Testing cryogenic

This test is mostly specified by end users and design engineers, and mimics the well-documented cryogenic tests usually done on control valves and other line valves. [Pg.268]

The equipment used consisted of two plates mounted on an Instron testing machine, with gasket deflection measured by an extensometer driven by an appropriate linkage. For cryogenic testing, the entire fixture was immersed in liquid nitrogen. A number of modulus values for various materials are shown in Table II. Note the excellent values obtained for the fluorocarbon polymer-112 glass laminate. [Pg.142]

While Centaur upper stages continue to be used for evolved expendable launch vehicles (EELV), start baskets were never installed into the propellant tanks. Several low-g CFM experiments were proposed (Chato, 2006) and modifications to convert the Centaur upper stage into a cryogenic test bed were conceived, but they never came to fruition (Kutter et al., 2006 Sakla et al., 2006 Gravlee et al., 2010). [Pg.40]

Testing was performed at the CCL-7 at GRC. The exact same three samples from room temperature tests were used for cryogenic tests here. A LAD screen sample is shown in Figure 5.1. Screen samples were cut, mounted, and welded to a heavy flange with a... [Pg.112]

Jurns, J.M., Kudlac, M.T., 2006. NASA Glenn Research Center creek road complex - cryogenic testing facilities. Cryogenics 46, 98-104. [Pg.438]

Paynter, H.L., 1973a. Acquisition/expulsion system for earth orbital propulsion system, volume IB, cryogenic test. MCR-73-97, NASA-CR-134155, Martin Marietta Corporation, Denver, CO. [Pg.445]

The work of H, L. Johirston s group at Ohio State University, the cryogenic tests of NACA, and the publications of NBS were most helpful. We also particularly wish to thank R, B, Scott, R, B, Jacobs and other members of the NBS staff for their many practical suggestions in this project. [Pg.253]

Tills electronics scheme has been demonstrated to work on the bench at room temperature to the level described above (see figure IX.F.2). Further tests are in progress to finalize details for optimizing the performance of this electronics set-up at liquid hydrogen temperatures. The cryogenic test vessel mentioned above will have signal leads added to facilitate these tests. [Pg.117]

The test core was installed in a heat transfer test rig, which was constructed as shown schematically in Fig. 8, The test rig is part of The Garrett Corporation Cryogenic Test Facility, which is located in the Mojave Desert near Boron, Cal. The apparatus was a double closed-loop system, in which helium was circulated at about 50 to 250 psia in one loop, and normal hydrogen was circulated at about... [Pg.249]

Fig. 14. Cryogenic testing of dielectric parameters and breakdown voltage. Fig. 14. Cryogenic testing of dielectric parameters and breakdown voltage.

See other pages where Testing cryogenic is mentioned: [Pg.484]    [Pg.484]    [Pg.13]    [Pg.123]    [Pg.279]    [Pg.161]    [Pg.269]    [Pg.217]    [Pg.381]    [Pg.388]    [Pg.509]    [Pg.85]    [Pg.205]    [Pg.230]    [Pg.371]    [Pg.474]    [Pg.82]    [Pg.4]    [Pg.173]   
See also in sourсe #XX -- [ Pg.256 ]