Baseline causes

Techniques without a preceding separation step such as direct inlet probe MS [163] or H-NMR [69] allow one to estimate the sum concentration of toxaphene. In connection with GC/ECD, Walter and Ballschmiter used the so-called triangle method for this purpose. It estimates the area under the raised baseline caused by not resolved toxaphene peaks [174]. Although this method has to be... [Pg.267]

Other detection methods can be applied to CEC. Indirect spectrophotometric detection methods are commonly used for ultraviolet (UV)-transparent ionic analytes (such as inorganic ions) in CE, but indirect detection in CEC tends to suffer from unstable baselines, caused by adsorption of the indirect detection probe onto the CEC ion-exchange stationary phases (SP). Fluorimetric detection is a very sensitive and robust method, but is limited to a relatively small... [Pg.336]

Let us first examine the sign of this third coefficient. If it is negative, the viscosity decreases as time goes on. If it is positive, the viscosity may deviate upwards from the baseline = git fixed by the linear modulus. In other words, it shows an upturn at a certain time from the linear baseline. Such a stress growth beyond the linear baseline caused by a large deformation is called strain hardening. [Pg.313]

Probably the simplest way to separate proteins from small molecules is protein precipitation. It is needed for studying low-molecular-weight compounds (MW below 2-5 kDa), as the presence of macromolecules typically deteriorates analytical performance. In chromatography they lift the baseline, cause noise, and may even ruin chromatographic columns. In MS, they deteriorate ionization and may block the ion source. [Pg.42]

Figure 14 A parabolic baseline caused by misalignment of the interferometer. Figure 14 A parabolic baseline caused by misalignment of the interferometer.
About 1 g of surfactant is weighed out and dissolved in 4.0 mL of derivatizing reagent. After 5 min reaction, the solution is diluted to 10.0 mL with CH3CN, then filtered and diluted 1 10 with HPLC mobile phase. The resulting solution is analyzed promptly by HPLC. An Ultrasphere ODS (Beckman) column is used, 4.6 x 250 mm. The mobile phase consists of 60 40 acetonitrile/water, 0.1 M in HCl, pumped at 1 mL/min. Detection is by UV absorbance at 365 nm. The order of elution is formaldehyde, acetaldehyde, acetone, propionaldehyde. The samples should be analyzed within 2 hr of derivatization as there are side reactions which form formaldehyde from the reagents. Detection at 254 nm is not suitable because impurities contribute to the baseline, causing poor sensitivity. [Pg.77]

In attainment areas, new large faciUties must be designed to incorporate the best available control technology (BACT). Generally, BACT is more stringent than RACT and equal to or less stringent than LAER. In addition, there are also rules that specify how much deterioration in baseline air quaUty a new facihty can cause. In no situation can the faciUty cause a new violation in the NAAQS. [Pg.368]

In addition to these assessments of the causes and consequences of errors, the baseline assessment should also include an evaluation of the systems that are currently in place to control errors. This will include an evaluation of the current state of a representative set of the PIFs discussed in Chapter 3. Typical factors would include... [Pg.361]

The fact that we have peaks within a 2D space implies that where no peak is found represents a true detector baseline or electronic noise level. In a conventional petroleum sample, a complex unresolved mixture response causes an apparent detector baseline rise and fall throughout the GC trace. It is probably a fact that in this case the true electronic baseline is never obtained. We have instead a chemical baseline comprising small response to many overlapping components. This immediately suggests that we should have more confidence in peak area measurements in the GC X GC experiment. [Pg.92]

Returning to Figure 17, it is interesting to note how well CLS was able to estimate the low intensity peaks of Components 1 and 2. These peaks lie in an area of the spectrum where Component 4 does not cause interference. Thus, there was no distribution of excess absorbance from Component 4 to disrupt the estimate in that region of the spectrum. If we look closely, we will also notice that the absorbance due to the sloping baselines that we added to the simulated data has also been distributed among the estimated pure component spectra. It is particularly visible in Kl, Component 3 and K2 Component 2. [Pg.57]

The nurse obtains the vital signs at die time of the initial assessment to provide baseline data. The primary healtii care provider may order many laboratory and diagnostic tests, such as an electroencephalogram, computed tomographic scan, complete blood count, and hepatic and renal function tests to confirm the diagnosis and identify a possible cause of the seizure disorder, as well as to provide a baseline during therapy with anticonvulsants. [Pg.259]

In addition to the LGS brightness, a tilt isoplanatic angle

flux limitation only the fraction (p/e of the plume can be used to sense one component of the tilt. Lrom preliminary studies, the telescope diameter of the auxiliary telescopes should range around 25cm. This concept should provide us with a sky coverage > 50%, provided that the auxiliary telescopes can move across several hundred meters baselines. [Pg.263]

In other words, the change in baseline temperature is caused by a difference in the relative temperatures of sample and reference, which is related to their relative heat capacities. Thus, one needs to choose the reference material very carefully. If we subtract the equations in 7.1.30., we can get ... [Pg.373]

Baseline distortions. The relative motion of source and absorber causes periodic variations of the solid angle d and consequently of the incident count rate as a... [Pg.43]


See other pages where Baseline causes is mentioned: [Pg.36]    [Pg.394]    [Pg.305]    [Pg.119]    [Pg.332]    [Pg.85]    [Pg.843]    [Pg.173]    [Pg.281]    [Pg.352]    [Pg.1060]    [Pg.36]    [Pg.394]    [Pg.305]    [Pg.119]    [Pg.332]    [Pg.85]    [Pg.843]    [Pg.173]    [Pg.281]    [Pg.352]    [Pg.1060]    [Pg.507]    [Pg.314]    [Pg.99]    [Pg.570]    [Pg.200]    [Pg.22]    [Pg.240]    [Pg.182]    [Pg.204]    [Pg.689]    [Pg.285]    [Pg.19]    [Pg.45]    [Pg.380]    [Pg.46]    [Pg.186]    [Pg.463]    [Pg.389]    [Pg.1]    [Pg.209]    [Pg.186]    [Pg.234]    [Pg.282]    [Pg.286]    [Pg.290]    [Pg.318]   