Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Buffer defined

Three nonaqueous buffers defined by the National Bureau of Standards, which contain 50% (by weight) methanol, result in higher pH values than aqueous solutions of the same solutes and molalities. These buffers are defined in Table 4.3. [Pg.86]

Figure B2.5.1 schematically illustrates a typical flow-tube set-up. In gas-phase studies, it serves mainly two purposes. On the one hand it allows highly reactive shortlived reactant species, such as radicals or atoms, to be prepared at well-defined concentrations in an inert buffer gas. On the other hand, the flow replaces the time dependence, t, of a reaction by the dependence on the distance v from the point where the reactants are mixed by the simple transfomiation with the flow velocity vy... Figure B2.5.1 schematically illustrates a typical flow-tube set-up. In gas-phase studies, it serves mainly two purposes. On the one hand it allows highly reactive shortlived reactant species, such as radicals or atoms, to be prepared at well-defined concentrations in an inert buffer gas. On the other hand, the flow replaces the time dependence, t, of a reaction by the dependence on the distance v from the point where the reactants are mixed by the simple transfomiation with the flow velocity vy...
Values based on the conventional activity pH scale as defined by the National Bureau of Standards (U.S.) and pertain to a temperature of 25°C [Ref Bower and Bates, J. Research Natl. Bur. Standards U.S., 55 197 (1955) and Bates and Bower, Anal. Chem., 28 1322 (1956)]. Buffer value is denoted by column headed /3. [Pg.934]

Calibrating the electrode presents a third complication since a standard with an accurately known activity for H+ needs to be used. Unfortunately, it is not possible to calculate rigorously the activity of a single ion. For this reason pH electrodes are calibrated using a standard buffer whose composition is chosen such that the defined pH is as close as possible to that given by equation 11.18. Table 11.6 gives pH values for several primary standard buffer solutions accepted by the National Institute of Standards and Technology. [Pg.492]

Mutagenic PGR. More recently, methods have been developed to use the PGR reaction to randomly mutagenize a defined sequence (25). The Taq polymerase used in PGR misincorporates nucleotides in a random fashion if manganese dichloride [7773-01 -5] MnGl2, is included in the reaction buffer during PGR. The Hbrary of mutagenized PGR products can be screened for the desired phenotype. [Pg.237]

Traditional chemical kinetics uses notation that is most satisfactory in two cases all components are gases with or without an inert buffer gas, or all components are solutes in a Hquid solvent. In these cases, molar concentrations represented by brackets, are defined, which are either constant throughout the system or at least locally meaningful. The reaction quotient Z is defined as... [Pg.507]

Tripotassium dicitratobismuthate [57644-54-9] (bismuth subcitrate), De-Nol is a buffered aqueous suspension of a poorly defined, water-insoluble bismuth compound. It is said to very effective for the treatment of gastric and duodenal ulcers (180,184). There have not yet been any reports of bismuth encephalopathy following the use of this dmg. [Pg.135]

I0-38Z ) is solved to give the temperature distribution from which the heat-transfer coefficient may be determined. The major difficulties in solving Eq. (5-38Z ) are in accurately defining the thickness of the various flow layers (laminar sublayer and buffer layer) and in obtaining a suitable relationship for prediction of the eddy diffusivities. For assistance in predicting eddy diffusivities, see Reichardt (NACA Tech. Memo 1408, 1957) and Strunk and Chao [Am. ln.st. Chem. Eng. J., 10, 269(1964)]. [Pg.560]

It may happen that AH is not available for the buffer substance used in the kinetic studies moreover the thermodynamic quantity A//° is not precisely the correct quantity to use in Eq. (6-37) because it does not apply to the experimental solvent composition. Then the experimentalist can determine AH. The most direct method is to measure AH calorimetrically however, few laboratories Eire equipped for this measurement. An alternative approach is to measure K, under the kinetic conditions of temperature and solvent this can be done potentiometrically or by potentiometry combined with spectrophotometry. Then, from the slope of the plot of log K a against l/T, AH is calculated. Although this value is not thermodynamically defined (since it is based on the assumption that AH is temperature independent), it will be valid for the present purpose over the temperature range studied. [Pg.258]

Tire fulvalenium salts 35 and 38 react reversibly in aqueous buffer solutions to yield the corresponding triarylcyclopropenols, as evidenced by the well-defined isosbestic points in their UV spectra. Tire pK values derived from spectra are compatible with extensive delocalization of charge in the heterocyclic ring (68TL5541). [Pg.151]

In order to obtain good yields from a Weiss reaction sequence, the H+-concentration has to be adjusted properly in the reaction mixture. The reaction is usually carried out in a buffered, weakly acidic or weakly basic solution. By the Weiss reaction simple starting materials are converted into a complex product of defined stereochemistry. There is no simpler procedure for the synthesis of the l,5-c -disubstituted bicyclo[3.3.0]octane skeleton it has for example found application in the synthesis of polyquinanes. ... [Pg.289]

