Channel array

Unlike the array collector, with a microchannel plate all ions of only one m/z value are detected simultaneously, and instrument resolution does not depend on the number of elements in the micro-channel array or on the separation of one element from another. For a microchannel plate, resolution of m/z values in an ion beam depends on their being separated in time by the analyzer so that their times of arrival at the plate differ. [Pg.410]

Fig. 2.70 Micro-channel array formed by silicon DRIE. Reprinted from Kandlikar and Grande (2002) with permis-... Fig. 2.70 Micro-channel array formed by silicon DRIE. Reprinted from Kandlikar and Grande (2002) with permis-...
SuGiURA, S., Nakajima, M., Seki, M., Monodispersed droplet formation caused by intetfacial tension from microfabricated channel array, in Matlosz, M., Eheeeld,... [Pg.123]

This simple reactor concept is based on a microstructured silicon chip (Figure 3.18) covered by a Pyrex-glass plate by anodic bonding [73, 74]. The silicon microstructure comprises, in addition to inlet and outlet structures, a multi-channel array. Only the Pyrex-glass plate acts as cover and inlet and outlet streams interface the silicon chip from the rear. [Pg.278]

Figure 4.11 2x2 micro channel-array chip reactor realized in glass [23. ... [Pg.390]

Interdigital micro mixers comprise feed channel arrays which lead to an alternating arrangement of feed streams generating multi-lamellae flows [39 2]. If processes have to be carried out with extended residence times (> 1 s) and/or at a temperature level different from the mixing step, tubes have to be attached to the interdigital micro mixers. Their internals comprise millimeter dimensions or below, if necessary. [Pg.399]

This micro reactor consists of five ceramic layers [70, 71]. The top layer contains two bores for flnid feed and withdrawal. The second layer contains the flow distribution structures. The third comprises a micro channel array. The fourth carries the above-mentioned electrode structures. The last layer is an unstructured plate (Figure 4.34). [Pg.414]

A locally resolved detection of radioactive samples after chromatographic separation can be performed by imaging techniques which work either indirectly with Eu3+- or P-doped sensor plates and laser activated emission or directly by a micro channel array detector which works like an open Geiger-Muller counter. [Pg.77]

S. Sugiura, M. Nakajima, S. Iwamoto, and M. Seki Interfacial Tension Driven Monodispersed Droplet Formation from Microfabricated Channel Array. Langmuir 17, 5562 (2001). [Pg.43]

Figure 36 shows images recorded from a four-channel array in which the preferential flow of the liquid in the corners of the channels was investigated as a function of the nature of the distributor and the liquid velocity. Non-uniformities of the liquid distribution over the four corners of the square channels were apparent in addition to any maldistribution over the cross-section of the monolith. [Pg.55]

ESI-Mass spectra were obtained using JEOL HX/HX110A mass spectrometer equipped with ESI source (Analytica of Branford, Branford, Cl) and channel array detector, calibrated in the FAB mode with alkali metal iodides. Sample solutions were diluted 2000- fold with 50% aqueous methanol (v/v) containing 0.1% acetic acid. [Pg.121]

Such multi-platelet stacks were realized with tilted, straight (V-type) and curved (P-type) multi-channel arrays (see Figure 1.81) [41]. The V-type device has slanted outlets so that neighboring jets may collide the P-type has parallel streams. [Pg.108]

Fig. 14 b. Electron micrograph showing the inlet and side bed channel arrays (reprinted with permission from [81]. Copyright 1994 American Chemical Society)... [Pg.77]

A 2D channel array has been fabricated on a quartz chip intended for 2D CE application, as shown in Figure 6.41. The first dimension consists of a single... [Pg.179]

Another important family of ligand gated ion channels is the receptors for the excitatory amino acid neurohansmitters such as glutamate and aspartate (Figure 10.8). These act as neurotransmitters at the vast majority of excitatory synapses in the brain. These receptors are also multisubunit ion channel arrays, in this case consisting of tehamers of related subunits (Wollmuth and Sobolevsky, 2004). The proteins that make up these subunits are all related in structure but are quite different from those that make up the nicotinic and GABA-A receptor family. [Pg.117]

The geometry of the internally finned monolith can be varied in a wide range. A number of possible geometric configurations are described in a patent on the application of the internally finned monolith as an element in a gas-liquid-solid reactor [9]. Geometric variables include channel size and shape, number of fins, fin height and thickness, channel array, pitch, and wail thickness. [Pg.313]

The synthesis of mesoporous materials has been investigated at various conditions. The nature, the pore size, the wall thickness, the channel array and the morphology of the obtained materials have been characterized by powder X-ray diffraction, BET and Scanning Electron Microscopy. The present work shows that in the studied conditions, the pore diameter remains relatively constant while the thickness of the walls increases significantly with increasing time and temperature, signifying that the condensation of the source of silicium around the micelles is enhanced From the characterization results, a synthesis mechanism is postulated. [Pg.269]

As mentioned previously, one of the main differences between one- and two-channel arrays is that the latter are based on the competitive hybridization of two RNA samples with the probes on the array. In practice, this implies that two-color arrays are intended to quantify how much each gene is expressed in one sample relatively to the other. [Pg.16]

Differentiating microbes from non-biological particles in water was a challenge for bacteria ranging in size from 500 nanometers to two microns, depending on the size and water particle background, until the two-dimensional, mnlti-channel array was introduced into the system. This system, BioSentry vl. 75, is scheduled for release in August, 2006. [Pg.19]


See other pages where Channel array is mentioned: [Pg.2]    [Pg.10]    [Pg.259]    [Pg.511]    [Pg.590]    [Pg.496]    [Pg.601]    [Pg.79]    [Pg.95]    [Pg.103]    [Pg.431]    [Pg.77]    [Pg.358]    [Pg.152]    [Pg.452]    [Pg.454]    [Pg.482]    [Pg.8]    [Pg.1849]    [Pg.271]    [Pg.273]    [Pg.71]    [Pg.1032]    [Pg.1035]    [Pg.244]   