Ramsey, C. B. (2005), OxCal Radiocarbon Calibration Software, http //www.rlaha. ox.ac.uk/orau/oxcal.htm. [Pg.607]

Easy calibration of direct control lead screw piston drive with flow calibration software... [Pg.374]

The use of the materials and the best chemical forms to be chosen have been discussed briefly in the section on validation. Details taken from Moody et al. and Wells are given in Tables 2.5a and b. The chemometric tools to be applied for the calibration of the signal and the calculation of the confidence interval of the calibration curve have been extensively detailed in several manuals and in particular the second book of Massart et al. [7] or in the text book of the FECS [48]. Modern automated spectrometers usually include adapted and properly validated calibration software. [Pg.62]

To calibrate at 0°C/min, construct a graph of the onset of melting temperature against heating rate and extrapolate back to the onset temperature for 0°C/min. This value is then entered into the temperature calibration software of the DSC. [Pg.28]

Calibration Technician Accurate and repeatable measurements are essential to chemists working in research and industry. An instrument calibration technician adjusts, troubleshoots, maintains, and repairs the instruments used in laboratories and manufacturing plants. Their jobs require an understanding of the instrument s electronics and the use of computers and calibration software. For more information on chemistry careers, visit glencoe.com. [Pg.56]

In the X-ray analytical laboratory the quantitative method of analysis employed wiU be typically determined by a number of circumstances of which probably the four most common are the complexity of the analytical problem the time allowable the data processing and calibration software present and the number of standards... [Pg.409]

When calibrating a DSC or any other thermal analysis analyzer, the previous calibration values that are applied in the software should be erased. This is easily done via the software by restoring defaults. Defaulted values are calibration settings that the factory sets as a common value for all DSCs produced. If you don t restore defaults, you will be calibrating incorrectly by installing your calibration factors on top of previous calibration factors. To understand exactly how your calibration software operates, refer to the instrument documentation provided by the manufacturer. [Pg.105]

Now enter the calculated and expected values for distilled water and indium into the calibration software per the manufacturer s instructions and apply them to the DSC. The analyzer is now properly calibrated and ready to run sample specimens. [Pg.108]

LABSOCS LABoratory SOurceless Calibration Software -commercial computer prt ram for estimating activities in a labtnatory environment without source-based efficiency calibration. [Pg.375]

The GHTF has proposed a harmonized definition for medical devices, which means any instrument, apparatus, implanent, machine, appliance, implant, in vitro reagent or calibrator, software, material, or other similar or related article intended by the manufacturer to be used, alone or in combination, for human beings for one or more of the specific purposes of ... [Pg.205]

Software for both controlling the hyphenated combination of techniques and efficient processing of the data is of utmost importance to the breakthrough and general use of a hyphenated technique. In this respect, the development of automatic tuning and calibration software for GC-MS and more recently LC-MS, of computer spectral library searching after electron ionization, and of efficient quantitation software packages after both GC-MS and LC-MS can be considered as important steps in the development of hyphenated techniques. Control of the complete (often multivendor) instrumentation. [Pg.848]

Calibrate the GMF robot using the generic forward kinematic calibration software developed at Texas A M University. [Pg.457]

The test environment that has been set up consists of a Bosch Scara arm, where the camera and light source are placed at the end effector. The Bosch controller is connected to a SUN workstation, on which the robot program is generated. This SUN workstation is also used by the HLI, and the calibration software. The sensor processing hard- and soft-ware is located in a VME crate, allowing easy exchange of components without rebooting the entire system. [Pg.464]


See other pages where Calibration software is mentioned: [Pg.288]    [Pg.96]    [Pg.203]    [Pg.23]    [Pg.107]    [Pg.159]    [Pg.510]    [Pg.72]    [Pg.516]    [Pg.203]    [Pg.47]    [Pg.261]    [Pg.923]    [Pg.162]    [Pg.361]    [Pg.141]    [Pg.110]    [Pg.325]    [Pg.327]    [Pg.385]    [Pg.386]    [Pg.51]    [Pg.464]   