Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

UV measurements

Spectroscopic methods such as uv and fluorescence have rehed on the polyene chromophore of vitamin A as a basis for analysis. Indirectly, the classical Carr-Price colorimetric test also exploits this feature and measures the amount of a transient blue complex at 620 nm which is formed when vitamin A is dehydrated in the presence of Lewis acids. For uv measurements of retinol, retinyl acetate, and retinyl palmitate, analysis is done at 325 nm. More sensitive measurements can be obtained by fluorescence. Excitation is done at 325 nm and emission at 470 nm. Although useful, all of these methods suffer from the fact that the method is not specific and any compound which has spectral characteristics similar to vitamin A will assay like the vitamin... [Pg.102]

In the polyazamacrocyclic phenols [64], an acidic function, the phenol group, has an intra-annular orientation while the basic units, the nitrogen atoms of the macrocycles, have no defined orientation. In water at 25°C, the pATa values of the phenols were measured and compared with those of other macrocyclic and non-macrocyclic phenols (Kimura et al., 1987a,b). Because the nitrogen atoms and the phenol function both possess acid-base properties, more than one pXg value could be measured. By the use of UV measurements, the values of the phenol group could be distinguished from those of the amines. [Pg.104]

Avdeef and Bucher [24] investigated the use of universal buffers in potentiomet-ric titrations. Recently, such a buffer system, formulated with several of the Good components, has been designed specifically for robotic applications, where automated pH control in 96-well microtiter plates is required, with minimal interference to the UV measurement [48]. This universal buffer has a nearly perfectly linear pH response to additions of standard titrant in the pH 3-10 region [8, 48]. [Pg.62]

There is much effort in the international community in relation to the topic of UV measurement and the calibration of UV measuring devices. For standards and best practice in absorption spectrometry,... [Pg.306]

C, elution chromatography, shake flask-UV, measured range 10-30°C, Schwarz Miller 1980) 181 (vapor saturation-UV, measured range 15 150C, Sanemasa et al. 1981)... [Pg.439]


See other pages where UV measurements is mentioned: [Pg.130]    [Pg.143]    [Pg.27]    [Pg.308]    [Pg.242]    [Pg.406]    [Pg.338]    [Pg.743]    [Pg.215]    [Pg.83]    [Pg.407]    [Pg.407]    [Pg.407]    [Pg.408]    [Pg.410]    [Pg.410]    [Pg.425]    [Pg.425]    [Pg.426]    [Pg.426]    [Pg.439]    [Pg.439]    [Pg.440]    [Pg.440]    [Pg.440]    [Pg.459]    [Pg.467]    [Pg.493]    [Pg.493]    [Pg.500]    [Pg.500]    [Pg.520]    [Pg.520]    [Pg.547]    [Pg.553]    [Pg.623]    [Pg.623]    [Pg.624]    [Pg.624]    [Pg.624]    [Pg.669]    [Pg.669]    [Pg.669]    [Pg.691]    [Pg.691]    [Pg.699]   
See also in sourсe #XX -- [ Pg.150 ]

See also in sourсe #XX -- [ Pg.148 ]

See also in sourсe #XX -- [ Pg.148 ]




SEARCH



Characterization and Measurement of Anthocyanins by UV-Visible Spectroscopy

Electrical conductivity and UV measurements

Method for Performing UV-Vis Spectroscopic Measurements

New Techniques in UV-visible Reflection Measurements

Remarks on the Scope for Future Development of UV-visible Reflection Measurements

Required Equipment for UV-Vis Measurements

UV Light (Fluorescence Measurement)

UV-Vis measurement

UV-vis spectrophotometric measurements

UV-vis. spectroscopic measurements

UV-visible reflection measurement

© 2024 chempedia.info