Single-voxel technique

Fig. 12. Sequences for volume selective single voxel spectroscopy. Both techniques work with three slice-selective RF-pulses. (a) The Point RESolved Spectroscopy (PRESS) sequence generates a volume selective double spin-echo. The entire time delay between the initial 90° excitation and the echo is sensitive to transverse relaxation, (b) The Stimulated Echo Acquisition Mode (STEAM) sequence generates a stimulated echo. Maximal signal intensity (without relaxation effects) is only half the signal intensity of PRESS under comparable conditions, but slice profiles are often better (only 90° pulses instead of 180° pulses) and the TM interval is not susceptible to transverse relaxation, (c) The recorded echo signal is only generated in a volume corresponding to the intersection of all three slices. Fig. 12. Sequences for volume selective single voxel spectroscopy. Both techniques work with three slice-selective RF-pulses. (a) The Point RESolved Spectroscopy (PRESS) sequence generates a volume selective double spin-echo. The entire time delay between the initial 90° excitation and the echo is sensitive to transverse relaxation, (b) The Stimulated Echo Acquisition Mode (STEAM) sequence generates a stimulated echo. Maximal signal intensity (without relaxation effects) is only half the signal intensity of PRESS under comparable conditions, but slice profiles are often better (only 90° pulses instead of 180° pulses) and the TM interval is not susceptible to transverse relaxation, (c) The recorded echo signal is only generated in a volume corresponding to the intersection of all three slices.
Although ECVT is a promising non-intrusive technique, this system is limited to measuring bubbles greater than the voxel resolution. A bubble smaller than the voxel resolution cannot be measured by the ECVT. A potential solution to this issue is to increase the number of sensor electrodes and modify the related sensitivity which could increase the resolution to track the smaller, single bubble. [Pg.194]


See other pages where Single-voxel technique is mentioned: [Pg.123]    [Pg.123]    [Pg.953]    [Pg.118]    [Pg.42]    [Pg.48]    [Pg.77]    [Pg.391]    [Pg.502]    [Pg.509]    [Pg.390]    [Pg.366]    [Pg.275]    [Pg.119]    [Pg.402]    [Pg.48]    [Pg.397]    [Pg.176]    [Pg.3417]    [Pg.3423]    [Pg.3424]    [Pg.28]    [Pg.256]    [Pg.381]    [Pg.47]    [Pg.22]    [Pg.851]    [Pg.163]    [Pg.514]    [Pg.57]    [Pg.410]   
See also in sourсe #XX -- [ Pg.123 ]




SEARCH



Voxel

Voxels

© 2024 chempedia.info