Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Conductivity, thermal, data

Thermal Conductivity. Thermal conductivity data for transparent vitreous silica are listed below (150) ... [Pg.506]

Figure 1. Scaled thermal conductivity (k) data for several amorphous materials is shown. The horizontal axis is temperature in units of the Debye temperature Tjj. The vertical axis scale K = The value of To is somewhat uncertain, but its choice made by Freeman and... Figure 1. Scaled thermal conductivity (k) data for several amorphous materials is shown. The horizontal axis is temperature in units of the Debye temperature Tjj. The vertical axis scale K = The value of To is somewhat uncertain, but its choice made by Freeman and...
Fig. 10. Sonochemical rates as a function of ambient gas thermal conductivity. [Replotted data from R. O. Prudhomme (95).]... Fig. 10. Sonochemical rates as a function of ambient gas thermal conductivity. [Replotted data from R. O. Prudhomme (95).]...
Jamieson, D. T. Irving, J. B. Tudhope, J. S. "Liquid Thermal Conductivity, A Data Survey to 1973" Her Majesty s Stationery Office, Edinburgh, 1975. [Pg.485]

Jamieson, D.T., Irving, J.B., and Tudhope, J.S., Liquid Thermal Conductivity A Data Survey to 1973, Her Majesty s Stationary Office, Edinburgh, 1975. [Pg.327]

D. T. Jamieson, J. B. Irving, andj. S. Tudhope, Eiquid Thermal Conductivity A Data Survey to 1973, National Engineering Laboratory, Edinburgh, Scodand, 1975. [Pg.192]

In later PR-TRMC measurements, the after-pulse relaxation of the microwave conductivity itself in pure gases was monitored with nanosecond time-resolution and this provided a more detailed, quantitative method of monitoring electron thermalization. Of particular importance was a detailed study of thermalization in helium, which could be used to test the predictions of different theoretical treatments for this well-characterized gas. Detailed thermalization data were also obtained for oxygen, for which the concurrent three-body attachment process provides an interesting complication. The dramatic influence of small concentrations of water vapor on the thermalization process was also demonstrated for samples of dry and humid air. ° The (unexpectedly) high thermalization... [Pg.165]

Once this initial characterization has been completed, continuation of the microscopic analysis using the hot-stage accessory may proceed. As an initial analysis, the ramp rate utilized for the DSC experiment should also be used for the hot-stage analysis. Use of a consistent ramp rate permits direct comparison of the data previously collected by DSC and TGA. If transitions are observed in the thermal data up to 300°C, the hot-stage experiment should also be run to that temperature. Ultimately, the assay should be conducted to generate confirmatory data on all transitions of interest. If available, the color camera should be utilized so that images may be collected as documentation of the transitions observed. Once the experiment is completed, the analyst may be able to compare the DSC, TGA, XRD, optical, and HSM data and develop a comprehensive characterization of the material. [Pg.243]

Kingery, W. O., Franch. J., Coble, R. L.. and Vasilos, T., Thermal conductivity X. data for several pure oxide materials corrected to zero porosity./ Am. Ceram. Soc.. 37.2. 107. 1954. [Pg.2617]

FIGURE 4.6 Distribution of thermal conductivity values (data from Table 4.5). [Pg.87]

The reliability of the metal/polymer bond under moist thermal cycling, moist and dry thermal environments, and simulated soldering conditions was examined. Similar data for 30 % glass-filled polyetherimide have been presented previously Table X displays the cycling and thermal data. As can be seen in the table, the metal/polymer bond was extremely durable. Simulated soldering experiments were conducted on polyetherimide film pretreated with nitric acid as the impregnator. liiis material has a glass-transition temperature of 216 C and a continuous use temperature of ISS C. [Pg.306]

First, heat exchanger heat balance calculations are conducted in a flowsheet simulation software, which has adequate thermal data and can describe process streams according to their physical properties and operating conditions. By providing measured temperatures, the simulation can determine the heat transfer duty from Q = m Cp AT. At the same time, the simulation calculates transfer capability by lumping overall heat transfer coefficient and surface area together as U - A = 2/ATlm> where ATlm is defined in equation (6.7) in Chapter 6. [Pg.120]

It is difficult to calculate thermal conductivity of oriented filled polymers, all the more to ascertain the temperature dependence of thermal conductivity ( ), thermal diffusivity (a), and specific heat (c). The calculation formulae cannot allow for such phenomena as the glass-transition of polymers, the possible lamination of polymer films due to the great discrepancy between the coefficients of linear expansion of the binder and filler, the effect of multiple thermal loading, etc. Therefore, most valuable are the experimental data on thermophysical properties of composite polymers in a wide temperature range (between 10 and 400 K). [Pg.309]

The properties required for thermal stress analysis Included Young s modulus, Poisson s ratio, thermal conductivity, thermal expansion coefficient and specific heat. The CARES analysis requires strength data (from which the Weibull parameters are calculated) and Poisson s ratio. Fracture toughness was also measured. Although this parameter is not required for the fast fracture prediction made by CARES, it 1s used in life-time prediction and is related to the properties used in the reliability analysis. Strength measurements, which are the basis of reliability predictions, are controlled by both the size of flaws inherent in ceramic materials and the fracture toughness. Toughness represents the ability of a material to tolerate flaws. [Pg.383]


See other pages where Conductivity, thermal, data is mentioned: [Pg.150]    [Pg.392]    [Pg.171]    [Pg.1]    [Pg.94]    [Pg.44]    [Pg.345]    [Pg.150]    [Pg.164]    [Pg.352]    [Pg.820]    [Pg.473]    [Pg.731]    [Pg.494]    [Pg.675]    [Pg.469]    [Pg.248]    [Pg.238]    [Pg.664]    [Pg.212]    [Pg.437]    [Pg.303]    [Pg.542]    [Pg.229]    [Pg.378]    [Pg.153]    [Pg.215]    [Pg.554]   
See also in sourсe #XX -- [ Pg.170 ]

See also in sourсe #XX -- [ Pg.166 ]

See also in sourсe #XX -- [ Pg.170 ]

See also in sourсe #XX -- [ Pg.170 ]




SEARCH



Conductivity, thermal, data packed beds

Effective-thermal-conductivity Data

© 2024 chempedia.info