Crucible holder

Schmelztiegel, m. crucible, melting pot. -deckel, m. crucible cover (Metal.) tile, -halter, m. crucible holder, crucible support, -zange, /. crucible tongs. [Pg.392]

Cone. This type of crucible shape (Fig. 8 c) provides an increased contact area between crucible and its counterpart on the crucible holder. Especially in the combination TG-DTA this decreases the thermal resistance and allows a better resolution of the measured DTA-effect. [Pg.83]

The other end of the capillary tube carries a plug type connector which allows the crucible holder to be rapidly removed and replaced. The connector is adjustable with a centering device. [Pg.93]

In a power compensation DSC (figure 12.3), the sample and the reference crucible holders consist of two small furnaces, As and Ar, each one equipped with a temperature sensor, Bs or Br, and a heat source, Cs or Cr. The furnaces... [Pg.172]

Walter crucible holder Balance (to 1 microgram) Tweezers... [Pg.86]

In the field, a rotameter connected to the crucible holder is used to monitor flow rates each day. We recently Invested in a direct-reading rotameter with a range of 3-21 Lpm, and we anticipate better recognition of flow problems during sampling surveys. [Pg.95]

The apparatus consists of a 500-ml. round-bottomed flask A (Fig. 1) equipped with a single side arm bearing a 250-ml. separatory funnel B and with an inverted sintered-glass filter funnel C. The latter is held in place by a gum-rubber Gooch crucible holder D and is inserted into an... [Pg.4]

Figure 37-18. Types of crucible holders, (A) Inner Funnel. (B) Bailey. (C), Filtervac. (D) Walter s. Figure 37-18. Types of crucible holders, (A) Inner Funnel. (B) Bailey. (C), Filtervac. (D) Walter s.
Filter crucibles are used with a crucible holder mounted on a filtering flask (Figure 2.22). A safety bottle is connected between the flask and the aspirator. [Pg.48]

After completing the analysis, clean the crucibles as follows. Remove the cake of silver chloride, then place the crucibles in a beaker, put about 5 mL concentrated ammonia solution in each crucible, and cover the beaker with a watch glass. After 10 to 15 min, transfer the crucible to the crucible holder in a suction flask and wash with several portions of distilled water. If the filter plate is dark, empty and rinse... [Pg.732]


See other pages where Crucible holder is mentioned: [Pg.77]    [Pg.93]    [Pg.94]    [Pg.112]    [Pg.116]    [Pg.95]    [Pg.773]    [Pg.531]    [Pg.152]    [Pg.773]    [Pg.531]    [Pg.547]    [Pg.773]    [Pg.246]    [Pg.48]    [Pg.731]    [Pg.33]    [Pg.847]    [Pg.791]    [Pg.97]    [Pg.28]    [Pg.399]    [Pg.421]    [Pg.525]   
See also in sourсe #XX -- [ Pg.48 ]