Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Underflow Pumping

Rake-Lifting Mechanisms These should be provided when abnormal thickener operation is probable. Abnormal thickener operation or excessive torque may result from insufficient underflow pumping, surges in the solids feed rate, excessive amounts of large particles, sloughing of solids accumulated between the rakes and the bottom of... [Pg.1686]

Overfill by plugging, blinding cloth, failure to start underflow pump, loss of vacuum or by operator error. [Pg.103]

There are several basic underflow arrangements (1) the underflow pump adjacent to the thickener sidewall with buried piping from the discharge cone, (2) the underflow pump under the thickeners or adjacent to the sidewall with the piping from the discharge cone in a tun-... [Pg.1509]

Underflow is usually withdrawn continuously on the bases of bed level, rake torque, or underflow solids concentration in a feed-back mode. Most installations incorporate at least two of these parameters in their underflow withdrawal control philosophy. For example, the continuous withdrawal may be based on underflow solids density with an override to increase the withdrawal rate if either the rake torque or the bed level reaches a preset value. In some cases, underflow withdrawal has been regulated in a feed-forward mode on the basis of thickener feed sohds mass flow rate. Any automated underflow pumping scheme should incorporate a lower limit on volumetric flow rate as a safeguard against line pluggage. [Pg.1509]

Stable thickener performance can be maintained by carefully monitoring operating conditions, particularly the pulp interface level and the underflow rate and concentration. As process changes occur, the pulp level can vary regulation of the underflow pumping rate will... [Pg.2008]

Tunnel A tunnel may be constructed under the thickener to provide access to the discharge cone when underflow slurries are difficult to pump and have characteristics that cause plugging. The underflow pump may be installed underneath the thickener or at the perimeter. Occasionally thickeners are installed on legs or piers, making tunneling for access to the center unnecessary. A tunnel or an elevated thickener is more expensive than the other underflow arrangements, but... [Pg.2013]

Another factor was the inability of the thickener underflow pumps (inappropriately sized for the service) to handle slurries containing much more than 15% solids. This required the dilution of the thickener underflow before being pumped to the filter. A much higher demand was then placed on the already limited capabilities of the filter. The slurry had to be dewatered from 15% solids to 55% instead of from 25 to 55% thus, more than doubling the amount of filtrate to be removed from the same amount of insoluble solids. [Pg.342]


See other pages where Underflow Pumping is mentioned: [Pg.35]    [Pg.1621]    [Pg.1681]    [Pg.1683]    [Pg.1683]    [Pg.1689]    [Pg.1690]    [Pg.653]    [Pg.1442]    [Pg.1502]    [Pg.1504]    [Pg.1504]    [Pg.1509]    [Pg.1509]    [Pg.1509]    [Pg.1509]    [Pg.1510]    [Pg.1511]    [Pg.1938]    [Pg.1938]    [Pg.2006]    [Pg.2008]    [Pg.2010]    [Pg.2013]    [Pg.2013]    [Pg.2013]    [Pg.2014]    [Pg.2014]    [Pg.2016]    [Pg.71]    [Pg.73]    [Pg.75]    [Pg.78]    [Pg.78]    [Pg.78]    [Pg.79]    [Pg.79]    [Pg.81]   


SEARCH



Decantation underflow pumping

Pumps, thickener underflow

Underflow

Underflow Pump Requirements

© 2024 chempedia.info