Schematic diagram potentiostat

Schematic diagram of a manual potentiostat C = counter electrode ... Schematic diagram of a manual potentiostat C = counter electrode ...
Schematic diagram of a manuai potentiostat SW = siide-wire resistor A = auxiiiary eiectrode R = reference eiectrode W = working eiectrode ... Schematic diagram of a manuai potentiostat SW = siide-wire resistor A = auxiiiary eiectrode R = reference eiectrode W = working eiectrode ...
FIGURE 4-3 Schematic diagram of a three-electrode potentiostat. [Pg.105]

Figure 13. Schematic diagram of the measurement of the ionic conductivity of a conducting polymer membrane as a function of oxidation state (potential), (a) Pt electrodes (b) potentiostat (c) gold minigrid (d) polymer film (e) electrolyte solution (0 dc or ac resistance measurement.133 (Reprinted with permission from J. Am Chem Soc. 104, 6139-6140, 1982. Copyright 1982, American Chemical Society.)... Figure 13. Schematic diagram of the measurement of the ionic conductivity of a conducting polymer membrane as a function of oxidation state (potential), (a) Pt electrodes (b) potentiostat (c) gold minigrid (d) polymer film (e) electrolyte solution (0 dc or ac resistance measurement.133 (Reprinted with permission from J. Am Chem Soc. 104, 6139-6140, 1982. Copyright 1982, American Chemical Society.)...
Fig. 18b.1. Electrochemical cells and representative cell configurations, (a) Schematic diagram of a cell-potentiostat system, (b) Typical laboratory cell with Hg-drop electrode and drop knocker, (c) Voltammetric cell as detector at the end of a high-performance liquid chromatographic column, (d) A two-electrode (graphite) chip cell for biosensor development, (e) Three-electrode chip cells on a ceramic substrate for bioanalytical work. Fig. 18b.1. Electrochemical cells and representative cell configurations, (a) Schematic diagram of a cell-potentiostat system, (b) Typical laboratory cell with Hg-drop electrode and drop knocker, (c) Voltammetric cell as detector at the end of a high-performance liquid chromatographic column, (d) A two-electrode (graphite) chip cell for biosensor development, (e) Three-electrode chip cells on a ceramic substrate for bioanalytical work.
Figure 6.21. Schematic diagram of apparatus for potentiostatic measurements E, controlled potential ei, test electrode e2, reference electrode e3 counter (auxiliary)-electrode. Figure 6.21. Schematic diagram of apparatus for potentiostatic measurements E, controlled potential ei, test electrode e2, reference electrode e3 counter (auxiliary)-electrode.
Fig. 36.1. Schematic diagram of the three-electrode potentiostatic system. Reprinted from Ref. [1], Copyright 2005, with permission from Elsevier. Fig. 36.1. Schematic diagram of the three-electrode potentiostatic system. Reprinted from Ref. [1], Copyright 2005, with permission from Elsevier.
Figure 1 shows a schematic diagram of the basic SECM instrument employing an amperometric microprobe. An UME tip is attached to a three-dimensional (3D) piezo positioner controlled by a computer, which is also used for data acquisition. A bipotentiostat (i.e., a four-electrode potentiostat) controls the potentials of the tip and/or the substrate versus the reference electrode and... [Pg.179]

Flgure 7. Schematic diagram of the cell and current distribution with one (iK = 1a = 0) two (Ik 0 and iA = 0), or three (Ik 0 and 0) electrical circuits. A, ammeter P, potentiostat V, power supply a, porous working electrode b, auxiliary counterelectrode c, porous insulator d, fritted glass separator Er, reference electrode, electrode flow circuit, i ed = k v io = 1a + iv (Reprinted from Ref. 67 by permission of Chapman and Hall.)... [Pg.235]

