Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Conductivity units probes

Two major sources of ultrasound are employed, namely ultrasonic baths and ultrasonic immersion hom probes [79, 71]- The fonuer consists of fixed-frequency transducers beneath the exterior of the bath unit filled with water in which the electrochemical cell is then fixed. Alternatively, the metal bath is coated and directly employed as electrochemical cell, but m both cases the results strongly depend on the position and design of the set-up. The ultrasonic horn transducer, on the other hand, is a transducer provided with an electrically conducting tip (often Ti6A14V), which is inuuersed in a three-electrode thenuostatted cell to a depth of 1-2 cm directly facing the electrode surface. [Pg.1942]

Thus electrical conductivity is commonly measured in units of S/cm (0 cm ). Various experimental methods have been used to measure the electrical conductivity of conductive polymers, eg, 4-probe method. Van der Pauw method, etc, and are well documented in the Hterature. [Pg.42]

The first experiments with the thermal electric engine were conducted in Russia in 1929 by its inventor, Valentin P. Glushko, who later became a world-famous authority in rocket propulsion. For more than forty years, the United States and Russia have devoted many resources to research and development of various kinds of EREs. First tested in space by the Russians in 1964, these engines have found some limited applications in modern space technology. For more than two decades Russian weather and communication satellites have regularly used electric rocket engines for orbital stabilization. The first spacecraft to employ ERE for main propulsion was the American asteroid exploration probe Deep Space 1, launched in 1998. The performance of... [Pg.1076]

Plug the conductivity probe into the adapter cable in channel 1 of the CBL unit. [Pg.14]

Using the 100-mL graduated cylinder, measure 70 mL of distilled water into the 150-mL beaker. Raise the beaker until the conductivity probe is in the water. After the conductivity meter stabilizes, press TRIGGER on the CBL unit. [Pg.14]

Volumetric Metering. This unit is employed where volumes exceeding the capacity of the automatic pipets are desired. Liquid flowing into the unit rises until it contacts a prepositioned probe. The contact probes are for electrically conducting liquids. Capacitance-sensitive probes are available for nonconducting or inflammable liquids. A number of liquids may be admitted in sequence by employing multiple probes and valves. [Pg.335]

This trend is nicely revealed by the ET distance dependence studies carried out on the SAMs of unsaturated bridges shown in Fig. 24. The /3 value for ET mediated by the saturated polymethylene bridge, determined from conducting probe atomic force microscopy, is 0.94 A-1 (Fig. 24a).121 (/3 for this system is also given in Fig. 19e, but in units of bond-1 all /3 values listed in Fig. 24 are in A-1 units because they were reported in this form in the literature.). A similar /3 value of 0.90 A-1 was... [Pg.45]

Conductivity type, single-probe unit. 350 two probes with dflierenlial conhol. 630. [Pg.813]


See other pages where Conductivity units probes is mentioned: [Pg.916]    [Pg.151]    [Pg.151]    [Pg.209]    [Pg.315]    [Pg.178]    [Pg.241]    [Pg.271]    [Pg.383]    [Pg.154]    [Pg.472]    [Pg.149]    [Pg.44]    [Pg.226]    [Pg.15]    [Pg.548]    [Pg.395]    [Pg.46]    [Pg.133]    [Pg.67]    [Pg.133]    [Pg.365]    [Pg.297]    [Pg.210]    [Pg.245]    [Pg.78]    [Pg.584]    [Pg.365]    [Pg.326]    [Pg.287]    [Pg.212]    [Pg.98]    [Pg.813]    [Pg.110]    [Pg.259]    [Pg.315]    [Pg.224]    [Pg.2744]    [Pg.258]    [Pg.2342]   
See also in sourсe #XX -- [ Pg.99 , Pg.100 ]




SEARCH



Conductance units

Conductivity units

© 2024 chempedia.info