Iris, coupling

Figure 6.3 The Mark II cavity spectrometer viewed through its Perspex cover. The spatial filter is visible in the centre of the case. The translation stage and piezoelectric actuator are seen in the foreground and operate via the bellows to move the near mirror. The coupling iris is in the centre of the far mirror. The waveguide couplings holding the mica vacuum windows can be seen either side of the case in the background. Sample inlet is on the left wall of the case not visible and outlet is on the right via the pressure sensor... Figure 6.3 The Mark II cavity spectrometer viewed through its Perspex cover. The spatial filter is visible in the centre of the case. The translation stage and piezoelectric actuator are seen in the foreground and operate via the bellows to move the near mirror. The coupling iris is in the centre of the far mirror. The waveguide couplings holding the mica vacuum windows can be seen either side of the case in the background. Sample inlet is on the left wall of the case not visible and outlet is on the right via the pressure sensor...
For the transmission cavity considered here, some power will always be coupled out through the output coupling iris. If we call Pp the power reflected from the input to the cavity, then... [Pg.238]

With )% = 2 = 1 one ninth of the input power is reflected and four ninths each is dissipated in the load and in the cavity. Also for this case, Qq = Qcl = Qc2 Ql = (l/3)9o- In order to have no power reflected from the input coupling iris, 1 + = 0. [Pg.238]

Microwaves from the waveguide are coupled into the resonator by means of a small coupling hole in the cavity wall, called the iris. An adjustable dielectric screw (usually machined from Teflon) with a metal tip adjacent to the iris pennits optimal impedance matching of the cavity to the waveguide for a variety of samples with different dielectric properties. With an appropriate iris setting the energy transmission into the cavity is a maximum and simultaneously reflections are minimized. The optimal adjustment of the iris screw depends on the nature of the sample and is found empirically. [Pg.1560]

Poor yields are obtained in the coupling of rirt/iri-substituted arylboronic acids[506). Ba(OH) as a base gives good results for the coupling of these sterically hindered compounds[5l3], but unsatisfactory results are observed... [Pg.219]

FIGURE 2.6 X-band rectangular waveguide. Dimensions of the waveguide (left) dimensions of the coupling hole (middle) and picture of the coupling hole with the iris screw (right). [Pg.20]

Check coupling (by power variation) and optionally adjust the iris (to power-invariant bias). [Pg.26]

FIGURE 2.8 Tuning mode patterns. The scope mode shows a dip when the frequency of the microwave fits into the resonator. This dip has maximal depth when the spectrometer is tuned (with the adjustable iris) to be reflectionless, that is, when the resonator is critically coupled to the bridge. Shown patterns are (a) off resonance, (b) slightly off resonance, (c) either under- or over-coupled, (d) critically coupled, (e) asymmetry from out-of-phase reference. [Pg.26]

M. Irie, T. Terada, T. Katsura, S. Matsuoka, and K. Inui. Computational modelling of H+-coupled peptide transport via human PEPT1. J Physiol 565 429-439 (2005). [Pg.571]

Powder X-ray diffraction (XRD) data were collected via a Siemens D5005 diffractometer with CuKa radiation (A. = 1.5418 A). Routine transmission electron microscopy (TEM) and Z-contrast microscopy were carried out using an HITACH HD-2000 scanning transmission electron microscope (STEM) operated at 200 kV. Nitrogen gas adsorption measurements (Micromeritics Gemini) were used to determine the surface area and porosity of the catalyst supports. Inductively coupled plasma (ICP) analysis was performed via an IRIS Intrepid II XSP spectrometer (Thermo Electron Corporation). [Pg.58]

These values are currently under review by EPA and have not been included in the IRIS (1998) database. It is not likely, based on the potential for human exposure data presented in Chapter 5, coupled with the NOAELs and LOAELs gathered from human case reports and laboratory animal studies, that levels of 1,4-dichlorobenzene in the drinking water in any location would be high enough to cause a concern for cancer in humans. [Pg.146]

The above hardware was used to create at NASK a multimodal biometric database BioBase, which at present contains images of iris, face, hand shape, and handwritten signatures, of couple of hundred volunteers. BioBase will be employed here to test the proposed approaches. [Pg.261]

Pockels cell I, beam limiting iris S, slit C, sample cell HG, holographic grating (polychromator) CCD, charge coupled device (light detection array). All optical elements are constructed from fused silica, or designed to be transparent to 200 nm. From ref. [13]. [Pg.28]

Still, in many cases photoderacemization of racemic mixtures has been successful. Irie et al. announced [54] the detection of the effect, but a detailed study of this system was published only as a patent [55] in CH2CI2 solutions of 1,l -binaphthyl they found values of [a]345 =-JX75-and 4- 0.7 for 1- and r-cpl with a 270-300 nm band of a 500 W Xe source at room temperature in ca. 5 min. Here two aromatic units are connected by a single bond. These systems are realizations of Kuhn s coupled oscillator model of optical activity [56]. The steric overlap provides chirality, ground state enantiomerization has AIv 92 kJ mol 1 [57], and the triplet state enantiomerizes fast, with 8 kJ mol 1. [Pg.15]

The mechanism of the reaction involves initial formation of a Iri-organocopper intermediate, followed by coupling and loss of RCu. The coupling is not a typical polar nucleophilic substitution reaction of the sort considered in the next chapter. [Pg.347]

The chemical shifts as well as the coupling constants Jh,i5n iri the bases, and related compounds have not been interpreted theoretically. On the other hand, the magnitude of the coupling constants has been predicted from the molecular structure with reasonable accuracy by means of CNDO/2 calculations for pyrimidine, pjnridine, or pyra-zole. We can expect that a similar prediction of the spin-spin coupling constants may be made for the pyrimidine and purine nucleic acid bases. [Pg.335]

We may subsume all of the complexity of the full electromagnetic wave description of the Gaussian beam and its coupling to various elements of the resonator into two phenomenological constants the mutual inductances M, and M2 of Fig. 6. This procedure is equivalent to that used to model variable iris coupling into a waveguide cavity, for example. [Pg.288]

The best ratios in favor of the S M2 -coupled products are obtained in Et20 (no indications about the syn /iri-stereochemistry was reported). [Pg.486]

Niiro derivatives of 2 5,8-tripheny -iris triazolobenzene (XI) are very interest ing heal resistant compounds (52). The substances were obtained by coupling diazoii/ed iiitroanilines w ilh 1,3,5 triaminobenzene, followed by oxidation with C uSOa. C ompounds from/vnitroaniline and 2.4-diniiroaniline had in.ps of 370 C and 400 ( tcspecUvely. [Pg.470]


See other pages where Iris, coupling is mentioned: [Pg.372]    [Pg.923]    [Pg.582]    [Pg.15]    [Pg.35]    [Pg.40]    [Pg.582]    [Pg.236]    [Pg.240]    [Pg.264]    [Pg.320]    [Pg.372]    [Pg.923]    [Pg.582]    [Pg.15]    [Pg.35]    [Pg.40]    [Pg.582]    [Pg.236]    [Pg.240]    [Pg.264]    [Pg.320]    [Pg.588]    [Pg.412]    [Pg.15]    [Pg.21]    [Pg.13]    [Pg.80]    [Pg.122]    [Pg.97]    [Pg.18]    [Pg.79]    [Pg.840]    [Pg.219]    [Pg.344]    [Pg.27]    [Pg.581]    [Pg.583]    [Pg.709]    [Pg.496]    [Pg.691]   
See also in sourсe #XX -- [ Pg.15 , Pg.35 , Pg.40 ]