Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Applications to selected systems

In this section some of the essentials stated in the previous sections are reviewed and summarised. The equations derived are demonstrated for some [Pg.102]


In the writing of this review we have not sought to cover every aspect of the dielectric properties of colloidal systems. Our aim has rather been to demonstrate die usefidness of dielectric spectroscopy for such systems, using die application to selected systems as illustrations. [Pg.110]

Cl methods [21] add a certain number of excited Slater determinants, usually selected by the excitation type (e.g. single, double, triple excitations), which were initially not present in the CASSCF wave function, and treat them in a non-perturbative way. Inclusion of additional configurations allows for more degrees of freedom in the total wave function, thus improving its overall description. These methods are extremely costly and therefore, are only applicable to small systems. Among this class of methods, DDCI (difference-dedicated configuration interaction) [22] and CISD (single- and double excitations) [21] are the most popular. [Pg.156]

Typical applications for these high speed IR detectors are characterized by strictly controlled, dark environments where a flash fire could originate. While simple high speed infrared systems have been available for several years, modern sensor and filter developments, coupled with state-of-the-art electronics, have resulted in systems tailored for the munitions industry. These systems are more selective within the electromagnetic spectrum, fast in response, and extremely flexible in application to suppression systems. [Pg.192]

For AMBER, BIO +, or OPLS (energy calculation of biomacromolecules) Choose Constant (for systems in a gas phase or in an explicit solvent) or Distance dependent (to approximate solvent effects in the absence of an explicit solvent) and set Scale factor for Dielectric permittivity ( 1.0 with the default of 1.0 being applicable to most systems). Select either Switched or Shifted for Cutoffs and set Electrostatic (the range is 0 to 1 use 0.5 for... [Pg.304]

The usefulness of bimetallic systems in catalytic studies was mentioned in Section 1.6, and their preparation is surveyed in Sections 3.2.3 and 4.6 their beneficial application to selective oxidation of organic molecules is particularly stressed in Sections 8.3-8.5. [Pg.35]

This volume which deals with rapid radiochemical separations Is the fourth In a series of monographs on radiochemical techniques which will parallel the series on the radiochemistry of the elements. The same general style Is used in both series of monographs, Including general reviews of the technique, discussions of the principles involved, a detailed survey of applications to different systems, and a collection of selected procedures which use this technique as reported in the literature. [Pg.6]

A. I. Kalinitchev, in Chapter 4, deals with the kinetics of ion exchange in selective systems. In particular he uses the kinetic model developed in his research to show that phenomenological regularities and criteria describing intraparticle diffusion kinetics for conventional ion exchange are not applicable to selective ion-exchange systems. [Pg.454]

The first application on a biological system was performed in the mid-90 s on a gas phase cluster model of the active site of superoxide dismutase [11]. Since then a rapidly increasing number of applications to biological systems have been reported. In this article, we are trying to give an overview of the current status by giving a short outline of the studies that appeared so far in the literature and by presenting selected examples from our own work on enzymatic systems. [Pg.216]

Efficient iontophoretic delivery depends on the materials and excipients used in the system. Selection of appropriate electrodes and formulations are critical to maximizing the efficiency of iontophoretic treatments. The following sections will summarize key criteria for selection of electrodes and formulations for transdermal applications, however, many of the same principles are applicable to iontophoretic systems used on mucosa or implanted within the body. [Pg.2121]


See other pages where Applications to selected systems is mentioned: [Pg.171]    [Pg.102]    [Pg.103]    [Pg.105]    [Pg.107]    [Pg.109]    [Pg.111]    [Pg.113]    [Pg.115]    [Pg.117]    [Pg.1128]    [Pg.147]    [Pg.171]    [Pg.102]    [Pg.103]    [Pg.105]    [Pg.107]    [Pg.109]    [Pg.111]    [Pg.113]    [Pg.115]    [Pg.117]    [Pg.1128]    [Pg.147]    [Pg.22]    [Pg.14]    [Pg.984]    [Pg.124]    [Pg.120]    [Pg.284]    [Pg.244]    [Pg.269]    [Pg.710]    [Pg.209]    [Pg.67]    [Pg.20]    [Pg.20]    [Pg.21]    [Pg.339]    [Pg.36]    [Pg.534]    [Pg.12]    [Pg.984]    [Pg.78]    [Pg.96]    [Pg.52]    [Pg.71]    [Pg.94]    [Pg.708]    [Pg.21]    [Pg.655]    [Pg.358]   


SEARCH



Applications system

Select Applications

Selected applications

Selective applications

© 2024 chempedia.info