Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ultraviolet detector, quality

E. Naffrechoux, C. Fachinger, and J. Suptil. Diode-array ultraviolet detector for continuous monitoring of water-quality. Anal. Chim. Acta, 270 187-193,1992. [Pg.361]

The use of ultraviolet (UV) spectroscopy for on-line analysis is a relatively recent development. Previously, on-line analysis in the UV-visible (UV-vis) region of the electromagnetic spectrum was limited to visible light applications such as color measurement, or chemical concentration measurements made with filter photometers. Three advances of the past two decades have propelled UV spectroscopy into the realm of on-line measurement and opened up a variety of new applications for both on-line UV and visible spectroscopy. These advances are high-quality UV-grade optical fiber, sensitive and affordable array detectors, and chemometrics. [Pg.81]

Panderi and Parissi-Poulou developed a microbore liquid chromatographic method for the simultaneous determination of benazepril hydrochloride and hydrochlorothiazide in pharmaceutical dosage forms [30]. The use of a BDS C-18 microbore analytical column was found to result in substantial reduction in solvent consumption and in increased sensitivity. The mobile phase consisted of a mixture of 25 mM sodium dihydrogen phosphate buffer (pH 4.8) and acetonitrile (11 9 v/v), pumped at a flow rate of 0.4 mL/min. Detection was effected at 250 nm using an ultraviolet absorbance detector. The intra- and inter-day relative standard deviation values were less than 1.25% (n = 5), while the relative percentage error was less than 0.9% (n = 5). The detection limits obtained according to the IUPAC definition were 0.88 and 0.58 pg/mL for benazepril hydrochloride and hydrochlorothiazide, respectively. The method was applied to the quality control of commercial tablets and content uniformity test, and proved to be suitable for rapid and reliable analysis. [Pg.150]


See other pages where Ultraviolet detector, quality is mentioned: [Pg.572]    [Pg.704]    [Pg.139]    [Pg.354]    [Pg.569]    [Pg.133]    [Pg.265]    [Pg.160]    [Pg.205]    [Pg.3008]    [Pg.202]    [Pg.517]    [Pg.752]    [Pg.125]    [Pg.69]    [Pg.3007]    [Pg.317]    [Pg.213]    [Pg.4248]    [Pg.288]    [Pg.357]    [Pg.1818]    [Pg.180]    [Pg.279]    [Pg.3294]    [Pg.130]    [Pg.445]    [Pg.210]   
See also in sourсe #XX -- [ Pg.30 ]




SEARCH



Ultraviolet detectors

© 2024 chempedia.info