectively. The piston is raised to its maximum position in the cell that is assembled in the press and is completely lowered in panel (a). (Courtesy of American Instrument Company, Silver Spring, Md.)...
Micromixer-tube reactor plants have been employed both at laboratory and pilot-scale [30]. For initial process development, a triangular ( focusing ) interdigital micromixer was used (Fig. 6.18), while for the pilot scale-out a caterpillar mixer was connected to four tubes of different hydraulic diameter by a five-port valve. [Pg.101]

Studies were made at room temperature (27°C) of the continuous countercurrent extraction of catalytic reformate with sulfolane and with 1,3-dicyanobutane. In this study a 22-stage, 1 inch diameter York-Scheibel extraction column was used. The hydrocarbon mixture was introduced into the bottom of the column, and the polar solvent was introduced at the top of the column. The effluent streams emerged just beyond the feed points. The streams were metered into the column under a hydraulic head plus 2 psi of air from reservoirs through needle valves and calibrated rotameters. The stream rates were well below flooding... [Pg.256]


See other pages where Diameter hydraulic, valve is mentioned: [Pg.129]    [Pg.418]    [Pg.376]    [Pg.296]    [Pg.498]    [Pg.320]    [Pg.521]    [Pg.167]    [Pg.259]    [Pg.1196]    [Pg.141]    [Pg.232]    [Pg.76]    [Pg.79]    [Pg.178]    [Pg.282]    [Pg.132]    [Pg.167]    [Pg.231]    [Pg.15]    [Pg.338]    [Pg.508]    [Pg.267]    [Pg.209]    [Pg.136]    [Pg.158]    [Pg.158]    [Pg.8]    [Pg.210]    [Pg.1064]    [Pg.14]    [Pg.155]    [Pg.86]    [Pg.306]    [Pg.211]   
See also in sourсe #XX -- [ Pg.282 ]




SEARCH



Hydraulic diameter, valve unit

Valve hydraulic

© 2024 chempedia.info