Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Scheibel extractors

FIG. 15-45 Second Scheibel extractor with horizontal baffles and no wire-mesh packing between stages. [Reprinted with permission of Am. Inst. Chem. Eng. J., 2, 74 (1956)1... [Pg.1308]

Scatchard-Hildebrand equation, 374 Schacham equation, friction factor, 94 Scheibel extractor, 483,487 Schildknecht column, 543,544,546 Screens, separating, 335, 337 capacity, 335, 340 flat, 335... [Pg.754]

During the investigation of pollution in coastal seawaters, Werner and Waldichuk [24] pointed out the need for concentrating and isolating trace amounts of certain substances with a continuous solvent extractor. They constructed a modified Scheibel apparatus by changing the organic solvent cycle system. [Pg.367]

During recent years pilot scale equipment, smaller than the prototype pilot plants described and capable of operating with exceedingly high efficiency, has been designed. Such equipment as the York-Scheibel solvent extraction tower and the Podbielniak countercurrent centrifugal mixer and extractor are typical. Data from this equipment may be correlated with commercial performance. [Pg.195]

Mixer-settlers Scheibel columns Oldshue-Rushton column Rotating disk contractor (ROC) Asymmetric lotating disk extractor (ARC)... [Pg.597]

Figure 11 Agitated extractors. Left to right RDC, Karr, Oldshue-Rushton, Scheibel, Kuhni extraction columns. [Pg.333]

Rotating-Impeller Columns A number of different rotating-impeller column extractors have been proposed and built over the years. Only the Scheibel and Kiihni designs are reviewed here. For information about the Oldshue-Rushton design, see the previous edition of this handbook. Also see Oldshue, Chap. 13.4 in Handbook of... [Pg.1765]

FIG. 15-48 Scheibel column extractor (third-generation design). (Courtesy of Koch Modular Frocess Systems.)... [Pg.1769]

Countercurrent columns with additional kinetic energy input have found a broad range of industrial applications [42-48]. Examples of extraction towers with energy input are pulsed towers, pulsed packed columns and pulsed perforated-plate towers. A number of units with some form of mechanical agitation are also used (Karr column, Scheibel column, Oldshue-Rushton column, Ktihni column, RZE extractor, RDC and ARD extractor, Graesser contactor). [Pg.40]


See other pages where Scheibel extractors is mentioned: [Pg.482]    [Pg.482]    [Pg.510]    [Pg.482]    [Pg.482]    [Pg.1766]    [Pg.408]    [Pg.80]    [Pg.631]    [Pg.1760]    [Pg.736]    [Pg.482]    [Pg.482]    [Pg.510]    [Pg.482]    [Pg.482]    [Pg.1766]    [Pg.408]    [Pg.80]    [Pg.631]    [Pg.1760]    [Pg.736]    [Pg.1486]    [Pg.723]    [Pg.1111]    [Pg.485]    [Pg.1309]    [Pg.485]    [Pg.515]    [Pg.485]    [Pg.485]    [Pg.1701]    [Pg.1745]    [Pg.1745]    [Pg.1766]    [Pg.1767]    [Pg.411]    [Pg.15]    [Pg.59]    [Pg.59]    [Pg.80]    [Pg.81]   
See also in sourсe #XX -- [ Pg.483 , Pg.487 ]

See also in sourсe #XX -- [ Pg.483 , Pg.487 ]

See also in sourсe #XX -- [ Pg.483 , Pg.487 ]

See also in sourсe #XX -- [ Pg.483 , Pg.487 ]

See also in sourсe #XX -- [ Pg.483 , Pg.487 ]




SEARCH



Extractor

Solvent extraction Scheibel extractor