Thermospray interface disadvantages

The advantages and disadvantages of this type of interface, particnlarly in comparison to the moving-belt interface which was available at the same time, are listed below. This was one of the first LC-MS interfaces to be made commercially available and, although used in a number of laboratories, its development was halted premamrely by the introduction of the thermospray interface (as we shall see later). [Pg.143]

A large number of LC-MS systems are equipped with a thermospray interface, which can accept LC flow rates up to ImL/min and is especially useful for the analysis of polar and nonvolatile molecules (18). The major disadvantage of this interface is the mass spectrum produced. The "classical" thermospray system only provides spectra with a single molecular ion and little structural information. Only when used with an additional element like a fragmentor electrode is it possible to obtain detailed information regarding the chemical structure of the molecule (19). [Pg.301]

The first commercially successful off-line DD-HPLC/FT-IR interface was the LC Transform, made by Lab Connections [41]. With this device, nebulization is initiated ultrasonicaUy and the solvent is evaporated with either a thermospray or a concentric flow nebulizer. The solutes are first deposited on a rotating germanium disk on the underside of which a thick layer of aluminum has been deposited. After the deposition step, the disk is then moved to a specular reflection accessory that is mounted in the sample compartment of a standard FT-IR spectrometer. The developers of the LC Transform recognized that it is more convenient to measure the spectra of the components that had been deposited on the disk by reflection spectrometry than by transmission. However, the deposition of a very thin film of each eluate on a metal substrate would not allow its reflection-absorption spectrum to be measured with adequate efficiency without resorting to grazing incidence measurements, for which the disadvantages were discussed in Section 23.3.3. [Pg.497]


See other pages where Thermospray interface disadvantages is mentioned: [Pg.372]    [Pg.825]    [Pg.950]    [Pg.506]    [Pg.85]    [Pg.735]   
See also in sourсe #XX -- [ Pg.98 ]