Current Noise pick

The main problem has been a methodological one. The patch clamp analysis of single channels views the world of channels through a very small analytical window [10]. A single channel event (opening) needs to be sufficiently long-lived and sufficiently large to be picked up within the current noise band under optimized conditions, and with the low-pass filter set to say 2 kHz. The open time needs to be close to a millisecond and the current amplitude close to 0.5 pA to permit detection. [Pg.277]

Internal sources of noise arise from any power-dissipating device. Of course, every laboratory apparatus is a potential source of contamination. For example, Johnson noise arises because the electrons that carry an electric current always have a thermal motion, causing small fluctuating voltages across any resistor in the electrical circuit. One source of environmental noise is the "pick-up" of a 50-Hz signal due to the main supply in the laboratory. [Pg.86]

The rule-of-thumb is to pick an output capacitor with a ripple current rating equal to or greater than the worst-case RMS capacitor current calculated above. Its voltage rating is usually picked to be at least 20 to 50% higher than what it will see in the application (i.e. Vin.max for all topologies). The input voltage ripple of the converter is also usually a concern because a small part of it does get transmitted to the output. There can also be EMI considerations involved. In addition, every control IC has a certain (usually unspecified) amount of input noise and ripple rejection, and it may misbehave if the ripple is too much. Typically, the input ripple needs to be kept down to less than 5% to 10% of the input... [Pg.124]

M KCl solution placed in another chamber, a sb spanning over the two chambers. For a two-electrode system as is usually used in the measurement, the newly cut tip of the metallic wire, coated with absorbed lipids, acts as the WE. The current through the s-BLM is measured in the auxiliary electrode during the CV. The setup is housed in a Faraday cage to minimize interference by external noise and electrical transients. In spite of shielding, external noise may still be picked up by the switch box therefore, for the critical measurements the switch box should be incorporated within the same Faraday shield as the cell. All cables used are shielded and the shields are grounded. [Pg.445]

The pick-up of electrical and electromagnetic noise should be avoided, especially in the case of the application of electrochemical pulse methods and sensitive dc measurements involving small potential perturbations and currents. [Pg.21]

PU electrode situated on an inactive skin site. The other electrode is then situated on an active skin site. This constitutes a monopolar system. If both electrodes are situated on an active skin site, no signal (potential difference) is measured. Function is independent of surface area (as are all PU electrodes), but small electrodes pick up more noise. Not CC, current density J = 0. Indifferent electrode shall be situated far from bioelectric sources. Examples ECG right leg, other extremities, Wilson terminal. EEG ear flip, nose. Electrodermal activity elbow. [Pg.227]

The recordings in Figs. 10.19 and 10.20 were obtained by averaging a large number of fast sweeps. In this way the detrimental influence of atmospheric turbulence, etc. can be eliminated, as in doas measurements. If the optical absorption is very small an increased signal-to-noise ratio can be obtained if a modulation teclmique is employed. If the modulation frequency imposed on the diode-laser drive current is low compared to the absorption linewidth, the driver wavelength is modulated and the signal can be picked up by a lock-in amplifier as illustrated in Fig. 10.21a. The technique is referred to... [Pg.410]


See other pages where Current Noise pick is mentioned: [Pg.106]    [Pg.298]    [Pg.319]    [Pg.136]    [Pg.78]    [Pg.89]    [Pg.152]    [Pg.205]    [Pg.225]    [Pg.247]    [Pg.122]    [Pg.29]    [Pg.46]    [Pg.90]    [Pg.63]    [Pg.74]    [Pg.137]    [Pg.190]    [Pg.210]    [Pg.232]    [Pg.422]    [Pg.244]    [Pg.401]    [Pg.63]    [Pg.74]    [Pg.137]    [Pg.190]    [Pg.210]    [Pg.232]    [Pg.381]    [Pg.382]    [Pg.149]    [Pg.73]    [Pg.280]    [Pg.292]    [Pg.346]    [Pg.212]    [Pg.985]    [Pg.466]    [Pg.317]    [Pg.186]    [Pg.293]    [Pg.117]   