Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Affective methods

Where specific drugs have been demonstrated to Interfere with chemical reactions, patients should be maintained free of these drugs for at least 72 hours before collecting the specimen. Other analytical techniques, e.g. column chromatography and radioimmunoassay procedures, can also be substituted for an affected method. [Pg.275]

Reference Standard. One of the limitations of the external standard method is that a well-characterized reference standard is essential. In addition, each analysis requires accurate weighings of small quantities (e.g., 10 mg) of reference standard. Therefore, weighing error can affect method precision and accuracy. [Pg.32]

In conclusion, while we pass over data we deem unreliable due to the use of bias-affected methods, the data provided by Leon-Ruiz et al. and Ciulu et al. demonstrate that the floral and geographical origins of the honey are important parameters influencing the concentration of ascorbic acid in this matrix. [Pg.215]

Sulfates may be differentiated from sulfonates by analyzing with and without acid hydrolysis. Sulfates are decomposed by this treatment, while sulfonates are not affected. Methods for analysis of these compounds are summarized in Table 3. [Pg.347]

The cloud point, usually between 0 and -10°C, is determined visually (as in NF T 07-105). It is equal to the temperature at which paraffin crystals normally dissolved in the solution of all other components, begin to separate and affect the product clarity. The cloud point can be determined more accurately by differential calorimetry since crystal formation is an exothermic phenomenon, but as of 1993 the methods had not been standardized. [Pg.214]

With this testing method an evaluation is possible within shortest time, i.e. directly after the heat impulse. The high temperature difference between a delamination and sound material is affected - among other parameters - by the thickness of the layer. Other parameters are size and stage of the delamination Generally, a high surface temperature refers to a small wall thickness and/or layer separation [4],... [Pg.405]

In situ control and calibration of flare and other gas metering systems is performed by gaseous tracers using the transit time method without affecting the normal production. Details about methodology are given in / /. [Pg.1054]

At this point it is worth comparing the different techniques of contrast enliancements discussed so far. They represent spatial filtering teclmiques which mostly affect the zeroth order dark field microscopy, which eliminates the zeroth order, the Schlieren method (not discussed here), which suppresses the zerotii order and one side band and, finally, phase contrast microscopy, where the phase of the zeroth order is shifted by nil and its intensity is attenuated. [Pg.1663]

Detection of cantilever displacement is another important issue in force microscope design. The first AFM instrument used an STM to monitor the movement of the cantilever—an extremely sensitive method. STM detection suffers from the disadvantage, however, that tip or cantilever contamination can affect the instrument s sensitivity, and that the topography of the cantilever may be incorporated into the data. The most coimnon methods in use today are optical, and are based either on the deflection of a laser beam [80], which has been bounced off the rear of the cantilever onto a position-sensitive detector (figme B 1.19.18), or on an interferometric principle [81]. [Pg.1693]

McCormack D A, Kroes G J and Neuhauser D 1998 Resonance affected scattering Comparison of two hybrid methods involving filter diagonalization and the Lanczos method J. Chem. Phys. 109 5177... [Pg.2326]

It is often the case that the solvent acts as a bulk medium, which affects the solute mainly by its dielectric properties. Therefore, as in the case of electrostatic shielding presented above, explicitly defined solvent molecules do not have to be present. In fact, the bulk can be considered as perturbing the molecule in the gas phase , leading to so-called continuum solvent models [14, 15]. To represent the electrostatic contribution to the free energy of solvation, the generalized Bom (GB) method is widely used. Wilhin the GB equation, AG equals the difference between and the vacuum Coulomb energy (Eq. (38)) ... [Pg.364]

Thus, a list of 1 5 descriptors was calculated for these purposes, as described below. The partition coefficient log P (calculated by a method based on the Gho.sc/Crip-pen approach [11]) (see also Chapter X, Section 1.1 in the Handbook) was calculated because it affects the solubility dramatically [17, 18]. All the other descriptors were calculated with the program PETRA (Parameter Estimation for the Treatment of Reactivity Applications) [28. ... [Pg.498]

The Microstate Cl Method lowers the energy of the tin correlated groun d state as well as excited states, fhe Sngly Eixcitecl Cl Method is particularly appropriate for calculating LIV visible spectra, and does not affect the energy of the ground state (Brillouin s fheo-rem). [Pg.39]


See other pages where Affective methods is mentioned: [Pg.111]    [Pg.26]    [Pg.1701]    [Pg.5]    [Pg.450]    [Pg.851]    [Pg.35]    [Pg.1128]    [Pg.34]    [Pg.1629]    [Pg.773]    [Pg.633]    [Pg.111]    [Pg.26]    [Pg.1701]    [Pg.5]    [Pg.450]    [Pg.851]    [Pg.35]    [Pg.1128]    [Pg.34]    [Pg.1629]    [Pg.773]    [Pg.633]    [Pg.315]    [Pg.721]    [Pg.577]    [Pg.482]    [Pg.838]    [Pg.1664]    [Pg.1771]    [Pg.1868]    [Pg.1869]    [Pg.1877]    [Pg.2202]    [Pg.2204]    [Pg.2332]    [Pg.2333]    [Pg.3028]    [Pg.578]    [Pg.79]    [Pg.244]    [Pg.384]    [Pg.37]    [Pg.56]    [Pg.74]   


SEARCH



Aspects of Processing Methods and Conditions Affecting Percolation Networks

Concentration factors affecting method selection

Factors affecting method choice

© 2024 chempedia.info