Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Absorption traps

Dihydroxyacetophenone. Finely powder a mixture of 40 g. of dry hydroquinone diacetate (1) and 87 g. of anhydrous aluminium chloride in a glass mortar and introduce it into a 500 ml. round-bottomed flask, fitted with an air condenser protected by a calcium chloride tube and connected to a gas absorption trap (Fig. II, 8, 1). Immerse the flask in an oil bath and heat slowly so that the temperature reaches 110-120° at the end of about 30 minutes the evolution of hydrogen chloride then hegins. Raise the temperature slowly to 160-165° and maintain this temperature for 3 hours. Remove the flask from the oil bath and allow to cool. Add 280 g. of crushed ice followed by 20 ml. of concentrated hydrochloric acid in order to decompose the excess of aluminium chloride. Filter the resulting solid with suction and wash it with two 80 ml. portions of cold water. Recrystallise the crude product from 200 ml. of 95 per cent, ethanol. The 3 ield of pure 2 5-dihydroxyacetophenone, m.p. 202-203°, is 23 g. [Pg.677]

Equip a 1 litre three-necked flask wdth a reflux condenser, a mechanical stirrer, and a cork carrying a dropping funnel and a thermometer which reaches nearly to the bottom of the flask connect the upper end of the condenser to an absorption trap (Fig. II, 8, 1). Place 100 g. of p-bromo-toluene (Section IV.62) in the flask and immerse the latter in an oil bath (colourless oil in a large beaker). Heat the bath until the temperature of the stirred p-broniotoluene reaches 105°. Illuminate the liquid with... [Pg.694]

The considerable quantities of hydrogen chloride and hydrogen bromide evolved are best handled by means of a gas-absorption trap.- The insertion of a calcium chloride tube between the trap and the reflux condenser is recommended. [Pg.59]

In a r-1. three-necked flask fitted with a mechanical stirrer, a reflux condenser, a thermometer, and a dropping funnel is placed LOO g. (0.58 mole) of -bromotoluene (Org. Syn. Coll. Vol. i, 131). The stem of the dropping funnel and the thermometer should reach nearly to the bottom of the flask. The upper end of the condenser is connected to a gas absorption trap (Org. Syn. 14, 2). The flask is heated with stirring in an oil bath until the temperature of the liquid reaches 105. The liquid is illuminated with an unfrosted 150-watt tungsten lamp, and 197 g. (61.8 cc., 1.23 moles) of bromine is added slowly from the separatory funnel (Note i). About one-half of the bromine is added during the first hour, during which time the temperature is kept at 105-110°. The rest is added during about two hours, while the temperature is raised to 135°. When all the bromine has been added the temperature is raised slowly to 150°. [Pg.20]

The reaction mixture and contents of the cold trap are then transferred (Note 7) to a 500-ml. distilling flask attached through a short fractionating column to a water-cooled condenser which is connected in series to a receiver, a trap cooled in a dry ice-acetone bath, and a hydrogen chloride absorption trap which may later be attached to a water pump. The mixture is then distilled until the pot temperature reaches 100° and practically all of the acetyl chloride has been driven over. [Pg.63]

Absolute Methyl Alcohol, 7, 28, 29 Absorption trap for gases, 8, 26, 28 Acetal, 3,1 Acetaladon, 3,1... [Pg.129]

The apparatus should be set up under a hood, or the top of the condenser connected to a gas absorption trap for the removal of bromine vapor, a small amount of which escapes continually under the conditions of the experiment. [Pg.18]

In a dry 2-1. three-necked round-bottomed flask, fitted with a gas-tight stirrer and a reflux condenser carrying at the top a calcium chloride drying tube connected to a gas-absorption trap (a good hood is preferable), are placed 98.5 g. (0.6 mole) of... [Pg.46]

A 5-1. three-necked flask is fitted with a mechanical rubbersleeved stirrer, a dropping funnel, and a reflux condenser capped with a calcium chloride tube leading to a gas-absorption trap.2 The system is flame-dried, and the flask is charged with 308 g. (1 mole) of dibromohydrocinnamic acid (Note 1) and 800 ml. of dried (by distillation) thiophene-free benzene. While the dibromohydrocinnamic acid is maintained in suspension by stir-... [Pg.50]

