Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Target dimension

Dimensional and performance criteria should be provided. Dimensional information is frequently provided via a detailed schematic drawing, complete with target dimensions and tolerances, and it may be provided via the packaging component manufacturer s DMF. A separate draw-... [Pg.22]

Boards will be slightly narrower than maximum theoretical width as cutting IS to target dimensions. [Pg.248]

Bio-)pharmaceutical companies that start aligning themselves to these target dimensions today will be tomorrow s winners. They can become architects of sustainable solutions for a high-quality medical care, with a new credibility vis-a-vis patients, physicians and the system as a whole. [Pg.1712]

Composite materials are typically made using the above-mentioned fibers and fabrics, or other types, as well as a matrix material. A resin, such as epoxy, is used to impregnate the fabric and then the composite is heated to cure and harden. Sometimes pressure is applied to form the composite into a specific shape with exact target dimensions. In the case of unidirectional or fabric prepregs, the layers are stacked and then heated under pressure to form the composite. [Pg.362]

Microstructured fibers are usually fabricated by the stack-and-draw technique. Glassy capillaries are stacked and inserted into a jacketing tube to form a preform, which is then drawn. This step can be repeated to obtain target dimensions in the final fiber geometry. Alternatively, El-Amraoui et al. have recently prepared preforms with a variety of geometrical patterns by direct mechanical drilling of holes in the ChG rod [156]. [Pg.229]

Besides standard designs special GDC designs have been developed for registration of charge patterns upon the electrostatic paper with thermoplastic potential layers with an input semiconductor target, with a microchannel plate at the input and so on. The GDC design provided the basis for series production of GDC with maximum dimensions (500 x 600 mm ) and a service life above 5000 hours. [Pg.540]

However, it is common practice to sample an isothermal isobaric ensemble NPT, constant pressure and constant temperature), which normally reflects standard laboratory conditions well. Similarly to temperature control, the system is coupled to an external bath with the desired target pressure Pq. By rescaling the dimensions of the periodic box and the atomic coordinates by the factor // at each integration step At according to Eq. (46), the volume of the box and the forces of the solvent molecules acting on the box walls are adjusted. [Pg.368]

The dimensions of eaeii eomponent in the toieranee staek design (Figure 3.6), their respeetive materiais and manufaeturing proeesses are inputted in sequenee into CAPRAtol. Aiso required are the target assembiy toieranee and the FMEA Severity... [Pg.124]

Rating (S) to give the target Cp. The program initially ealeulates a primer toleranee, (the statistieal sum of the primer toleranees equals the assembly toleranee, and allo-eates this to eaeh dimension. The primer toleranees are ealeulated using equation 3.23, whieh is derived from equation 3.21. They are used to start the optimization routine and their respeetive risk values A are ealeulated from the proeess eapability maps ... [Pg.125]

Based on technical calculations the conditions achievable by different systems (ventilation, cleaning, etc.) are compared to target levels to identify acceptable systems. Dimensioning properties could be ... [Pg.34]

In common with all multidimensional separations, two-dimensional GC has a requirement that target analytes are subjected to two or more mutually independent separation steps and that the components remain separated until completion of the overall procedure. Essentially, the effluent from a primary column is reanalysed by a second column of differing stationary phase selectivity. Since often enhancing the peak capacity of the analytical system is the main goal of the coupling, it is the relationship between the peak capacities of the individual dimensions that is crucial. Giddings (2) outlined the concepts of peak capacity product and it is this function that results in such powerful two-dimensional GC separations. [Pg.46]


See other pages where Target dimension is mentioned: [Pg.1317]    [Pg.489]    [Pg.205]    [Pg.209]    [Pg.4]    [Pg.118]    [Pg.243]    [Pg.82]    [Pg.1738]    [Pg.1317]    [Pg.430]    [Pg.88]    [Pg.1910]    [Pg.538]    [Pg.221]    [Pg.1317]    [Pg.489]    [Pg.205]    [Pg.209]    [Pg.4]    [Pg.118]    [Pg.243]    [Pg.82]    [Pg.1738]    [Pg.1317]    [Pg.430]    [Pg.88]    [Pg.1910]    [Pg.538]    [Pg.221]    [Pg.513]    [Pg.888]    [Pg.1062]    [Pg.1803]    [Pg.1804]    [Pg.1990]    [Pg.52]    [Pg.442]    [Pg.412]    [Pg.375]    [Pg.195]    [Pg.196]    [Pg.271]    [Pg.33]    [Pg.35]    [Pg.40]    [Pg.130]    [Pg.164]    [Pg.197]    [Pg.229]    [Pg.37]    [Pg.565]   
See also in sourсe #XX -- [ Pg.17 ]




SEARCH



© 2024 chempedia.info