Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Surface mounting, description

When Fig. 2.2 is used to describe surface-mount assemblies, the vertical (y-axis) dimension (shown as a vertical oval) indicates how complex it is to assemble the board by number of components per square inch or square centimeter for the surface area of the PWB. This vertical oval can vary from 1 to over 100 parts per square inch. As the parts become smaller and closer together, this number naturally goes up. A second assembly measme is average leads (I/Os) per square inch or square centimeter. This is the x-axis value multiplied by the y-axis value. (For a further description of these issues, and equations for quantifying them, see Chap. 18.)... [Pg.41]

In the following section constructural details of the Sequenator will be described to the extent required for an understanding of its operation. A detailed technical description has been published in 1967 by Edman and Begg ). Fig. 3 represents a diagrammatic view of the essential components of the instrument. The central part of the Sequenator is the reaction vessel (A), a cylindrical cup of pyrex glass mounted on the shaft of an electric motor (5). Correct functioning of this device requires that the inside cylindrical surface of the cup runs absolutely true. Variance would cause untolerable turbulence within the liquid film spread on the wall of the cup. An additional requirement is constant rotational speed of the cup. Variance of the speed would cause movement of the film up or down the wall. The cup is housed in a bell jar Q) which... [Pg.7]

Figure 12.28 shows the particle surface area size distribution before the Mount Pinatubo eruption (Fig. 12.28a), inside the main aerosol layer several months after the eruption (Fig. 12.28b), and almost two years after the eruption (Fig. 12.28c). (See Chapter 9.A.2 for a description of how particle size distributions are normally characterized.) Prior to the eruption, the surface area distribution is unimodal, with typical radii of 0.05-0.09 /xrn and a number concentration of l-20 particles cm 1. In the main stratospheric aerosol layer formed after the eruption, the distribution is bimodal... Figure 12.28 shows the particle surface area size distribution before the Mount Pinatubo eruption (Fig. 12.28a), inside the main aerosol layer several months after the eruption (Fig. 12.28b), and almost two years after the eruption (Fig. 12.28c). (See Chapter 9.A.2 for a description of how particle size distributions are normally characterized.) Prior to the eruption, the surface area distribution is unimodal, with typical radii of 0.05-0.09 /xrn and a number concentration of l-20 particles cm 1. In the main stratospheric aerosol layer formed after the eruption, the distribution is bimodal...
Under the microscope a crystal with desirable attributes (size, apparent crystallinity) is selected and cleaned. The crystal is then removed from the oil by lifting it out with a prepared mounting fiber (see below for description), and immediately transferred to the cold stream on the diffractometer. This step can often be simplified if the crystal is moved toward the surface of the oil before one attempts to pick it up. [Pg.260]

The risk of an adverse systemic reaction following skin contact with a potentially toxic chemical depends on the speed and total amount of absorption through the skin. Several techniques have been devised to measure these parameters across Isolated skin mounted In diffusion cells. The mathematical and kinetic relationships which define the operation of these various systems have been reviewed. A novel kinetic description of the penetration process has been developed and applied to skin absorption measurements for benzoic acid and paraquat. The results suggest that when these substances are deposited on the skin surface In a volatile solvent, a portion of the applied dose Is rapidly solubilized Into the skin and available for fast absorption, while the remainder Is absorbed more slowly. [Pg.18]

The metals were symmetrically mounted in a 400 ml beaker (Duran, Jena Glas). The beaker was then filled with freshly prepared buffer and placed in a water bath, at 37 + 1 °C. The metals were allowed to stabilize in the tempered buffer for 20 minutes before the protein was added by pipette into the centre of the volume. It is our experience from electrochemical experiments that it is necessary to allow the metals to stabilize in the phosphate buffer in order to obtain a stable open cell potential (rest potential) and thus an equilibrated surface. Magnetic stirring was performed at 100 rpm. A final fibrinogen solution of 0.4 mg/ml was then allowed to adsorb for 60 + 5 minutes. The final protein concentration was 1 mg/ml in the lysozyme and pepsin experiments. The yS-lactoglobulin sampies were prepared by adsorption from a 1 mg/ml solution (pH = 7.0+0.1) at 20°C. For a more detailed description of the adsorption process, see [24]. The samples were then copiously rinsed with distilled water and left to dry at room temperature for one week before the IR-analysis. [Pg.69]


See other pages where Surface mounting, description is mentioned: [Pg.922]    [Pg.1364]    [Pg.244]    [Pg.507]    [Pg.16]    [Pg.40]    [Pg.114]    [Pg.559]    [Pg.696]    [Pg.1035]    [Pg.123]    [Pg.171]    [Pg.370]    [Pg.559]    [Pg.220]    [Pg.559]    [Pg.261]    [Pg.427]    [Pg.516]    [Pg.78]    [Pg.100]    [Pg.8]    [Pg.341]    [Pg.9242]    [Pg.27]    [Pg.63]    [Pg.1466]    [Pg.142]    [Pg.454]   
See also in sourсe #XX -- [ Pg.380 , Pg.382 ]




SEARCH



Mount

Surface description

Surface mounting

© 2024 chempedia.info