Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Apparatus high intensity system

Another method for measuring thermal diffusivity is the flash method developed by Parker et al. [48] and successfully used for the thermal diffusivity measurement of solid materials [49]. A high intensity short duration heat pulse is absorbed in the front surface of a thermally insulated sample of a few millimeters thick. The sample is coated with absorbing black paint if the sample is transparent to the heat pulse. The resulting temperature of the rear surface is measured by a thermocouple or infrared detector, as a function of time and is recorded either by an oscilloscope or a computer having a data acquisition system. The thermal diffusivity is calculated from this time-temperature curve and the thickness of the sample. This method is commercialized now, and there are ready made apparatus with sample holders for fluids. There is only one publication on nanofluids with this method. Shaikh et al. [50] measured thermal conductivity of carbon nanoparticle doped PAO oil. [Pg.149]

One of the problems of gas cleaning devices is to provide apparatus of intense action with high capacity for gas. This is associated with a reduction in the dimensions of the gas cleaning systems. [Pg.100]

The first element, dynamic dilution, provides a reproducible sample for each panelist. The system must minimize the loss of the odorant to the walls of the delivery apparatus, provide clean dilution air of odor-free quality, maintain a constant dilution ratio for the duration of a given test, and have no memory effect when going from high to low concentrations or switching between odorants of different character. The type of mask or port and the delivery flow rate have been found to influence the response of panelists in determining odor threshold and intensity. [Pg.207]

The basis of the experimental femtosecond CARS apparatus developed by Okamoto and Yoshihara (1990) which is reproduced in Fig. 3.6-10 is essentially the same as that of Leonhardt et al. (1987) and Zinth et al. (1988) with the addition of the possibility to change the polarization of the laser radiation. The main parts of the system are two dye lasers with short pulses and high repetition rates, pumped by a cw mode-locked Nd YAG laser (1064 nm, repetition rate 81 MHz). The beam of the first dye-laser which produces light pulses with 75-100 fsec duration is divided into two parts of equal intensities and used as the pump and the probe beam. After fixed (for the pump beam) and variable (for the probe beam) optical delay lines, the radiation is focused onto the sample together with the Stokes radiation produced by the second laser (DL2), which is a standard synchronously pumped dye laser. The anti-Stokes signal generated in the sample is separated from the three input laser beams by an aperture, an interference filter, and a monochromator, and detected by a photomultiplier. For further details we refer to Okamoto and Yoshihara (1990). [Pg.178]


See other pages where Apparatus high intensity system is mentioned: [Pg.71]    [Pg.236]    [Pg.118]    [Pg.9]    [Pg.10]    [Pg.198]    [Pg.529]    [Pg.192]    [Pg.114]    [Pg.222]    [Pg.233]    [Pg.111]    [Pg.599]    [Pg.350]    [Pg.38]    [Pg.538]    [Pg.130]    [Pg.500]    [Pg.457]    [Pg.95]    [Pg.322]    [Pg.10]    [Pg.129]    [Pg.191]    [Pg.840]    [Pg.104]    [Pg.645]    [Pg.51]    [Pg.50]    [Pg.81]    [Pg.123]    [Pg.457]    [Pg.182]    [Pg.25]    [Pg.280]    [Pg.136]    [Pg.7]    [Pg.228]    [Pg.424]    [Pg.215]    [Pg.182]    [Pg.11]    [Pg.92]    [Pg.96]    [Pg.229]    [Pg.220]    [Pg.179]   
See also in sourсe #XX -- [ Pg.288 ]




SEARCH



High Intensity Systems

© 2024 chempedia.info