Catalase-Biomimetic Sensors

Figure 8.2 shows an electrochemical system - a model of a catalase-biomimetic sensor, consisting of the reference electrode (Ag/AlCl/Cl ) and biomimetic electrode. In this system, the electrochemical potential changed as a result of mimetic electrode interaction with... [Pg.293]

The change of electrode potential (E) of the catalase reaction with time was measured by a voltmeter. pH and E values for aqueous hydrogen peroxide were determined simultaneously for possible correlations between pH metric and potentiometric results of enzymatic activity of catalase-biomimetic sensors. The electrochemical unit was also equipped with a magnetic mixer. [Pg.294]

Physicochemical fundamentals of construction and action of catalase- and peroxidase-biomimetic sensors are studied. [Pg.289]

For the purpose of determining low hydrogen peroxide concentrations, the authors have designed the most cost-effective and simple to use potentiometric-biomimetic sensors based on immobilized catalase mimics. These sensors possess high hydrodynamic properties and the fastest speed of response. Figure 8.3 shows experimental data on catalase activity of biomimetic electrode in 0.03% aqueous H202. For the sake of comparison, catalase activities of aluminum electrode and aluminum electrode with applied adhesive are also shown. [Pg.294]

Biomimetic sensors, prepared from catalase adsorbed on diasorb and A1203, treated with trypsine and adhered to an aluminum electrode surface using 7.5% polyacrylamide gel of... [Pg.299]

Biomimetic sensors, prepared by catalase adsorption on diasorb and agarose (treated with trypsine) and adhered to an aluminum electrode surface by Pattex adhesive, displayed an abrupt decrease of the electrode potential. Sensors prepared by catalase adsorption on A1203 (without trypsine treatment) and adhesion to the aluminum electrode with Pattex adhesive displayed a high oscillation of the electrode potential, which induces extreme instability of the operation. Hence, it should be noted that sensor operation was always better in the case of enzyme treatment with trypsine. [Pg.301]

The investigations of catalase-mimetic sensors allow continuation of studies in the field of biomimetic sensors of peroxidase type. [Pg.302]


See other pages where Catalase-Biomimetic Sensors is mentioned: [Pg.292]    [Pg.293]    [Pg.295]    [Pg.297]    [Pg.299]    [Pg.301]    [Pg.292]    [Pg.293]    [Pg.295]    [Pg.297]    [Pg.299]    [Pg.301]    [Pg.294]    [Pg.301]   