Figure 8.7.5 Schematic diagram of apparatus employed for the temperature-jump method. The laser pulse is passed through a neutral density filter (ND) and irradiates the thin film electrode at the bottom of the cell. The dark rectangles are an auxiliary electrode and a QRE for measurement of the potential change. The potentiostat (Pot.), which adjusts the electrode potential before irradiation, is disconnected immediately before the laser pulse. The change in potential is measured with a fast amplifier (Amp.). [Reprinted from J. F. Smalley, L. Geng, S. W. Feldberg, L. C. Rogers, and J. Leddy, J. Electroanal. Chem., 356, 181 (1993), with permission from Elsevier Science.]... Figure 8.7.5 Schematic diagram of apparatus employed for the temperature-jump method. The laser pulse is passed through a neutral density filter (ND) and irradiates the thin film electrode at the bottom of the cell. The dark rectangles are an auxiliary electrode and a QRE for measurement of the potential change. The potentiostat (Pot.), which adjusts the electrode potential before irradiation, is disconnected immediately before the laser pulse. The change in potential is measured with a fast amplifier (Amp.). [Reprinted from J. F. Smalley, L. Geng, S. W. Feldberg, L. C. Rogers, and J. Leddy, J. Electroanal. Chem., 356, 181 (1993), with permission from Elsevier Science.]...
Figure 10. Schematic diagram of ohmic drop compensation by the positive feed-back technique in potentiostatic mode. Figure 10. Schematic diagram of ohmic drop compensation by the positive feed-back technique in potentiostatic mode.
Figure 1 is a schematic diagram of a basic electrochemical flow-deposition system used for electrodepositing thin films using EC-ALE, and Fig. 2 is a picture showing the solution reservoirs, pumps, valves, electrochemical cell, potentiostat, and computer. A number of elechochemical cell designs have been tried. A larger thin-layer electrochemical flow cell is now used (Fig. 3c) [40], with a deposition area of about 2.5 cm and a cell volume of 0.1 mL, resulting in a two order of magnitude drop in solution volume, compared with the H-cell (Fig. 3b). The cell includes an indium tin oxide (ITO) auxiliary electrode, as the opposite wall of the cell from... Figure 1 is a schematic diagram of a basic electrochemical flow-deposition system used for electrodepositing thin films using EC-ALE, and Fig. 2 is a picture showing the solution reservoirs, pumps, valves, electrochemical cell, potentiostat, and computer. A number of elechochemical cell designs have been tried. A larger thin-layer electrochemical flow cell is now used (Fig. 3c) [40], with a deposition area of about 2.5 cm and a cell volume of 0.1 mL, resulting in a two order of magnitude drop in solution volume, compared with the H-cell (Fig. 3b). The cell includes an indium tin oxide (ITO) auxiliary electrode, as the opposite wall of the cell from...
Figure 1. A schematic diagram (a) and a partial equivalent circuit (b) are given for the LAPS. The components 4, Ci, Cdf Re, Vref and Vchem, respectively represent the applied bias potential, the insulator and depletion layer capacitances, the electrolyte resistance, the potential across the reference electrode, and a chemically sensitive surface potential. Ip represents the photogeneration of hole-electron pairs, and I the measured alternating photocurrent. Solution potential is maintained by a potentiostat using a Pt controlling electrode (CTL) and Ag/AgCl reference electrode (REF). The potential is defined as the potential from the output of the reference electrode to ground. Figure 1. A schematic diagram (a) and a partial equivalent circuit (b) are given for the LAPS. The components 4, Ci, Cdf Re, Vref and Vchem, respectively represent the applied bias potential, the insulator and depletion layer capacitances, the electrolyte resistance, the potential across the reference electrode, and a chemically sensitive surface potential. Ip represents the photogeneration of hole-electron pairs, and I the measured alternating photocurrent. Solution potential is maintained by a potentiostat using a Pt controlling electrode (CTL) and Ag/AgCl reference electrode (REF). The potential is defined as the potential from the output of the reference electrode to ground.
Fig. II.6.1 Schematic diagram of a spectroelectrochemical system with a conventional three-electrode electrochemical cell WE working electrode, RE reference electrode, CE counter electrode) controlled by a computer-based potentiostat... Fig. II.6.1 Schematic diagram of a spectroelectrochemical system with a conventional three-electrode electrochemical cell WE working electrode, RE reference electrode, CE counter electrode) controlled by a computer-based potentiostat...
Fig. 3.15 Schematic diagram of a frequency response analyzer (FRA), showing the proper connections to the potentiostat for impedance spectroscopy and Mott-Schottky measurements. The function of the quasi-reference electrode is explained in Sect. 3.6.5... Fig. 3.15 Schematic diagram of a frequency response analyzer (FRA), showing the proper connections to the potentiostat for impedance spectroscopy and Mott-Schottky measurements. The function of the quasi-reference electrode is explained in Sect. 3.6.5...
Fig. 5.4 Schematic diagram of the CE-ECL detection system equipped with an electrically heating CPE. WE working electrode RE reference electrode CE counter electrode a the grounding of high-voltage power b, d connect to the function generator c connect to the potentiostat e the Ag/AgCl electrode /platinum wire. Reprinted with permission from Ref. [20]. Fig. 5.4 Schematic diagram of the CE-ECL detection system equipped with an electrically heating CPE. WE working electrode RE reference electrode CE counter electrode a the grounding of high-voltage power b, d connect to the function generator c connect to the potentiostat e the Ag/AgCl electrode /platinum wire. Reprinted with permission from Ref. [20].
Figure 7-2. Schematical diagram of electrochemical impedance measurements (Upper part) set-up with the electrochemical cell, the potentiostat, and the frequency response analyzer (FRA) (Lower part) potential perturbation A (f) and the current response A/(/) superimposed to the steady state point (E, 1 ) of the polarization curve. Figure 7-2. Schematical diagram of electrochemical impedance measurements (Upper part) set-up with the electrochemical cell, the potentiostat, and the frequency response analyzer (FRA) (Lower part) potential perturbation A (f) and the current response A/(/) superimposed to the steady state point (E, 1 ) of the polarization curve.
Obtained anodic potentiostatic curves of metals or alloys showing a passive state differ to a smaller or a greater degree from the presented schematic diagram. Characteristic quantities found on curves are strictly connected with the type (composition) of metal and environmental conditions. An increase of temperature usually significantly increases the j rn and values, while it only affects the change of the value to a small degree. [Pg.455]

