Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Saturation spectroscopy apparatus

These problems can be somewhat overcome by a study of reactions in solution where much greater densities are possible than in the gas phase and fast bimolecular reaction are diffusion limited [1,28,29]. However, since coordinatively unsaturated metal carbonyls have shown a great affinity for coordinating solvent we felt that the appropriate place to begin a study of the spectroscopy and kinetics of these species would be in a phase where there is no solvent the gas phase. In the gas phase, the observed spectrum is expected to be that of the "naked" coordinatively unsaturated species and reactions of these species with added ligands are addition reactions rather than displacement reactions. However, since many of the saturated metal carbonyls have limited vapor pressures, the gas phase places additional constraints on the sensitivity of the transient spectroscopy apparatus. [Pg.87]

Characterization of catalysts The zeolite structure was checked by X-ray diffraction patterns recorded on a CGR Theta 60 instrument using Cu Ka, filtered radiation. The chemical composition of the catalysts was determined by atomic absorption analysis after dissolution of the sample (SCA-CNRS, Solaize, France). Micropore volumes were measured by N2 adsorption at 77 K using a Micromeritics ASAP 2000 apparatus and by adsorption of cyclohexane (at P/Po=0.15) using a microbalance apparatus SET ARAM SF 85. Incorporation of tetrahedral cobalt (II) in the framework of Co-Al-BEA and Co-B-BEA was confirmed by electronic spectroscopy [18] using a Perkin Elmer Lambda 14 UV-visible diffuse reflectance spectrophotometer. Acidity measurements were performed by Fourier transform infrared spectroscopy (FT-IR, Nicolet FTIR 320) after pyridine adsorption. Self-supported wafer of pure zeolite (20 mg/cm ) was outgassed at 673 K for 6 hours at a pressure of lO Pa. After cooling at 423 K, the zeolite was saturated with pyridine vapour (30 kPa) for 5 min, evacuated at this temperature for 30 min and the IR spectrum was recorded. [Pg.579]

Figure 4. Apparatus for saturated absorption spectroscopy of tritium. Figure 4. Apparatus for saturated absorption spectroscopy of tritium.
Fig. 1 Apparatus for Doppler-free saturated absorption spectroscopy in a gas sample. Fig. 1 Apparatus for Doppler-free saturated absorption spectroscopy in a gas sample.

See other pages where Saturation spectroscopy apparatus is mentioned: [Pg.458]    [Pg.179]    [Pg.74]    [Pg.82]    [Pg.155]    [Pg.224]    [Pg.148]    [Pg.417]    [Pg.476]    [Pg.347]    [Pg.237]    [Pg.258]    [Pg.427]   
See also in sourсe #XX -- [ Pg.56 ]




SEARCH



Saturated spectroscopy

Saturation spectroscopy

© 2024 chempedia.info