Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analytical gradients total

In periodic systems, the ceU dimensions are a set of optimized structure parameters additional to nuclear coordinates in the primitive unit cell. Nowadays, the majority of solid-state codes compute the total energy with KS PW methods. In KS PW calculations the analytical gradients of total energy for nuclear coordinates and cell-parameter optimization are implemented in computer codes and widely used in the... [Pg.393]

We intentionally do not give here the mathematical details of the approaches allowing implementation of analytical gradients in the calculations of periodic systems (for these details readers are referred to the cited publications and references therein). We note that such an implementation is essentially more complicated than in the case of molecular systems and requires high accmacy in the total-energy calculation. One can find the detailed analysis of the accuracy in gradients calculations on numerical examples in [660,661,663]. The comparison of the numerical and analytical derivatives values can also be found. In what follows we turn to the results obtained for the equilibrium structure and cohesion energy in the crystalline metal oxides. The LCAO calculations discussed were made with the CRYSTAL code and use of HF, KS and hybrid Hamiltonians. [Pg.394]

In order to conserve the total energy in molecular dynamics calculations using semi-empirical methods, the gradient needs to be very accurate. Although the gradient is calculated analytically, it is a function of wavefunction, so its accuracy depends on that of the wavefunction. Tests for CH4 show that the convergence limit needs to be at most le-6 for CNDO and INDO and le-7 for MINDO/3, MNDO, AMI, and PM3 for accurate energy conservation. ZINDO/S is not suitable for molecular dynamics calculations. [Pg.123]

Vibrational spectroscopy is of utmost importance in many areas of chemical research and the application of electronic structure methods for the calculation of harmonic frequencies has been of great value for the interpretation of complex experimental spectra. Numerous unusual molecules have been identified by comparison of computed and observed frequencies. Another standard use of harmonic frequencies in first principles computations is the derivation of thermochemical and kinetic data by statistical thermodynamics for which the frequencies are an important ingredient (see, e. g., Hehre et al. 1986). The theoretical evaluation of harmonic vibrational frequencies is efficiently done in modem programs by evaluation of analytic second derivatives of the total energy with respect to cartesian coordinates (see, e. g., Johnson and Frisch, 1994, for the corresponding DFT implementation and Stratman etal., 1997, for further developments). Alternatively, if the second derivatives are not available analytically, they are obtained by numerical differentiation of analytic first derivatives (i. e., by evaluating gradient differences obtained after finite displacements of atomic coordinates). In the past two decades, most of these calculations have been carried... [Pg.146]

After sample loading, the cation-exchange RAM-column was placed in-line with the analytical cation-exchange column and analytes were eluted with a salt gradient. A total of 24 fractions of 4 min duration (2 mL of eluent) were transferred to the... [Pg.213]

In order to evaluate pump flow rate reproducibility and pulsation, one method is commonly used to assess gradient formation capability. A certain amount of an analyte with adequate molar absorptivity at the wavelength employed for detection is introduced into one of the mobile phases employed to create the gradient. In the case described, 5% acetone was introduced into the mobile phase, distributed to the system by pump B. No UV-absorbing analyte was introduced into mobile phase A. The fractional flow rate of pump B relative to the total flow rate of the system (mandated by the sum of the flow rates of pumps A and B) was increased in individual steps to account for 0, 3,6,12.5,25, 50, and 100% fractional rates. The total flow for the system was maintained at 300 /jL/ min (for 24 columns), resulting in a per column flow rate of 12.5 /iL/min/column. [Pg.167]


See other pages where Analytical gradients total is mentioned: [Pg.89]    [Pg.462]    [Pg.139]    [Pg.527]    [Pg.209]    [Pg.36]    [Pg.104]    [Pg.494]    [Pg.112]    [Pg.267]    [Pg.248]    [Pg.151]    [Pg.5]    [Pg.225]    [Pg.390]    [Pg.494]    [Pg.5]    [Pg.2]    [Pg.105]    [Pg.319]    [Pg.99]    [Pg.661]    [Pg.112]    [Pg.393]    [Pg.394]    [Pg.394]    [Pg.565]    [Pg.547]    [Pg.109]    [Pg.267]    [Pg.286]    [Pg.79]    [Pg.426]    [Pg.21]    [Pg.65]    [Pg.253]    [Pg.493]    [Pg.347]    [Pg.297]    [Pg.121]    [Pg.168]    [Pg.262]    [Pg.290]    [Pg.670]    [Pg.366]   
See also in sourсe #XX -- [ Pg.301 , Pg.305 , Pg.314 , Pg.316 , Pg.320 ]




SEARCH



Analytical gradients

Analytical total

© 2024 chempedia.info