In our case F, (t) K the obtained in TO sound area and stored in memory averaged signal (the reference signal), F (t) is the current signal. Reference signal parameters we shall mark with subscript r , current signal parameters with subscript e . [Pg.828]

Using the Regression Equation Once the regression equation is known, we can use it to determine the concentration of analyte in a sample. When using a normal calibration curve with external standards or an internal standards calibration curve, we measure an average signal for our sample, Yx, and use it to calculate the value of X... [Pg.122]

To calculate the standard deviation for the analyte s concentration, we must determine the values for y and E(x - x). The former is just the average signal for the standards used to construct the calibration curve. From the data in Table 5.1, we easily calculate that y is 30.385. Calculating E(x - x) looks formidable, but we can simplify the calculation by recognizing that this sum of squares term is simply the numerator in a standard deviation equation thus,... [Pg.123]

Once again, as you work through this example, remember that x represents the concentration of analyte in the standards (Cs), and y corresponds to the average signal (Smeas)- We begin by setting up a table to aid in the calculation of the weighting factor. ... [Pg.125]

If only time-averaged signals are observed, it. is necessary to resort to in-... [Pg.34]

Special attention has been given to the study of tautomeric equilibria in solutions of histidine 22 because the key functional role of such equilibria in proteins is recognized. In aqueous solutions the tautomers of histidine rapidly interconvert and only a single averaged signal is observed for each ring nitrogen (Scheme 10). [Pg.181]

In summary, the Fourier transform of a continuous signal digitized in 2A/ + 1 data points returns N real Fourier coefficients, N imaginary Fourier coefficients and the average signal, also called the DC term, i.e. in total 2N + 1 points. The relationship between the scales in both domains is shown in Fig. 40.9. [Pg.521]

In order to keep the average signal amplitude unaffected a scaling factor NORM is introduced, which is the sum off all convolutes, here 35. The smoothing procedure is now... [Pg.542]

Three times the standard deviation of the obtained average signal expressed as residue concentration Ten times the standard deviation of the obtained average signal expressed as residue concentration... [Pg.124]

Fig. 2.1.8 2D slices from a series of 3D data sets, acquired every 30 min (left). The average signal intensities from a region of interest from the center area of all 3D data sets were determined and are shown for the various times (right). The intensities are proportional... [Pg.66]

Three different lots of a standard 3.2-kb HCV RNA were serially diluted and quantified over a thousandfold range. The average signal per attomole of target varied by less than 20% among the three lots. [Pg.211]

S/N Signal-to-noise ratio of an average signal intensity y or a net intensity Jnet (elated to sy) (7.1)... [Pg.17]

Both ionic forms have the same set of characteristic bands in their IR spectra and thus cannot be identified in solution. The 3IP NMR spectrum contains only one averaged signal. The IR study revealed tautomeric transformations in solution. The characteristic absorption band of the P—H bond and carbonyl group appeared in solution spectra that is possible only on dissociation of the a-hydroxyalkyl fragment, present only in the second tautomeric form. An X-ray single-crystal study showed the compound (128) to be in a cyclic form. [Pg.102]

Similarly to the 2-norbornyl cation, comparison of calculated (IGLO/DZ//MP2/ 6-31G(d)) and experimental 13C NMR chemical shifts allowed to differentiate between the hypercoordinated 70 and the trivalent form 71 of the bicyclo[2.1.1.]hexyl cation.85 The experimental (157.8 ppm) and calculated (158.5 ppm) values for Cl and C2 (averaged signal) are reported to be nearly identical for the symmetrically bridged... [Pg.149]

Fig. 2.9.12. (bottom) APCI-LC-MS(+) RIC with insets of averaged mass spectra of selected signals, (top) Separation efficiency obtained by averaged signals is presented in... [Pg.275]

Dynamic intramolecular rearrangements are observed for a variety of diene-metal complexes at, or near, ambient temperature. This stereochemical non-rigidity may be detected by variable temperature NMR experiments40 in which the signals observed for a static structure coalesce into time averaged signals for the fluxional process. For purposes of this section, processes with activation energies > ca 25 kcal mol 1 or which are irreversible will be considered to be isomerization phenomena and will be discussed in Section IV. [Pg.894]


See other pages where Average signal is mentioned: [Pg.595]    [Pg.51]    [Pg.123]    [Pg.123]    [Pg.124]    [Pg.569]    [Pg.190]    [Pg.190]    [Pg.630]    [Pg.34]    [Pg.37]    [Pg.44]    [Pg.440]    [Pg.2]    [Pg.94]    [Pg.244]    [Pg.16]    [Pg.122]    [Pg.100]    [Pg.326]    [Pg.17]    [Pg.331]    [Pg.251]    [Pg.99]    [Pg.7]    [Pg.308]    [Pg.179]    [Pg.72]    [Pg.76]    [Pg.80]    [Pg.277]    [Pg.3]    [Pg.101]    [Pg.108]    [Pg.15]   
See also in sourсe #XX -- [ Pg.62 ]




SEARCH



Ensemble signal-averaging

Jitter free streak camera signal averaging

Nuclear magnetic resonance signal averaging

Nuclear magnetic resonance spectroscopy signal averaging

Signal averaged ECG

Signal averaging

Signal averaging

Signal averaging devices

Signal averaging solid-state

Signal averaging techniques

Signal averaging, FT-NMR

Signal averaging, accumulation

Signal averaging, effect

© 2024 chempedia.info