Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Scanning ion conductance microscope

Figure Bl.19.40. The scanning ion-conductance microscope (SICM) scans a micropipette over the contours of a surface, keepmg the electrical conductance tlirough the tip of the micropipette constant by adjusting the vertical height of the probe. (Taken from [211], figure 1.)... Figure Bl.19.40. The scanning ion-conductance microscope (SICM) scans a micropipette over the contours of a surface, keepmg the electrical conductance tlirough the tip of the micropipette constant by adjusting the vertical height of the probe. (Taken from [211], figure 1.)...
Flansma P K, Drake B, Marti O, Gould SAC and Prater C B 1989 The scanning ion-conductance microscope Science 243 641... [Pg.1730]

Membrane imaging techniques based on the measurement of the local solution conductivity using scanning ion conductance microscopes have also... [Pg.345]

Optical microscopy Phase contrast microscopy Polarized light microscopy Scanning electron microscopy Scanning ion conductance microscope Scanning probe microscopy Scanning thermal profiler... [Pg.380]

Schraml, S. Setup and Application of a Scanning Ion Conductance Microscope. Vienna University of Technology, Vienna 2003. [Pg.108]

Mann, S. Meyer, J. Dietzel, I., Integration of a scanning ion conductance microscope into phase contrast optics and its application to the quantification of morphological parameters of selected cells. Journal of Microscopy 2006, 224, 152-157. [Pg.109]

Korchev, Y Milovanovic, M. Bashford, C. Bennett, D. Sviderskaya, E. Vodyanoy, I. Lab, M., Specialized scanning ion-conductance microscope for imaging of living cells. Journal of Microscopy 1997,188,17-23. [Pg.113]

Membrane imaging techniques based on the measurement of the local solution conductivity using scanning ion conductance microscopes (SICM) have also been reported by Burnette and Ongpipattanakul, by Hansma et al., ° and more quantitatively by Baker group. A unique advantage of SECM relative to SICM is that the individual fluxes of different chemical species in a multicomponent solution may be determined by adjusting the electrochemical potential of the SECM tip to a value where the electroactive species of interest is reduced or oxidized. Since different chemical species have different electrochemical reduction potentials, it is possible to analyze for the individual membrane fluxes of several electroactive species in the same experiment. In addition, the use of selective SECM tips extends the SECM capabilities to the detection of fluxes of nonelectroactive species. [Pg.235]

Hasma PK, Dake B, Marti O, Gould SA, Prater CB (1989) The scanning ion conductance microscope. Science 243(4891) 641-643... [Pg.334]


See other pages where Scanning ion conductance microscope is mentioned: [Pg.643]    [Pg.353]    [Pg.1461]    [Pg.111]    [Pg.1719]    [Pg.271]    [Pg.35]    [Pg.107]    [Pg.427]    [Pg.51]    [Pg.314]    [Pg.630]   
See also in sourсe #XX -- [ Pg.35 ]




SEARCH



Ion conduction

Ion conductivity

Scanning ion conductance

Scanning microscope

© 2024 chempedia.info