Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Decreasing detection times

Increasing metabolism is probably the most effective way to decrease the time period that drugs can be detected in your system. Metabolism can be influenced by physical activity, diet, and drugs. [Pg.17]


O, a large current is detected, which decays steadily with time. The change in potential from will initiate the very rapid reduction of all the oxidized species at the electrode surface and consequently of all the electroactive species diffrising to the surface. It is effectively an instruction to the electrode to instantaneously change the concentration of O at its surface from the bulk value to zero. The chemical change will lead to concentration gradients, which will decrease with time, ultimately to zero, as the diffrision-layer thickness increases. At time t = 0, on the other hand, dc-Jdx) r. will tend to infinity. The linearity of a plot of i versus r... [Pg.1929]

Experimentally, it is sometimes difficult to detect differences between a shear-thinning Hquid in which the viscosity decreases with increasing shear, and a thixotropic material in which the viscosity decreases with time, because of the combined shear and time effects that occur during a series of measurements. This is especially tme if only a few data points are collected. In addition, most materials that are thixotropic are also shear thinning. In fact. [Pg.168]

The soil analysis is presented in Table II. Small amounts of 2,4-D and 2,4,5-T were detected in soil samples receiving these herbicides. Background values from the control soils were subtracted from the observed values in treated soils. The samples were not corrected for recovery since it was better than 80% for the method. Residues decreased with time after application. Leaching and microbial decomposition could account for this observation. [Pg.114]

Cherry and Crandall in 1932 (86) used olive oil as substrate with gum acacia as the emufsTfier. This method has served as the basis for a number of modifications that increased the stability of the emulsion, decreased incubation time and gave better precision. When a serum sample is incubated with a stabilized olive oil emulsion, lipase acts at the interface of substrate and water to hydrolyze olive oil into fatty acid plus diglycerides, and to a small extent to monoglycerides and glycerol. The bile salt sodium deoxycholate activates the reaction. These methods measure the liberated fatty acids by titration with a standardized NaOH solution. An indicator such as phenolphatalein, thymolphthalein or methyl red or a pH meter are used to detect the end point. [Pg.213]

It has been established that methane is produced on rice roots by reduction of CO2. This was examined in rice roots using a combination of 16S rRNA sequencing and density gradient fractionation of C-labeled DNA after incubation with C02. The major groups of archaea detected were Methanosarcinaceae that decreased with time to be replaced by the hitherto uncultured Rice Cluster I, although the former subsequently dominated (Lu et al. 2005). [Pg.628]

The rotation speed provides an independent variable increasing to decreases the time taken for a species to travel between the disc and the ring and hence increases the likelihood of detecting a short-lived intermediate. All of the above methods critically depend on the species generated at the electrode being active towards further electron transfer at the ring. [Pg.186]

The rate of step 4 involving elimination of halosilane also depends on the nature of the halogen atom but in the inverse order F < < Br. For Hal=Br, intermediates (32) are impossible to detect. By contrast, for Hal=F, elimination of Si F is the rate-determining step, which requires a special procedure, for example, refluxing of intermediate (32) (Hal=F) in acetonitrile for 1 h. (Preliminary data show that the microwave technology makes it possible to sharply decrease the time required for completion of step 4 (90)). A decrease in the elimination rate in the series F < < Br is evidence that this reaction is not... [Pg.458]

The time resolution of stopped flow experiments is typically 1-2 ms,21 and is determined by the time required to mix the solutions, flow the mixed solution to the detection chamber, and stop the flow. Smaller detection cells can be used to decrease the time resolution at the expense of the signal-to-noise ratio of the detected signals. Various kinetic traces have to be averaged to achieve good kinetic profiles and sample volumes of milliliters with concentrations of micromolar to millimolar are required. [Pg.171]

For the statistical analysis, the Hllcoxon Paired-Sample Test was used. A test for a one-tailed hypothesis with paired samples was used In the procedure for nonparametrlc data since It could not be assumed that the levels of residue detected were from a normal distribution and It was expected that the residues would decrease with time. [Pg.175]

The modification of chromatographic properties, unlike in GC, is usually of secondary importance. Often, however, a lowering of the polarity of certain molecules (e.g., sugars) is observed which enables the separation on adsorption chromatographic systems with more convenient solvent systems. This in turn may decrease retention times and consequently improve detection limits. [Pg.2]


See other pages where Decreasing detection times is mentioned: [Pg.17]    [Pg.17]    [Pg.17]    [Pg.17]    [Pg.266]    [Pg.299]    [Pg.65]    [Pg.330]    [Pg.173]    [Pg.150]    [Pg.108]    [Pg.153]    [Pg.23]    [Pg.110]    [Pg.209]    [Pg.365]    [Pg.64]    [Pg.907]    [Pg.518]    [Pg.47]    [Pg.335]    [Pg.303]    [Pg.16]    [Pg.180]    [Pg.98]    [Pg.135]    [Pg.1335]    [Pg.67]    [Pg.201]    [Pg.322]    [Pg.173]    [Pg.116]    [Pg.246]    [Pg.189]    [Pg.17]    [Pg.94]    [Pg.110]    [Pg.563]    [Pg.70]   


SEARCH



Decrease

Decreasing

Detection time

© 2024 chempedia.info