Adjustable peak detection

Dedicated software supports rather sophisticated techniques. For instance, peak detection enables adjustment of the time for transfer to GC to signals recorded by the LC detector, thus compensating for shifts in retention times. [Pg.1880]

Liquid chromatography was performed on symmetry 5 p.m (100 X 4.6 mm i.d) column at 40°C. The mobile phase consisted of acetronitrile 0.043 M H PO (36 63, v/v) adjusted to pH 6.7 with 5 M NaOH and pumped at a flow rate of 1.2 ml/min. Detection of clarithromycin and azithromycin as an internal standard (I.S) was monitored on an electrochemical detector operated at a potential of 0.85 Volt. Each analysis required no longer than 14 min. Quantitation over the range of 0.05 - 5.0 p.g/ml was made by correlating peak area ratio of the dmg to that of the I.S versus concentration. A linear relationship was verified as indicated by a correlation coefficient, r, better than 0.999. [Pg.395]

The main problem using planar methods is the difficulty in detection and collection of fractions among other less critical problems, such as homogeneous preparation of chromatographic media. However, the detection problem exists also for the coupled-column methods, mainly because of fraction dilution by each stage in a multidimensional separation system. Another aspect is the adjustment of chromatographic time bases between the different dimensions so that first-dimension peaks may be sampled an adequate number of times by the next dimension separation system. This aspect has been recently studied in detail (Murphy et al., 1998), and is covered in detail in Chapters 2 and 6. [Pg.389]

Although the pharmacokinetics of rifaximin in patients with renal insufficiency has not been specifically studied, its very low renal excretion makes any dose adjustment unnecessary. The same holds true for patients with hepatic insufficiency. In fact, the mean peak drug plasma concentrations (i.e. 13.5 ng/ml) detected in subjects with hepatic encephalopathy patients given rifaximin 800 mg 3 times daily for 7 days [34, 108] were not dissimilar to those found in healthy subjects [102] and patients with IBD [98], Indeed, in all the trials performed in this condition the drug has been well tolerated [33, 77],... [Pg.47]

Van den Berg [131] used this technique to determine nanomolar levels of nitrate in seawater. Samples of seawater from the Menai Straits were filtered and nitrite present reacted with sulfanilamide and naphthyl-amine at pH 2.5. The pH was then adjusted to 8.4 with borate buffer, the solution de-aerated, and then subjected to absorptive cathodic stripping voltammetry. The concentration of dye was linearly related to the height of the reduction peak in the range 0.3-200 nM nitrate. The optimal concentrations of sulfanilamide and naphthyl-amine were 2 mM and 0.1 mM, respectively, at pH 2.5. The standard deviation of a determination of 4 nM nitrite was 2%. The detection was 0.3 nM for an adsorption time of 60 sec. The sensitivity of the method in seawater was the same as in fresh water. [Pg.88]

Therefore, self-monitoring by the use of home peak expiratory flow meters is an essential part of the therapeutic program. With proper education, the patient can detect early signs of deterioration and can adjust medication within the framework of a physician-directed therapeutic regimen. [Pg.328]


See other pages where Adjustable peak detection is mentioned: [Pg.356]    [Pg.356]    [Pg.600]    [Pg.119]    [Pg.357]    [Pg.445]    [Pg.66]    [Pg.26]    [Pg.204]    [Pg.43]    [Pg.109]    [Pg.332]    [Pg.36]    [Pg.1322]    [Pg.75]    [Pg.96]    [Pg.182]    [Pg.221]    [Pg.147]    [Pg.240]    [Pg.271]    [Pg.43]    [Pg.95]    [Pg.430]    [Pg.755]    [Pg.763]    [Pg.327]    [Pg.245]    [Pg.134]    [Pg.426]    [Pg.124]    [Pg.725]    [Pg.203]    [Pg.73]    [Pg.363]    [Pg.349]    [Pg.541]    [Pg.254]    [Pg.255]    [Pg.433]    [Pg.191]    [Pg.188]    [Pg.286]    [Pg.165]    [Pg.95]   