Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Steel measurements

NaN3 content. Add 794 g NaOH in pellets. This quantity of caustic is supposed to be sufficient to keep neutralized most of the free acid formed during the interaction of lead nitrate soln for pptg LA. This quantity of NaOH is also just sufficient to control the purity of the finished LA, because it Fpts a small amt of lead as Pb(0H)a or Pb(OH)Ns. Adjust the concn of stock soln B to 3.175 0.025% NaN3 content. c)Drop 60 1 of stock soln B(10% in excess) from a 1000 1 storage tank to the stainless steel measuring tank of ca 100 1 capacity, where the soln is heated by means of hot water coils. Drop the preheated soln into the precipitator (reactor). [Pg.548]

This is a stainless steel round bottom spouted kettle of 120 1 capacity with a steel jacket and four-bladed stainless steel agitator which rotates at 95 RPM. d)Raise and maintain the temp of soln A at 135-140°F (57.5-60°) by circulating 170°F (ca 76.5°) water through the jacket of the reactor. e)Drop 50 1 of stock soln B/NaNj from the 1000 1 storage tank to a second stainless steel measuring tank of... [Pg.548]

A set of plastic or stainless steel measuring spoons will facilitate transferring chemicals from the bottle to the scales. They will help to prevent wasteful spills, which can cause contamination. Do not overfill the spoon transfer a little at a time to prevent spilling. [Pg.166]

Figure 3 Potentiodynamic polarization curves from a 0.003% S austentic stainless steel measured in 1 M NaCl with capillaries of differing size. (From T. Suter, T. Peter, H. Bohni. Mater. Sci. Forum, 192-194, 25 (1995).)... Figure 3 Potentiodynamic polarization curves from a 0.003% S austentic stainless steel measured in 1 M NaCl with capillaries of differing size. (From T. Suter, T. Peter, H. Bohni. Mater. Sci. Forum, 192-194, 25 (1995).)...
NaNs content. c)Drop 60 1 of stock soln B(10% in excess) from a 1000 1 storage tank to the stainless steel measuring tank of ca 100 1 capacity, where the soln is heated by means of hot water coils. Drop the preheated soln into the precipitator (reactor). [Pg.548]

Table 3. Tritium in TRA RPV Steel measured by NAA and Radiochemical Analysis... Table 3. Tritium in TRA RPV Steel measured by NAA and Radiochemical Analysis...
For a number of stress corrosion cracking systems, e.g., mild steel, austenitic stainless steels, measured bare surface current densities appear to be of the right order of magnitude ( ). For other alloys, e.g.,... [Pg.341]

Figure 7.18 Two-dimensional representation of the iR drop through concrete.While the CP current is flowing, the voltmeter between the reference electrode and the steel measures the steel/concrete potential plus the iR dropVn which is a function of the CP voltage Vcp and the resistances between anode, reference electrode and steel. Figure 7.18 Two-dimensional representation of the iR drop through concrete.While the CP current is flowing, the voltmeter between the reference electrode and the steel measures the steel/concrete potential plus the iR dropVn which is a function of the CP voltage Vcp and the resistances between anode, reference electrode and steel.
Figure 8. Friction coefficients against normal load for MeC H, TiN, TiAlN and steel measured against ball bearing steel under ambient conditions (up to about 50% relative humidity). Figure 8. Friction coefficients against normal load for MeC H, TiN, TiAlN and steel measured against ball bearing steel under ambient conditions (up to about 50% relative humidity).
Table la.25 High cycle fatigue strength of hip endoprostheses of stainless steel, measured in 0.9% NaCl solution at 37°C. Testing conditions according to DIN 58840 (simulation of a loosened shaft) (Ref. 19)... [Pg.162]

Figure 7.61 Normal probability plot of the pitting potentials of different ferritic stainless steels measured by potentiodynamic polarization in 3.5% NaCl at 30 °C under nitrogen atmosphere. Potential scan rate 16.7 mV min" [23]. Figure 7.61 Normal probability plot of the pitting potentials of different ferritic stainless steels measured by potentiodynamic polarization in 3.5% NaCl at 30 °C under nitrogen atmosphere. Potential scan rate 16.7 mV min" [23].
Molten Steel, Measurement of Dissolved Oxygen, Fig.1 Cross section of a steel probe for dissolved oxygen (schematically)... [Pg.1321]

In the same figure conader an element of the bolting steel measured by angle dO. The area of this element is given by ... [Pg.187]

The SFA is shown schematically in Figure 20.1. This instrument exists in many versions (44, 47-49). The interacting surfaces are enclosed in a stainless steel measuring chamber, the volume of which varies between 400 and 10 ml, depending on which version and which attachment is used. In case there is the need to use very small volumes one may simply place a droplet (V % 50 il) of the solution between the two surfaces. The latter method is preferable when working with turbid solutions, such as emulsions (50). However, a drawback with the droplet method is that the measurements... [Pg.385]

Figure 20.2. A schematic of the MASIF apparatus. One surface is mounted at the end of a bimorph force sensor and the other is mounted at the end of a piezo-electric tube actuator. The force sensor is enclosed in a Teflon sheath mounted inside the small stainless-steel measuring chamber (volume 10 ml). The LVDT displacement sensor is used to directly measure the displacement of the upper surface during force measurements... Figure 20.2. A schematic of the MASIF apparatus. One surface is mounted at the end of a bimorph force sensor and the other is mounted at the end of a piezo-electric tube actuator. The force sensor is enclosed in a Teflon sheath mounted inside the small stainless-steel measuring chamber (volume 10 ml). The LVDT displacement sensor is used to directly measure the displacement of the upper surface during force measurements...
Figure 7-30. Comparison of differently measured polarization curves of 5000 h aged duplex stainless steel measured in 0.1 M H2SO4 + 0.01 M KSCN. (a) Integral measurement of the aged material by the potentiostat SVE measurement of (b) austenite grain (c) ferrite grain (d) another ferrite grain (Jiang et al., 1992)... Figure 7-30. Comparison of differently measured polarization curves of 5000 h aged duplex stainless steel measured in 0.1 M H2SO4 + 0.01 M KSCN. (a) Integral measurement of the aged material by the potentiostat SVE measurement of (b) austenite grain (c) ferrite grain (d) another ferrite grain (Jiang et al., 1992)...

See other pages where Steel measurements is mentioned: [Pg.170]    [Pg.143]    [Pg.176]    [Pg.548]    [Pg.69]    [Pg.252]    [Pg.305]    [Pg.176]    [Pg.960]    [Pg.225]    [Pg.1114]    [Pg.71]    [Pg.200]    [Pg.388]    [Pg.191]    [Pg.79]    [Pg.309]    [Pg.323]    [Pg.476]    [Pg.485]    [Pg.1320]    [Pg.1320]    [Pg.1321]    [Pg.1989]    [Pg.385]    [Pg.385]    [Pg.1202]   
See also in sourсe #XX -- [ Pg.50 ]




SEARCH



© 2024 chempedia.info