Changing fractions

The number of it and o electrons is not monitored during the dynamics, but the number of unpaired spins is. Most often the number of unpaired spins changes fractionally and thus slowly, but once a jump of six was seen for a few tens of steps with no noticeable accompanying error in the total energy. [Pg.122]

To change fractions the following must be done in sequence Remove the source of heat, release the vacuum, change the receiver, restore the vacuum to the former pressure, resume heating. [Pg.85]

Many organic compounds are thermally unstable. The distillation of compounds boiling above about 120 to 150° at atmospheric pressure is therefore usually effected under reduced pressure in order to lower the boiling point. This introduces several problems, such as changing fractions and maintaining a constant pressure. [Pg.26]

The pump is attached to a potassium hydroxide trap and a dry-ice trap in order to protect it. Stopcock Si is normally set so that the pump is connected to the manostat, but not to the arm having the manometer. The ballast volume is used to keep the pump side of the manostat below the system pressure even when the pump is disconnected for a short time, as in changing fractions. The manostat... [Pg.32]

When one wishes to change fractions using the fraction cutter described above, the stopcock B on the cutter is turned so that the manostat is still connected to the system but is not connected to the receiver. Stopcock A is turned 180° to connect the auxiliary position of the fraction cutter with that of the pump. Stopcock Sj on the pump table is turned to connect arms x and y and disconnect 2. Air is bled into the system through S3, and the flask is changed. The new... [Pg.32]

If this system for changing fractions is used, the distillation may be continued without interruption while changing fractions. This is a decided convenience in ordinary distillation under reduced pressure and is essential when conducting fractional distillations under these conditions. [Pg.33]

The gas is taken from the column into an evacuated bulb of known volume, to which is attached a mercury manometer. The rate of flow into the bulb is determined by the setting of the stopcock between the column and the gas-collecting system. The amount of gas which has been collected is determined from the volume of the bulb and the observed pressure. In order to change fractions, the stopcock to the bulb which was in use is closed and that to the next is opened. In order to minimize mixing of fractions in the gas-collecting system, the connections should be as short as possible and should be made of small-Jiameter tubing. [Pg.144]

Milne PA, Foley RJ, Brown PJ, Narayan G. The Changing Fractions of Type 1A Supernova NUV-Optical Subclasses with Redshift. Astrophys. Jour. 2015 803 20 15 pages. DOI 10.1088/0004-637X/803/120... [Pg.252]

In TLC separated sample bands can be recovered directly from the plate without difficulty (2). Automatic fraction collectors can be quite useful in column chromatography. The latter are available in a variety of forms and degrees of complexity. For a general review see Refs. (/) and (31). For a discussion of the limitations of different fraction collectors, see Refs. (32-34). Ideally, each fraction collected should contain a single sample band this can be achieved by devices which change fractions when the detector senses a minimum between two peaks [v-h of Fig. 13-1 sec discussion of Ref. (/)]. [Pg.179]

Low-pressure chromatography typically requires hours, so a fraction collector is a necessity. It is best to configure the system so that a tick mark is made on the strip chart recorder during fraction changes. Fractions can be analyzed by analytical HPLC to determine which ones contain the peptide of interest. Fractions are then pooled and lyophilized. In cases in which preparative HPLC is the next step, the pooled fractions can be pumped directly onto the column. [Pg.739]

In spite of these advantages the SMDE has a limited application in industrial process monitoring due to the troubles with, e.g., the drop recalibration. Another important limitation of the SMDE in comparison with the DME is that the data on the continuously changing fraction of the drop are not available. It must be recalled that the shape of the currenttime profile allows to distinguish some kinetic currents and to demonstrate also the presence of the adsorption phenomena. For this reason the application of the continuously growing drop electrode is justified in some experimental studies. Such measurements, in which both... [Pg.149]

Description Mass Change ([>) Fractional Mass Change (mp.) Formula Change... [Pg.423]

Y, = Mole fraction of light key component in overhead Y(, = Mole fraction of heavy key component in overhead X = Mole fraction of light key component in bottoms Xh = Mole fraction of heavy key component in bottoms H = A number proportional to reboiler duty AH = Percent change in reboiler duty due to changing fractionation... [Pg.378]

In practice we do not have separation as a MV we instead adjust it by changing fractionation. The terms separation and fractionation are often used interchangeably. This is not strictly correct. Separation is a measure of product composition, while fractionation is a measure of energy used. They are certainly related in that increasing fractionation will increase separation but, as we will see later, separation is influenced by many other parameters. [Pg.280]

Figure 12.23 shows the effect of that varying the reboiler duty has on the composition of both products. In this case cut has been kept constant which, depending on how the basic controls have been configured, may not be the real situation. It nevertheless shows that, as we change fractionation, both product compositions change. [Pg.280]


See other pages where Changing fractions is mentioned: [Pg.195]    [Pg.173]    [Pg.391]    [Pg.62]    [Pg.391]    [Pg.385]    [Pg.76]    [Pg.85]    [Pg.26]    [Pg.32]    [Pg.64]    [Pg.114]    [Pg.79]    [Pg.253]    [Pg.7]    [Pg.87]    [Pg.334]    [Pg.163]   
See also in sourсe #XX -- [ Pg.85 ]