Centrifugation fixed angle rotors

Free subcellular particles or virus from Percoll by centrifuging the respective fraction of cell fractionation in a fixed-angle rotor at 100 000 X g for 90 min. Percoll forms a solid pellet whidi contains practically no material of interest. [Pg.179]

Operation of a fixed angle rotor A Loading of sample B Sample at start of centrifugation C Bands form as molecules sediment D Rotor at rest showing separation of two components... [Pg.197]

Figure 10.5 Pore water extraction by (A) drainage centrifugation using a swing-out rotor and (B) immiscible liquid displacement using a fixed-angle rotor (after Kinniburgh and Miles, 1983). Figure 10.5 Pore water extraction by (A) drainage centrifugation using a swing-out rotor and (B) immiscible liquid displacement using a fixed-angle rotor (after Kinniburgh and Miles, 1983).
Thermostatized centrifuge with fixes angle rotor (angle of inclination 33°) (e.g. Hettich Rotixa RP 001260 Tuttlingen Germany)... [Pg.477]

Figure 4-36. Fixed angle rotor. On the left is illustrated a conventional centrifuge tube, in which liquid is pressed against the lid during centrifugation. The right depicts a tube with an offset neck to avoid this problem. Figure 4-36. Fixed angle rotor. On the left is illustrated a conventional centrifuge tube, in which liquid is pressed against the lid during centrifugation. The right depicts a tube with an offset neck to avoid this problem.
Figure 13.2. Centrifugal forces in different rotor types. The angle is measured with respect the rotation axis, these means than a fixed-angle rotor with an angle of 14° is related to a vertical rotor, and therefore its sedimentation pathlength is shorter than in a 40° rotor. Figure 13.2. Centrifugal forces in different rotor types. The angle is measured with respect the rotation axis, these means than a fixed-angle rotor with an angle of 14° is related to a vertical rotor, and therefore its sedimentation pathlength is shorter than in a 40° rotor.
Ultrafiltration. The second method is an ultrafiltration procedure for FT4 determination in serum that is significantly less time-consmning than dialysis. " In this method, the serum specimen is adjusted to pH 7.4, incubated for 20 minutes at 37 °C (to achieve equilibrium of the binding at this temperature), and then appfied to an ultrafiltration device for centrifugation for 30 minutes at 37 °C and 2000 Xg (using a fixed-angle rotor). Subsequently the ultrafiltrate is analyzed for T4. Variable protein leakage in ultrafiltration devices continues to hamper commercialization of this method. [Pg.2074]

Centrifugation With the concentration devices from the Amicon company, the solution to be concentrated is centrifuged in a fixed-angle rotor over a filter (max. 5,000 g). The concentrate collects above the filter and can be transferred into an Eppendorf tube in a second centrifugation step. The different systems (Microcon, Centricon, Centriprep) concentrate 0.5 to 15 ml of source solution into 5 to 500 pi. Depending on the filter, the process takes between 10 minutes and 3 h. The company offers filters with MG limits from 3 to 100 kd. [Pg.14]


See other pages where Centrifugation fixed angle rotors is mentioned: [Pg.200]    [Pg.200]    [Pg.211]    [Pg.161]    [Pg.307]    [Pg.161]    [Pg.162]    [Pg.165]    [Pg.177]    [Pg.195]    [Pg.195]    [Pg.199]    [Pg.201]    [Pg.195]    [Pg.195]    [Pg.199]    [Pg.201]    [Pg.228]    [Pg.173]    [Pg.174]    [Pg.176]    [Pg.397]    [Pg.403]    [Pg.478]    [Pg.130]    [Pg.131]    [Pg.66]    [Pg.140]    [Pg.141]    [Pg.142]    [Pg.149]    [Pg.75]    [Pg.17]    [Pg.308]    [Pg.250]    [Pg.264]    [Pg.265]    [Pg.394]    [Pg.399]    [Pg.203]    [Pg.203]    [Pg.209]   