Traditionally, column efficiency or plate counts in column chromatography were used to quantify how well a column was performing. This does not tell the entire story for GPC, however, because the ability of a column set to separate peaks is dependent on the molecular weight of the molecules one is trying to separate. We, therefore, chose both column efficiency and a parameter that we simply refer to as D a, where Di is the slope of the relationship between the log of the molecular weight of the narrow molecular weight polystyrene standards and the elution volume, and tris simply the band-broadening parameter (4), i.e., the square root of the peak variance. [Pg.585]

In gas phase chromatography, separations can be so complex that it is difficult to assess whether the temperature should be decreased or increased. The choice of the column, its length, its diameter, the choice of the stationary phase and of the phase ratio are all parameters that can have an impact on the separation. Furthermore, all of these parameters can affect each other. [Pg.19]

The chromatographic equipment which is responsible for the separation includes the pump, and in many systems a column oven. The parameters which affect the separation are the flow rate, the solvent composition and the LC gradients. Many different software packages are available which allow completely unattended automatic chromatography. Such systems also include control of the sample injection process. [Pg.34]

Before attempting a preparative mixture separation by column chromatography, you must always analyse the mixture by TLC to establish the stationary phase and solvent parameters for effective separation and to determine the R values of the components. [Pg.217]

Relative retentions..the a values..usually vary Inversely with column temperature, but are most strongly affected by the choice of liquid phase. In packed column chromatography, the choice of liquid phase Is usually the most effective route by which separation efficiency Is Influenced. In capillary GC, however, there Is normally such an abundance of theoretical plates that the choice of liquid phase Is a relatively unimportant parameter for many analyses. In some cases however. It does become desirable (or even necessary) to select a liquid phase in which the relative retentions of certain solutes Is larger. Until quite recently, this posed a real problem with the fused silica capillary column, because the more polar liquid phases, l.e. those In which relative retentions are usually greater, coated fused silica only reluctantly, and produced columns whose useful lives were quite limited. The development of stable bonded phase columns ( ) eventually overcame this difficulty (vide Infra). [Pg.30]

Diamines. Chromatography has been used to isolate three isomers of trans- and cis-[Co(CN)2 (RR)-cyclohexane-l,2-diamine 2] and five isomers of the corresponding propylenediamine complexes. Mer- and /ac-isomers of tris(meso-pentane-3,4-diamine)cobalt(iii) have been prepared and separated using column chromatography. The rates of aquation of three isomers of [CoCl(tmd)(dien)] and one isomer of [CoCl(tmdXdpt)] have been measured and the kinetic parameters calculated [dpt = NH2(CH2)3NH(CH2)3NH2, tmd = NH2(CH2)3NH2]. The interaction of [Co(dien)2] with sulphate, thiosulphate, sulphite, selenite, tellurite, and carbonate ions has been studied potentiometrically and stability constants determined for the outer-sphere complexes. The i.r. spectrum of octahedral... [Pg.237]

Quantitation may be done crudely on the spots separated by planar chromatographic techniques such as TLC or slab gel electrophoresis (see Chapter 13). One might compare the optical density, the fluoresence, or the degree of stationary phase fluoresence suppression by the unknown spot to a series of standards of known concentration. In contrast, the electrical signals from the variety of detectors used in various column chromatography instruments can be precisely, reproducibly, and linearly related to the amount of analyte passing through the detector cell. If all parameters of injection, separation, and detection are carefully controlled from run to run, and especially if appropriate quantitative internal standards are incorporated in the procedure, accuracy and precision better than +1 % may be attained. [Pg.740]

In order to design the appropriate liquid chromatography separation system, it is necessary to nnderstand on molecular level some basic principles and tendencies of the processes taking place in the chromatographic column. Above processes resnlt in differences in retention of sample constituents to allow their mutual separation. Extent of retention of macromolecules within colutim reflects the volume of mobile phase needed for their elution, their abovementioned retention volume, V. For the sake of simplicity, let us consider constant overall experimental conditions that is the elnent flow rate, temperature and pressure drop. The latter two parameters are dictated not only by the inherent hydrodynamic resistance of colunm that is inflnenced by the eluent viscosity, size and shape of packing particles but also by the sample viscosity, which may be rather high in polymer HPLC. Further, only one variable molecular characteristic of separated macromolecules will be... [Pg.246]


See other pages where Column chromatography separation parameters is mentioned: [Pg.108]    [Pg.24]    [Pg.173]    [Pg.231]    [Pg.234]    [Pg.206]    [Pg.3]    [Pg.320]    [Pg.64]    [Pg.37]    [Pg.120]    [Pg.522]    [Pg.102]    [Pg.135]    [Pg.143]    [Pg.31]    [Pg.72]    [Pg.703]    [Pg.468]    [Pg.198]    [Pg.1172]    [Pg.268]    [Pg.46]    [Pg.348]    [Pg.560]    [Pg.135]    [Pg.994]    [Pg.152]    [Pg.39]    [Pg.510]    [Pg.518]    [Pg.812]    [Pg.594]    [Pg.57]    [Pg.45]    [Pg.34]    [Pg.72]    [Pg.287]    [Pg.520]    [Pg.468]    [Pg.1449]   