Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Collimated radiation

The linear and nonlinear optical responses for this problem are defined by e, 2, e and respectively, as indicated in figure Bl.5.5. In order to detemiine the nonlinear radiation, we need to introduce appropriate pump radiation fields E(m ) and (co2)- If these pump beams are well-collimated, they will give rise to well-collimated radiation emitted tlirough the surface nonlmear response. Because the nonlinear response is present only in a thin layer, phase matching [37] considerations are unimportant and nonlinear emission will be present in both transmitted and reflected directions. [Pg.1277]

There are many methods of X-ray topography, though the most popitlar are the Lang method with slit-collimated radiation and the double-crystal methods, which may be thought of as high resolution diffractometry with an imaging... [Pg.10]

Fig. 4 Different optochemical configurations for flow-cell-based sensors. Notice that flow cells are expendable. S source, D detector, Of optical fiber, a Non-guided sensors the transmission of a non-guided collimated radiation beam is measured, b Radiation is guided though optical fibers from the source to the recognition element and from this position to the detector... Fig. 4 Different optochemical configurations for flow-cell-based sensors. Notice that flow cells are expendable. S source, D detector, Of optical fiber, a Non-guided sensors the transmission of a non-guided collimated radiation beam is measured, b Radiation is guided though optical fibers from the source to the recognition element and from this position to the detector...
The spatial distribution also strongly depends on the initial energy (longitudinal) of the electrons. If we consider that the electron has an initial energy, the component px of the momentum is increased, which directly results in more strongly collimated radiation. Numerical simulations show that elec-... [Pg.217]

Brede HJ, Hecker O, Hollnagel R. (2000) An absorbed dose to water calorimeter for collimated radiation fields. Nuclear Instruments and Methods in Physics Research AA55 3y. 721-732. [Pg.252]

Radiation losses are reduced with a well collimated radiation beam, as orthogonality between the incident beam and any interfaces results in less pronounced refraction. Regarding flow analysis, transient liquid/liquid interfaces that are oblique to the incident beam can be established inside the flowing sample and this is related to occurrence of the Schlieren effect [3]. This effect is more pronounced in spectrophotometers with inferior optical components and design. [Pg.98]

Analogously to spectrophotometry, a cuvette containing the processed sample, traversed by a collimated radiation beam (Fig. 4.1), is utilised in turbidimetry. If some of the radiation is scattered, the power of the incident light beam (Pi) is decreased to Pe, the power of the emergent beam, and Eq. 4.1 holds, providing that turbidance is considered instead of absorbance. [Pg.109]

The frequency of the energetic forklift collision after a roil down the truck ramp, as developed by the event tree analysis, is consistent with the hazard evaluation in most cases vwth the event tree analysis assessing frequency the same or one level less often. The collimated radiation beam, high dose rate, and airborne release outcomes are produced by the cask lid opening or coming off in a forklift crash. [Pg.180]

The sensitivity of AAS measurements can be increased significantly by increasing the absorption pathlength. A very effective multipass system can be achieved if the collimated radiation of a tunable laser is used as the primary light source. If the absorbing medium is placed inside the resonator cavity of the laser the sensitivity of the absorption measurement... [Pg.2460]

It may also be noted that, subject to the conditions of infinitesimal particle size, the above differential equations will still hold true even if collimated radiation at an angle of 60° to the surface normal is used instead of diffuse irradiation since for an incident angle of 60° ... [Pg.31]


See other pages where Collimated radiation is mentioned: [Pg.593]    [Pg.356]    [Pg.356]    [Pg.22]    [Pg.222]    [Pg.22]    [Pg.168]    [Pg.355]    [Pg.247]    [Pg.116]    [Pg.449]    [Pg.176]    [Pg.466]    [Pg.283]    [Pg.214]    [Pg.66]    [Pg.67]    [Pg.191]    [Pg.605]    [Pg.606]    [Pg.97]    [Pg.525]    [Pg.36]    [Pg.114]    [Pg.491]    [Pg.67]    [Pg.138]    [Pg.518]    [Pg.245]    [Pg.162]   
See also in sourсe #XX -- [ Pg.138 ]




SEARCH



Collimated

© 2024 chempedia.info