Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Computational fluid dynamics membrane reactor

For ease of fabrication and modular construction, tubular reactors are widely used in continuous processes in the chemical processing industry. Therefore, shell-and-tube membrane reactors will be adopted as the basic model geometry in this chapter. In real production situations, however, more complex geometries and flow configurations are encountered which may require three-dimensional numerical simulation of the complicated physicochemical hydrodynamics. With the advent of more powerful computers and more efficient computational fluid dynamics (CFD) codes, the solution to these complicated problems starts to become feasible. This is particularly true in view of the ongoing intensified interest in parallel computing as applied to CFD. [Pg.411]

Thus, expectedly no rigorous mathematical models are available that can accurately describe the detailed flow behavior of the fluid streams in a membrane separation process or membrane reactor process. Recent advances in computational fluid dynamics (CFD), however, have made this type of problem amenable to detailed simulation studies which will assist in efficient design of optimal membrane filtration equipment and membrane reactors. [Pg.488]

Takeuchi et al. 7 reported a membrane reactor as a reaction system that provides higher productivity and lower separation cost in chemical reaction processes. In this paper, packed bed catalytic membrane reactor with palladium membrane for SMR reaction has been discussed. The numerical model consists of a full set of partial differential equations derived from conservation of mass, momentum, heat, and chemical species, respectively, with chemical kinetics and appropriate boundary conditions for the problem. The solution of this system was obtained by computational fluid dynamics (CFD). To perform CFD calculations, a commercial solver FLUENT has been used, and the selective permeation through the membrane has been modeled by user-defined functions. The CFD simulation results exhibited the flow distribution in the reactor by inserting a membrane protection tube, in addition to the temperature and concentration distribution in the axial and radial directions in the reactor, as reported in the membrane reactor numerical simulation. On the basis of the simulation results, effects of the flow distribution, concentration polarization, and mass transfer in the packed bed have been evaluated to design a membrane reactor system. [Pg.33]

Any notable accumulation of gas was unlikely since the two fans inside the chassis create a flow rate of approximately 180 CFM of air through the system. This corresponded to more than 95 complete air changes or turnovers every minute (Heck and Manning, 2000). The most likely zone of gas escape would be above the microreactor due to a membrane failure. If this occurs, the control system should have interlocked and shutoff the flow of combustible gas to that reaction channel. The flammable gas that does escape would have been immediately diluted by air flowing over the microreactor at an estimated rate of 120 ft min (Heck and Manning, 2000). To provide a more detailed analysis of gas mixing in the immediate vicinity of a microreactor die, a computational fluid dynamics (CFD) model was constructed to simulate the gas flow hydrodynamics. This simulation quantifies that there is a recirculation zone above the reactor with an airflow rate... [Pg.387]

With pervaporation membranes the water can be removed during the condensation reaction. In this case, a tubular microporous ceramic membrane supplied by ECN [124] was used. The separating layer of this membrane consists of a less than 0.5 mm film of microporous amorphous silica on the outside of a multilayer alumina support. The average pore size of this layer is 0.3-0.4 nm. After addition of the reactants, the reactor is heated to the desired temperature, the recyde of the mixture over the outside of the membrane tubes is started and a vacuum is apphed at the permeate side. In some cases a sweep gas can also be used. The pressure inside the reactor is a function of the partial vapor pressures and the reaction mixture is non-boiling. Although it can be anticipated that concentration polarization will play an important role in these systems, computational fluid dynamics calculations have shown that the membrane surface is effectively refreshed as a result of buoyancy effects [125]. [Pg.248]

Computational fluid dynamics (CFD) analysis of membrane reactors simulation of single- and multi-tube palladium membrane reactors for hydrogen recovery... [Pg.464]


See other pages where Computational fluid dynamics membrane reactor is mentioned: [Pg.224]    [Pg.239]    [Pg.568]    [Pg.564]    [Pg.25]    [Pg.50]    [Pg.942]    [Pg.464]    [Pg.532]    [Pg.714]    [Pg.264]   
See also in sourсe #XX -- [ Pg.466 ]




SEARCH



Computation fluid dynamics

Computational fluid

Computational fluid dynamics

Dynamics, reactors

Fluid dynamics

Fluid membrane

© 2024 chempedia.info