Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Density gradients materials

The density of some materials may be found using a density gradient column. This is a cylinder containing liquid layers of varying densities, with the most dense at the bottom of the column and the least dense at the top. A sample to be determined is placed in the column and falls to the level that is similar to its density. [Pg.438]

Method Density gradient, Rate-zonal Gradient 10-40% continuous sucrose Rotor/run conditions SW 55 Tl rotor at 55000 rpm for approximately 6 hours Potential tube materials Polyallomer, Ultra-Clear... [Pg.303]

Method Density gradient. Rate-zonal. The rate-zonal method is one of six addressed by SpinPro. The other methods are differential, differential-flotation, discontinuous, isopycnic, and 2-step isopycnic. These methods differ dramatically in their set up, principles of operation, and expected results. The rate-zonal method is described here briefly so that the recommendations to follow can be appreciated. Prior to the run in a rate-zonal method, a gradient material is introduced to the rotor tubes in steps of increasing density from the top to the bottom of the tube. The sample to be separated is layered, as a thin band, on the top of the gradient. As the run begins, each component in the sample moves toward the bottom of the tube. Some components sediment faster than others. This fact is the basis for the separation. If the run parameters are appropriate, the components will form separate bands within the gradient. At the conclusion of the run, the band representing the component of interest can be removed from the tube. [Pg.304]

Density gradients maybe divided into three types preformed discontinuous gradients (e.g.. Protocol 5.3.1), preformed continuous gradients (e.g.. Protocol 5.3.2) or self-generating gradients (e.g.. Protocol 5.3.3). Materials used for density gradients are classified as ionic and non-ionic media (Table 5.1). [Pg.165]

Quiescent Solutions. Coulometry at constant current provides a simple method for measuring the quantity of electrogenerated species as long as the reaction proceeds with 100% current efficiency. However, this condition breaks down with depletion of the electroactive material in the diffusion layer (cf. chronopotentiometric transitions see Fig. 4.3). For low values of the applied current, the thermal and density gradients supplement diffusion sufficiently to sustain electrolysis without the potential shifting to a different reaction. This mode of radical generation has been employed successfully in the study of stable species. [Pg.936]

In dilatometry, specific volumes V or densities of materials are measured by use of a pycnometer, dilatometer, or density-gradient column. The data obtained are then interpreted through the equation... [Pg.37]


See other pages where Density gradients materials is mentioned: [Pg.197]    [Pg.460]    [Pg.197]    [Pg.197]    [Pg.460]    [Pg.197]    [Pg.2767]    [Pg.281]    [Pg.407]    [Pg.257]    [Pg.308]    [Pg.452]    [Pg.311]    [Pg.422]    [Pg.375]    [Pg.398]    [Pg.863]    [Pg.383]    [Pg.160]    [Pg.30]    [Pg.256]    [Pg.98]    [Pg.200]    [Pg.329]    [Pg.162]    [Pg.162]    [Pg.610]    [Pg.611]    [Pg.281]    [Pg.407]    [Pg.8]    [Pg.531]    [Pg.534]    [Pg.1537]    [Pg.195]    [Pg.384]    [Pg.495]    [Pg.1516]    [Pg.195]    [Pg.262]    [Pg.233]    [Pg.401]    [Pg.327]    [Pg.390]    [Pg.58]   
See also in sourсe #XX -- [ Pg.339 ]




SEARCH



Material densities

Materials gradient

© 2024 chempedia.info