A 500-ml. three-necked round-bottomed flask is provided with a small dropping funnel, a sealed mechanical stirrer, a reflux condenser connected to a gas-absorption trap, and a hydrogen chloride delivery tube which extends, to the bottom of the flask. [Pg.75]

In a 5-1. three-necked, round-bottomed flask, fitted with a sealed stirrer, dropping funnel, and air condenser, the open end of which is connected to a gas-absorption trap, arc placed 188 g. (2 moles) of phenol and 268 g. (2 moles) of ethyl acetoacetate in... [Pg.97]

The acidic gases may be absorbed in 10% NaOH solution using the absorption trap as described in Org. Synth., Coll. Vol. /1941, 97. [Pg.162]

A) 2-Bromophthalide.—The apparatus shown in Fig. 6 is used for the bromination. Flasks A and B are of 200-cc. capacity. Bromine is introduced by means of a current of carbon dioxide, which passes through mineral oil or sulfuric acid in the bubble counter, then through the bromine in flask B, and finally through the drying tower. The tower is conveniently made from a condenser jacket and is filled with anhydrous calcium chloride. Flask A is surrounded by an oil bath and is equipped with a thermometer, an outlet tube of wide bore connected to a gas absorption trap, and a gas inlet tube having an inside diameter of 2 mm. The inlet tube reaches to the bottom of the flask. [Pg.37]

A. 2-Chloro-2-methylcyclohexanone. A 3-1. three-necked flask, fitted with a sealed mechanical stirrer with glass blade, a dropping funnel, and an outlet tube connected to a gas-absorption trap,1 2 is charged with... [Pg.5]

In a 2-1., three-necked, round-bottomed flask (Note 1) fitted with a sealed stirrer having a Teflon blade and, on the two side necks, with gas-outlet tubes connected by rubber or plastic tubing to an etficient hydrogen chloride absorption trap (Note 2), 464 g. (2 moles) of D,L-10-camphorsulfonic acid (Note 3) is mixed with 416 g. (2 moles) of phosphorus pentachloride (Note 4). The flask is immersed in ice water and, as soon as the mixture has liquefied sufficiently, the stirrer is started but must be run slowly at first because of lumps. When the vigorous reaction has subsided, the cooling bath is removed and stirring continued until the chloride is completely dissolved (Note 5). The mixture is then allowed to stand for 3 or 4 hours. It is poured Hood ) onto 500 g. of crushed ice contained in a 2-1. beaker. This mixture is immediately poured into a second beaker containing a similar quantity of crushed ice. The mixture is then poured back and forth between the two beakers until all evidence of reaction has disappeared (Note 6). The fine white product is collected on a... [Pg.8]

The preparation should be conducted in a well-ventilated hood or provision should be made for an exhaust tube and attachment to a gas-absorption trap. [Pg.102]

A mixture of 150 g. (2.5 moles) of urea, 125 g. (1.25 moles) of reprecipitated calcium carbonate, and 150 ml. of water in a 2-1. three-necked flask is tared and cooled in an ice-salt bath. The flask is equipped with a thermometer which extends into the reaction mixture, a gas inlet tube, an outlet tube leading to a gas-absorption trap, and a slip- or mercury-sealed mechanical stirrer which will disperse chlorine gas below the surface of the liquid (Note 1). [Pg.13]


See other pages where Absorption traps is mentioned: [Pg.71]    [Pg.738]    [Pg.739]    [Pg.854]    [Pg.902]    [Pg.961]    [Pg.978]    [Pg.988]    [Pg.61]    [Pg.81]    [Pg.738]    [Pg.739]    [Pg.854]    [Pg.902]    [Pg.961]    [Pg.978]    [Pg.988]    [Pg.1202]    [Pg.1093]    [Pg.28]    [Pg.35]    [Pg.81]    [Pg.83]    [Pg.28]    [Pg.31]    [Pg.47]    [Pg.54]    [Pg.98]   
See also in sourсe #XX -- [ Pg.38 ]




SEARCH



Absorption polymer trapping

Gas absorption traps

Ions, absorption, detection traps

Optical trapping energy absorption

Transmittance Traps, gas absorption

Trapped electron optical absorption band

© 2024 chempedia.info