Fig. 3-3. Comparison of the values of enantiomeric resolution of different DNP-D,L-amino acids at different deconvolution stages of a cyclic hexapeptide sublibrary. Resolution values in a cyclo(Arg-Lys-X-X-X-P-Ala) sublibrary, in the first line, are compared to those obtained in sublibraries with a progressively increasing number of defined positions. All the sublibraries were 30 mM in the running buffer while the completely defined cyclo(Arg-Lys-Tyr-P-Tyr-P-Ala) peptide is used at 10 mM concentration. Conditions cyclopeptide sublibrary in 20 mM sodium phosphate buffer, pH 7.0 capillary, 50 pm i.d., 65 cm total length, 57 cm to the window V = -20 kV, I = 40 electrokinetic injection, -10 kV, 3 s detection at 340 nm. (Reprinted with permission from ref. [75]. Copyright 1998, American Chemical Society.)... Fig. 3-3. Comparison of the values of enantiomeric resolution of different DNP-D,L-amino acids at different deconvolution stages of a cyclic hexapeptide sublibrary. Resolution values in a cyclo(Arg-Lys-X-X-X-P-Ala) sublibrary, in the first line, are compared to those obtained in sublibraries with a progressively increasing number of defined positions. All the sublibraries were 30 mM in the running buffer while the completely defined cyclo(Arg-Lys-Tyr-P-Tyr-P-Ala) peptide is used at 10 mM concentration. Conditions cyclopeptide sublibrary in 20 mM sodium phosphate buffer, pH 7.0 capillary, 50 pm i.d., 65 cm total length, 57 cm to the window V = -20 kV, I = 40 electrokinetic injection, -10 kV, 3 s detection at 340 nm. (Reprinted with permission from ref. [75]. Copyright 1998, American Chemical Society.)...
In the galvanic detector, the electrochemical detector consists of a noble metal like silver (Ag) or platinum (Pt), and a base metal such as lead (Pb) or tin (Sn), which acts as anode. The well-defined galvanic detector is immersed in the electrolyte solution. Various electrolyte solutions can be used, but commonly they may be a buffered lead acetate, sodium acetate and acetic acid mixture. The chemical reaction in the cathode with electrons generated in the anode may generate a measurable electrical voltage, which is a detectable signal for measurements of DO. The lead is the anode in the electrolyte solution, which is oxidised. Therefore the probe life is dependent on the surface area of the anode. The series of chemical reactions occurring in the cathode and anode is ... [Pg.75]

Danckwerts et al. (D6, R4, R5) recently used the absorption of COz in carbonate-bicarbonate buffer solutions containing arsenate as a catalyst in the study of absorption in packed column. The C02 undergoes a pseudo first-order reaction and the reaction rate constant is well defined. Consequently this reaction could prove to be a useful method for determining mass-transfer rates and evaluating the reliability of analytical approaches proposed for the prediction of mass transfer with simultaneous chemical reaction in gas-liquid dispersions. [Pg.302]

In the Taylor-Prandtl modification of the theory of heat transfer to a turbulent fluid, it was assumed that the heat passed directly from the turbulent fluid to the laminar sublayer and the existence of the buffer layer was neglected. It was therefore possible to apply the simple theory for the boundary layer in order to calculate the heat transfer. In most cases, the results so obtained are sufficiently accurate, but errors become significant when the relations are used to calculate heat transfer to liquids of high viscosities. A more accurate expression can be obtained if the temperature difference across the buffer layer is taken into account. The exact conditions in the buffer layer are difficult to define and any mathematical treatment of the problem involves a number of assumptions. However, the conditions close to the surface over which fluid is flowing can be calculated approximately using the universal velocity profile,(10)... [Pg.727]

Standard curves performed under our defined radioimmunoassay conditions ([ H]PbTx-3 = 1 nM, antiserum dilution = 1 2000, assay volume = 1 ml) demonstrated the ability of this antiserum to bind equally to PbTx-2 and PbTx-3, suggesting specificity for the cyclic polyether backbone region of the molecule (Figure 8). The linear portion of the curve indicated a lower detection limit of 0.2-0.5 ng in saline buffer under these conditions. Evaluation of this assay for use with biological fluids and tissue extracts is underway. [Pg.187]

Whole cell OPH activity was measured by following the increase in absorbancy of p-nitrophenol from the hydrolysis of substrate (0.1 mM Paraoxon) at 400 nm (sm = 17,000 M cm ). Samples of culture (1 ml) were centrifuged at 10,000 g and 4 C for 5 min. The cells were washed, resuspended with distilled water, and 100 pi was added to an assay mixture containing 400 pi 250 mM CHES [2-(N-cyclohexylamino)ethane-sulfonic acid] buffer, pH 9.0, 100 pi 1 mM Paraoxon, and 400 pi distilled water. One unit of OPH activity was defined as pmoles Paraoxon hydrolyzed per min. Each value and error bar represents the mean of two independent experiments and its standard deviation. [Pg.174]


See other pages where Buffer defined is mentioned: [Pg.616]    [Pg.102]    [Pg.531]    [Pg.129]    [Pg.616]    [Pg.102]    [Pg.531]    [Pg.129]    [Pg.327]    [Pg.68]    [Pg.52]    [Pg.385]    [Pg.465]    [Pg.265]    [Pg.256]    [Pg.40]    [Pg.157]    [Pg.50]    [Pg.331]    [Pg.147]    [Pg.694]    [Pg.586]    [Pg.195]    [Pg.15]    [Pg.346]    [Pg.289]    [Pg.289]    [Pg.206]    [Pg.207]    [Pg.94]    [Pg.263]    [Pg.101]    [Pg.46]    [Pg.462]    [Pg.535]    [Pg.540]    [Pg.586]   
See also in sourсe #XX -- [ Pg.839 ]




SEARCH



© 2024 chempedia.info