Sampling specific samplers

Permeation systems can be calibrated in the laboratory and then used in the field for sample collection for a fixed period of time, e.g., 8 hr or 7 days. The sampler is returned to the laboratory for analysis. These systems can be made for specific compounds by selecting the appropriate collection medium and the polymer membrane (Table 13-2). [Pg.191]

For HPLC, the injector is a valve. In the charge position, a 50- jL syringe is used to fill the sample loop that holds a specific volume of sample solution. The valve is switched to the run position, and the eluent carries the sample out of the sample loop and into the column (auto samplers are also available for HPLC). A recording of the detector output is automatically started at the time of injection and produces a chromatogram of the separated components. [Pg.281]

Similar to the previous section, we discuss only selected works to highlight the development of SPMDs. Also, we include some discussion of several unpublished pilot smdies (Huckins, 1989) that influenced our early development of SPMDs. These pilot studies were directed solely toward sampling the aqueous phase. The flrst application of SPMDs for sampling organic vapors did not occur until several years later (Petty et al., 1993). To our knowledge, only SPMDs, PESs and SPMEs are being applied in both air and water, because the use of many passive samplers is limited to a specific medium and exposure scenario. [Pg.17]

In 1995 Hewlett Packard introduced the HP 6890 series of instruments which are designed to fulfil a broad range of analytical requirements. TTiis series includes a specific automatic fiquid sampler for increased throughput and automation, a series of options for data-handhng/control for the gas chromatograph and samples, as well as an integrator that supports the fuU range of features provided. [Pg.120]

A universal sampler applicable to the majority of pesticides would be an ideal sampling device. In this study, personal sampling and analytical methods were developed and validated in the laboratory for determining workplace exposure to several pesticides. The major objectives of the study were to standardize on specific sampling media and to develop and validate methods using filter/ sorbent sampling trains. [Pg.301]

A colorimeter (Figure 4) has been designed specifically for analyzing >2/ ) passive samplers. It is lightweight, portable and simple to use. Features incorporated into the unit include a ten-minute timer with audible alarm to ensure complete color development of the samples before analysis, a cuvette slot which... [Pg.590]

Each of the passive and active samplers mentioned has a specific sampling rate. However, they do not reflect the respiration rate of an individual. For an estimate of the dose this respiration rate must be estimated from literature values or collection devices. [Pg.391]

After centrifugation, the specimens arc placed in a holder specifically designed to woik with a particular instrument. Once loaded, the sample holder is placed onto the carrier transport mechanism of the system, which is referred to as the sampler. The function of the sampler is to bring each specimen into a position where a sample of it can be taken by the aspiration probe, then to transport it further to the unloading area. [Pg.162]

The representation of the sampling by a unipolar, single-rotation-axis, U(l) sampler of a SU(2) continuous wave that is polarization/rotation-modulated is shown in Fig. 2, which shows the correspondence between the output space sphere and an Argand plane [28]. The Argand plane, S, is drawn in two dimensions, x and v, with z = 0, and for a set snapshot in time. A point on the Poincare sphere is represented as P(t,x,y,z), and as in this representation t = 1 (or one step in the future), specifically as P(l,x,y,z). The Poincare sphere is also identified as a 3-sphere, S 1, which is defined in Euclidean space as follows ... [Pg.713]


See other pages where Sampling specific samplers is mentioned: [Pg.975]    [Pg.31]    [Pg.25]    [Pg.173]    [Pg.9]    [Pg.107]    [Pg.306]    [Pg.908]    [Pg.909]    [Pg.916]    [Pg.925]    [Pg.930]    [Pg.982]    [Pg.1148]    [Pg.41]    [Pg.230]    [Pg.8]    [Pg.22]    [Pg.87]    [Pg.108]    [Pg.51]    [Pg.64]    [Pg.226]    [Pg.29]    [Pg.81]    [Pg.164]    [Pg.176]    [Pg.289]    [Pg.494]    [Pg.306]    [Pg.466]    [Pg.567]    [Pg.39]    [Pg.43]    [Pg.107]    [Pg.107]    [Pg.521]    [Pg.25]    [Pg.444]    [Pg.445]   
See also in sourсe #XX -- [ Pg.15 ]