Transmission detectors

As an alternative, changes in relative intensity of the laser lines may be directly recorded using for example, reflection images or a transmission detector, and y may be adjusted accordingly. In our experience, this works significantly less reliable. [Pg.329]

Detectors for quantitative measurement of X-ray absorption spectra must measure the flux (photons s of the X-ray beam. Ionization chambers consisting of X-ray transparent windows on each end of a chamber holding an inert gas work well as transmission detectors for concentrated samples. For transmission detectors, ln(/o//) is proportional to the absorption coefficient of the absorbing atom, p (/o = incident X-ray photon intensity, /= transmitted intensity), according to Beer s Law ... [Pg.80]

Figure 21 Artist s depiction of a system for imaging scattered X-rays. A fixed collimator slit and a rotating collimator slit produce a scanning pencil beam. A transmission detector monitors the transmitted beam, whereas large-area detectors respond to forward-scattered and backscattered X-rays emanating from the bag. Figure 21 Artist s depiction of a system for imaging scattered X-rays. A fixed collimator slit and a rotating collimator slit produce a scanning pencil beam. A transmission detector monitors the transmitted beam, whereas large-area detectors respond to forward-scattered and backscattered X-rays emanating from the bag.
Fig. 1. Construction principle la Tungsten or halogen lamp, b deuterium lamp, c mercury lamp, d xenon lamp 2a monochromator, b filter 3 chromatoplate, 4a reflectance detector, b transmission detector... Fig. 1. Construction principle la Tungsten or halogen lamp, b deuterium lamp, c mercury lamp, d xenon lamp 2a monochromator, b filter 3 chromatoplate, 4a reflectance detector, b transmission detector...
In the AE — E telescope, the dual ADC, that converts the signals of both detectors, is activated by the pulses from the stop detector. The most important reason for this choice is that the hydrogen recoils do not lose enough energy in the transmission detector to generate measurable pulses. It has also... [Pg.160]

Using a combination of X-ray and transmission detectors greatly extends the scope of a system, enabling it to deal with the most common types of plastics entering the waste stream, from retail packaging sources polyethylene, polypropylene, PET, polystyrene, and PVC. [Pg.242]

The STEM/CTEM is complicated, as the same lenses are used for two tasks. A special objective lens used in STEM/CTEM can be highly excited, that is it can have large magnetic fields, or more technically, k > > [5]. The part of the field before the specimen then acts as a third condenser. The remainder of the field continues to act as a magnifying lens, reducing the divergence of the probe and allowing transfer of electrons to the transmission detector, which is located below the fluorescent screen. In this case the condenser/objective is critical in both modes of operation for STEM mode it will be referred to as the final condenser. [Pg.54]


See other pages where Transmission detectors is mentioned: [Pg.637]    [Pg.349]    [Pg.152]    [Pg.70]    [Pg.105]    [Pg.80]    [Pg.614]    [Pg.551]    [Pg.581]    [Pg.608]    [Pg.202]    [Pg.150]    [Pg.548]    [Pg.4621]    [Pg.159]    [Pg.167]    [Pg.293]    [Pg.1073]    [Pg.60]    [Pg.359]    [Pg.405]    [Pg.86]   