Source-based noise control

Two UV detectors are also available from Laboratory Data Control, the UV Monitor and the Duo Monitor. The UV Monitor (Fig.3.45) consists of an optical unit anda control unit. The optical unit contains the UV source (low-pressure mercury lamp), sample, reference cells and photodetector. The control unit is connected by cable to the optical unit and may be located at a distance of up to 25 ft. The dual quartz flow cells (path-length, 10 mm diameter, 1 mm) each have a capacity of 8 (i 1. Double-beam linear-absorbance measurements may be made at either 254 nm or 280 nm. The absorbance ranges vary from 0.01 to 0.64 optical density units full scale (ODFS). The minimum detectable absorbance (equivalent to the noise) is 0.001 optical density units (OD). The drift of the photometer is usually less than 0.002 OD/h. With this system, it is possible to monitor continuously and quantitatively the absorbance at 254 or 280 nm of one liquid stream or the differential absorbance between two streams. The absorbance readout is linear and is directly related to the concentration in accordance with Beer s law. In the 280 nm mode, the 254-nm light is converted by a phosphor into a band with a maximum at 280 nm. This light is then passed to a photodetector which is sensitized for a response at 280 nm. The Duo Monitor (Fig.3.46) is a dual-wavelength continuous-flow detector with which effluents can be monitored simultaneously at 254 nm and 280 nm. The system consists of two modules, and the principle of operation is based on a modification of the 280-nm conversion kit for the UV Monitor. Light of 254-nm wavelength from a low-pressure mercury lamp is partially converted by the phosphor into a band at 280 nm. [Pg.89]


See other pages where Source-based noise control is mentioned: [Pg.163]    [Pg.127]    [Pg.151]    [Pg.108]    [Pg.199]    [Pg.222]    [Pg.41]    [Pg.127]    [Pg.198]    [Pg.34]    [Pg.199]    [Pg.133]    [Pg.29]    [Pg.138]    [Pg.125]    [Pg.133]    [Pg.229]    [Pg.335]    [Pg.738]    [Pg.117]    [Pg.2]    [Pg.398]    [Pg.388]    [Pg.452]    [Pg.1253]    [Pg.40]    [Pg.108]    [Pg.1885]    [Pg.759]    [Pg.241]    [Pg.450]    [Pg.249]    [Pg.129]    [Pg.3118]    [Pg.3121]    [Pg.3774]    [Pg.3897]    [Pg.128]    [Pg.160]    [Pg.100]    [Pg.553]    [Pg.198]    [Pg.305]   
See also in sourсe #XX -- [ Pg.1300 ]




SEARCH



Noise control

Noise sources

© 2024 chempedia.info