Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Coupling guards

For pumps above 25 hp, flexible disk, spacer-type couplings should be u 1 The flexible elements must be selected for compatibility with the plant atmosphere. For the smaller systems, a non-spacer coupling may be adequate, but the coupling should be of good quality. This is not the place to /e money. Coupling guards should be furnished as a part of the lube tern. [Pg.312]

Figure 12-150. This standard arrangement 8 cast iron (C.l.) E blower, with motor and coupling factory mounted, is fitted with optional flanged inlet and outlet and coupling guard. (Used by permission Bui. FI-411C (11/90), 1988. The Howden Fan Co.)... Figure 12-150. This standard arrangement 8 cast iron (C.l.) E blower, with motor and coupling factory mounted, is fitted with optional flanged inlet and outlet and coupling guard. (Used by permission Bui. FI-411C (11/90), 1988. The Howden Fan Co.)...
TYPE OF COUPLING GUARD DRIVER HALF COUPLING FITTED BY 36... [Pg.995]

Removable coupling guards shall be furnished and shall be in accordance with requirements of applicable national, industrial, or statutory bodies. [Pg.45]

Shaft coupling assembly drawing and bill of materials including allowable misalignment tolerances and the style of the coupling guard. ... [Pg.161]

Each coupling shall have a coupling guard which is removable without disturbing the coupled elements and shall meet the following requirements ... [Pg.73]

ROTATION L.8. SHAFT FACING DRIVER COUPLING GUARDS ... [Pg.690]

Adjustment. Means for external adjustment (without disassembly of the pump except for die coupling guard) of the impeller axial clearance shall be provided if adjustment is required by the design. [Pg.14]

Coupling Guard Non-Spark CP G N SP c 1 liyes (true) Oino (false)... [Pg.35]

P062 Coupling Guard Baseplate Mounted CG BP MNT c 1 1 yes(true) 0 no(false)... [Pg.37]

Vertical Inline Close-coupled Coupling Guard Type ... [Pg.42]

Coupling Guard Inspection Required for Connection Welds ... [Pg.42]

The use of guard columns or precoliunns also falls into the category of column coupling. Guard columns are highly recommended for samples that contain... [Pg.341]


See other pages where Coupling guards is mentioned: [Pg.320]    [Pg.165]    [Pg.450]    [Pg.13]    [Pg.479]    [Pg.86]    [Pg.196]    [Pg.73]    [Pg.169]    [Pg.70]    [Pg.1007]    [Pg.691]    [Pg.466]    [Pg.23]    [Pg.42]    [Pg.45]    [Pg.133]   
See also in sourсe #XX -- [ Pg.320 ]




SEARCH



Couplings and Guards

Guard, guards

© 2024 chempedia.info