Fig. 50. A schematic diagram of an automatic potentiostat A operational amplifier, D a large capacitor, Ri a measuring resistor. Fig. 50. A schematic diagram of an automatic potentiostat A operational amplifier, D a large capacitor, Ri a measuring resistor.
Fig. 70. A schematic diagram for the potential step method P potentiostat C three electrode cell R measuring resistor O oscilloscope. Fig. 70. A schematic diagram for the potential step method P potentiostat C three electrode cell R measuring resistor O oscilloscope.
Figure 1.11 (a) Controlled transport of myoglobin (NYO) across a conducting polymer membrane. Fast transport occurs when an electrical potential is applied to the pol5nner (0-A, B-C and D-E). Undetectable permeation occurs when no potential is applied (A-B, C-D and E-F). (b) Schematic diagram of the membrane transport cell. TTie membrane separates the stirred feed and receiving solutions and is connected to a galvanostat/potentiostat for control of the electrical potential and current. [Pg.29]

Figure 1. Schematic diagram illustrating Langmuir-Blodgett transfer under potentiostatic conditions. A gold-coated glass slide is acting as a working electrode in a three-electrode potentiostatic circuit. Below, an inset shows the pattern of the vapor deposited gold film. The central rectangular area (A = 0.20 cm ) is coated with an LB monolayer as the substrate is withdrawn from the subphase. The two lines mark the initial and the final position of the water meniscus in the LB experiments. Figure 1. Schematic diagram illustrating Langmuir-Blodgett transfer under potentiostatic conditions. A gold-coated glass slide is acting as a working electrode in a three-electrode potentiostatic circuit. Below, an inset shows the pattern of the vapor deposited gold film. The central rectangular area (A = 0.20 cm ) is coated with an LB monolayer as the substrate is withdrawn from the subphase. The two lines mark the initial and the final position of the water meniscus in the LB experiments.
Figure 9 is a schematic diagram of the apparatus for a transmission experiment. A typical experimental study proceeds as follows. Conventional electrochemical techniques (usually cyclic voltammetry) are used to establish the potentials where the processes of interest occur, e.g., adsorption and desorption potentials. The working electrode potential is then modulated between these values at a low frequency (typically 10 to 10 Hz) using a computer-controlled potentiostat. The choice of modulation frequency is not critical except, of course, it should be considerably less than the time constant... [Pg.25]

Fig. 19.38 Schematic polarisation from potentiostatic polarisation. B shows the negative loop and represents the cathodic reduction of dissolved oxygen. The dashed curves in the diagram are cathodic currents and are frequently drawn on the left-hand side of the E axis... Fig. 19.38 Schematic polarisation from potentiostatic polarisation. B shows the negative loop and represents the cathodic reduction of dissolved oxygen. The dashed curves in the diagram are cathodic currents and are frequently drawn on the left-hand side of the E axis...
Figure 28 Schematic Evans diagrams and polarization curves for a material in a solution containing a redox couple that acts as a chemical potentiostat. The i used in the Evans diagram for the O/R redox couple is that relevant to the material of interest. In the absence of the redox couple, the material obtains Ec, i. In the presence of the redox couple, the material obtains Econ2. If Econ2 is above the pitting potential, the material will be rapidly attacked. Figure 28 Schematic Evans diagrams and polarization curves for a material in a solution containing a redox couple that acts as a chemical potentiostat. The i used in the Evans diagram for the O/R redox couple is that relevant to the material of interest. In the absence of the redox couple, the material obtains Ec, i. In the presence of the redox couple, the material obtains Econ2. If Econ2 is above the pitting potential, the material will be rapidly attacked.

See other pages where Schematic diagram potentiostat is mentioned: [Pg.465]    [Pg.244]    [Pg.189]    [Pg.20]    [Pg.44]    [Pg.263]    [Pg.442]    [Pg.97]    [Pg.179]    [Pg.81]    [Pg.688]    [Pg.40]    [Pg.566]    [Pg.255]    [Pg.167]    [Pg.120]    [Pg.146]    [Pg.151]    [Pg.24]    [Pg.139]    [Pg.213]   
See also in sourсe #XX -- [ Pg.741 ]