Breakthrough sampling

However unlike H which is the most abundant of the hydrogen isotopes (99 985%) only 1 1% of the carbon atoms m a sample are Moreover the intensity of the signal produced by nuclei is far weaker than the signal produced by the same number of H nuclei In order for NMR to be a useful technique in structure deter mination a vast increase in the signal to noise ratio is required Pulsed FT NMR pro vides for this and its development was the critical breakthrough that led to NMR becoming the routine tool that it is today... [Pg.547]

Along a different line of research on shock compression of solids, namely, recovery experiments, great progress was also being made. Shock-induced recovery-type chemical reactions in encapsulated samples were first reported by Riabinin in 1956. Shock-induced metallographic transformation and the observation of twin bands in iron were first reported by Smith in 1958. Another major breakthrough was the shock-induced synthesis of diamond in 1961 by DeCarli and Jamieson. [Pg.400]

Fig. 20. Typical C02/CH4 breakthrough plot for CFCMS monolith sample 21-11 (9% bum-off) at 25° C... Fig. 20. Typical C02/CH4 breakthrough plot for CFCMS monolith sample 21-11 (9% bum-off) at 25° C...
Fig. 22. CO2/CH4 breakthrough plots for CFCMS sample 21-lF (10% bum-off) showing the benefit of eleetrically enhanced desorption A. 1 volt, He purge 04 sipm B 1 volt, He purge 0.06 slpm, and C. 0 volt. He purge 0.06 slpm... Fig. 22. CO2/CH4 breakthrough plots for CFCMS sample 21-lF (10% bum-off) showing the benefit of eleetrically enhanced desorption A. 1 volt, He purge 04 sipm B 1 volt, He purge 0.06 slpm, and C. 0 volt. He purge 0.06 slpm...
A recovery of 5% of the total sample from the back-up section of charcoal in a sample tube was defined as the breakthrough point 50% of this value is shown as the recommended maximum tube loading, to allow for high humidity or the presence of other substances which reduce the normal tube capacity. [Pg.329]

These compounds migrate rapidly to the back-up section of the charcoal tube. A 400 mg tube should be used for sample collection with a second 100 mg tube in series behind the large tube to determine breakthrough. [Pg.329]

An alternative way of eliminating water in the RPLC eluent is to introduce an SPE trapping column after the LC column (88, 99). After a post-column addition of water (to prevent breakthrough of the less retained compounds), the fraction that elutes from the RPLC column is trapped on to a short-column which is usually packed with polymeric sorbent. This system can use mobile phases containing salts, buffers or ion-pair reagents which can not be introduced directly into the GC unit. This system has been successfully applied, for example, to the analysis of polycyclic aromatic hydrocarbons (PAHs) in water samples (99). [Pg.362]

Carbon monoxide is usually sampled as the second parameter in conjunction with carbon dioxide or oxygen. In theory, as the optimum is usually to have near-stoichiometric combustion without CO breakthrough it is the most reliable gas to sample. A problem is that although small quantities of CO usually indicate the need for additional air, they can also be caused by flame chilling and careful interpretation of results is needed. [Pg.276]

After aerosols are produced, various optical techniques can be used to determine their actual sizes and concentrations prior to introducing the aerosols to a sampling device. Various sizes of monodisperse aerosols can be introduced to the sampler, and its efficiency determined by measuring breakthrough using optical techniques and by... [Pg.922]

Various forms of carbon are used to sample those analytes whose breakthrough volume is too low on Tenax for sufficient preconcentration [8,395-399]. Charcoal, graphitized carbon blacks, and ceurbosieves with wface areas from 5 to 900 w /g are commercially availablJ Bhe high surface area sorbents are used... [Pg.930]


See other pages where Breakthrough sampling is mentioned: [Pg.185]    [Pg.121]    [Pg.263]    [Pg.4]    [Pg.185]    [Pg.121]    [Pg.263]    [Pg.4]    [Pg.1655]    [Pg.196]    [Pg.224]    [Pg.770]    [Pg.287]    [Pg.375]    [Pg.195]    [Pg.432]    [Pg.343]    [Pg.357]    [Pg.54]    [Pg.217]    [Pg.70]    [Pg.62]    [Pg.424]    [Pg.425]    [Pg.610]    [Pg.920]    [Pg.928]    [Pg.25]    [Pg.50]    [Pg.403]    [Pg.414]    [Pg.422]    [Pg.423]    [Pg.425]    [Pg.425]    [Pg.425]    [Pg.509]    [Pg.515]    [Pg.905]    [Pg.907]    [Pg.928]   
See also in sourсe #XX -- [ Pg.235 ]