Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Control Structure for Reactor-Column Process

The reactor effluent F is flow-controlled. This is the production rate handle. [Pg.139]

Reactor level is controlled by manipulating the fresh feedstream FA0. This is selected because the concentration of A in the reactor is large (CA = 1.706 kmol/m3). Perfect level control is assumed, so the flowrate FA0 is calculated by subtracting the volumetric flowrates of FB0 and Dvoi from Fvol. [Pg.139]

Reactor temperature TR is controlled by manipulating jacket cooling water flow Fj. [Pg.139]

Sr integration loop while timectstop t Colunn Level controller  [Pg.139]


See other pages where Control Structure for Reactor-Column Process is mentioned: [Pg.139]   