Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Chromatography reports types

GC using chiral columns coated with derivatized cyclodextrin is the analytical technique most frequently employed for the determination of the enantiomeric ratio of volatile compounds. Food products, as well as flavours and fragrances, are usually very complex matrices, so direct GC analysis of the enantiomeric ratio of certain components is usually difficult. Often, the components of interest are present in trace amounts and problems of peak overlap may occur. The literature reports many examples of the use of multidimensional gas chromatography with a combination of a non-chiral pre-column and a chiral analytical column for this type of analysis. [Pg.218]

Purification of aequorin. The purification method of aequorin reported by Shimomura et al. (1962) was essentially the repetition of column chromatography on DEAE-cellulose, the only usable, efficient chromatographic adsorbent available at the time. Since then, various different types of chromatographic media have been developed, and the purification method has been steadily improved. [Pg.98]

The most common approaches to sulfonylurea determinations involve high-performance liquid chromatography (HPLC). The earliest reported methods utilized normal-phase liquid chromatography (LC) with photoconductivity detection this type of detector demonstrated undesirably long equilibration times and is no longer... [Pg.400]

Validations fall into two types prospective and retrospective. In prospective validation (see flow chart in Figure 2) the validation is done in a sequential manner, involving installation qualification and operational qualification (IQ/OQ) of equipment (e.g., chromatography instrumentation or column hardware). Appropriate calibrations accompany the IQ/OQ. Process qualification, or PQ, involves formal review and approval of a PQ protocol, execution of this protocol, and issuance of a formal PQ report which includes data analysis and recommendations (i.e., approval/certification of the process). If the process is not approved, the report may recommend a redesign or redoing of the validation protocol and, in some cases, a return of the process to process development for further optimization. [Pg.118]

Bravo, 1984). Hybrids of these systems, where chromatography and electrophoresis are used in each spatial dimension, were reported nearly 40 years ago (Efron, 1959). Belenkii and coworkers reported on the analysis of block copolymers by TLC (Gankina et al., 1991 Litvinova et al., 1991). Two-block copolymers of styrene and f-butyl methacrylate were separated first with regard to chemical composition by TLC at critical conditions, followed by a SEC-type separation to determine the molar masses of the components. [Pg.389]

The symmetrical diphenyl-substituted porphyrazines M[pzPh8], where Ph = phenyl, were the first type of hydrocarbon-substituted pz to be reported. These macrocycles were prepared in 1937 by Linstead and co-worker (19) via melts of various metal salts with diphenylmaleonitrile and purified by chromatography. No... [Pg.486]


See other pages where Chromatography reports types is mentioned: [Pg.75]    [Pg.125]    [Pg.261]    [Pg.66]    [Pg.47]    [Pg.62]    [Pg.63]    [Pg.341]    [Pg.75]    [Pg.95]    [Pg.121]    [Pg.133]    [Pg.34]    [Pg.685]    [Pg.281]    [Pg.206]    [Pg.168]    [Pg.67]    [Pg.310]    [Pg.100]    [Pg.292]    [Pg.287]    [Pg.685]    [Pg.5]    [Pg.77]    [Pg.36]    [Pg.235]    [Pg.820]    [Pg.229]    [Pg.247]    [Pg.141]    [Pg.201]    [Pg.220]    [Pg.599]    [Pg.145]    [Pg.705]    [Pg.387]    [Pg.336]    [Pg.284]    [Pg.234]    [Pg.165]    [Pg.436]    [Pg.205]    [Pg.34]   
See also in sourсe #XX -- [ Pg.125 , Pg.126 , Pg.127 ]




SEARCH



© 2024 chempedia.info