FIG. 18 66 Forced-circulation baffle surface-cooled crystallizer. (Swenson Process Equipment, Inc.)... [Pg.1665]

This type is similar in principle to the tank type, but the cooling surfaces are continually scraped or agitated to prevent the fouling by deposited crystals and to promote heat transfer. They are suitable for processing high-viscosity liquors. Scraped-surface crystallisers can be operated batchwise, with recirculation of the mother liquor, or continuously. A disadvantage of this type is that they tend to produce very small crystals. A typical unit is the Swenson-Walker crystalliser shown in Volume 2. [Pg.436]