Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Solenoid dimensions

For the solenoid dimensions, D, r and d, we can use Conformability Analysis (CA) to predict the standard deviations based on a shifted distribution, a, which provides the largest estimate (or worst case) anticipated during a production run. Given that the dimension Z) = 012 0.03 mm is turned, the material to process risk can be shown to be = 1.2, and the geometry to process risk, g = 1. An adjusted tolerance is then given by ... [Pg.206]

The 6 mm end seal dimension wiii be used in the anaiysis, not 28 mm Figure 3.6 Solenoid end assembly design... [Pg.122]

The development of microcoil techniques has been reviewed by Minard and Wind [24, 25] and by Webb [26]. In a more recent publication Seeber et al. reported the design and testing of solenoidal microcoils with dimensions of tens to hundreds of microns [27]. For the smallest receiver coils these workers achieved a sensitivity that was sufficient to observe proton NMR with an SNR of unity in a single scan of 10 pm3 (10 fL) of water, containing 7 x 1011 proton spins. Reducing the diameter of the coil from millimeters to hundreds of microns thus increases its sensitivity greatly, allowing analysis of pL to pL sample volumes. [Pg.130]

The first task in a Noack-Schweikert magnet design is to define the best initial set of parameters and constraints, such as the number and dimensions of individual solenoids (layers), the maximum electrical power to be used, and the best materials. To define these parameters, one must consider numerous limitations arising from the manufacturing technology as well as the performance characteristics of the cooling system, and of the power... [Pg.416]

Finally, recall that subtraction of (5.2.1b) from (5.2.1a) yields, taking into account (5.2.1c) and (5.2.5a), ix = 0 (this corresponds to solenoidality of the total current density vector in more than one dimension). [Pg.163]

For solenoidal RF coils (see Figure 7.3.1.1(b)), the theoretical relationship between sensitivity and coil dimensions is given by the following ... [Pg.224]

Know the properties of chromatin components and its organization nucleosomes, histones, link DNA, and solenoids. Know the dimensions of the various chromatin components. Under-... [Pg.263]

Vector fields whose divergence vanishes are sometimes referred to as solenoidal. A more comprehensive discussion of the conditions for approximating the velocity field as solenoidal has been given by Batchelor.8 These imply that, in cases in which the fluid is subjected to an oscillating pressure, the characteristic velocity in the Mach number condition should be interpreted as the product of the frequency times the linear dimension of the fluid domain, and that the difference in static pressures over the length scale of the domain must be small compared with the absolute pressure. Because our subject matter will frequently deal with incompressible, isothermal fluids, we shall often make use of (2-20) in lieu of the... [Pg.24]

The performance of the spectrometer is impacted by changes in the dimensions of the radiofrequency coil. The signal-to-noise ratio (S/N) of an NM R experiment is increased by decreasing the size of the radiofrequency coil. Decreasing the size of the receiver coil results in increasing the S/N ratio since this ratio is proportional to the inverse of the coil diameter (for saddle and solenoid geometries). This functionality holds until the diameter of the coil is approximately 100 pm and... [Pg.241]

This relay is built in-house, using a solenoid connected to a switch mechanism with an 8 cm gap when open. Attention to safety is extremely important, as a power supply which can deliver as much as 30 KVolts is used in this system. The other end of the capillary is dipped into a buffer reservoir in which the electrode is connected through an ammeter to ground. Electrical currents in CZE depend on capillary dimensions, buffer conductivity and applied potential, but typical operating currents are between 10 and 100 microamps. [Pg.185]

NbsSn filament conductors are generally fabricated by means of a solid-state diffusion process ( ). In this the niobium rods are placed into a bronze matrix and jointly extruded. Once the final dimension is attained, the wire is subjected to heat treatment upon which tin selectively diffuses from the copper-tin matrix into niobium. This process is often executed after solenoid winding since the heat-treated wire can only to a limited extent be mechanically deformed. [Pg.11]

The Chandrasekhar-Hulm model leads to a unique Ivi Hm) curve, shown in Fig. 2, for all coils wound with identical wire type and insulation dimensions, since K and G(//), and therefore from (5), Id H) are the same for all these coils. Solenoids with an identical load factor, O = <21 (a,j3), should display identical critical currents Im and critical fields Hnti and this yields a criterion for an experimental check of the model. [Pg.317]


See other pages where Solenoid dimensions is mentioned: [Pg.469]    [Pg.537]    [Pg.83]    [Pg.8]    [Pg.73]    [Pg.38]    [Pg.272]    [Pg.552]    [Pg.413]    [Pg.414]    [Pg.173]    [Pg.227]    [Pg.229]    [Pg.231]    [Pg.266]    [Pg.323]    [Pg.212]    [Pg.417]    [Pg.288]    [Pg.192]    [Pg.386]    [Pg.460]    [Pg.167]    [Pg.316]    [Pg.212]    [Pg.168]    [Pg.164]    [Pg.136]    [Pg.4946]    [Pg.145]    [Pg.446]    [Pg.1139]    [Pg.331]    [Pg.158]    [Pg.164]    [Pg.50]   
See also in sourсe #XX -- [ Pg.387 ]




SEARCH



Solenoid

Solenoidal

© 2024 chempedia.info